Thermoeconomic performance analysis of different configurations of a combined ORC-VCR system using zeotropic mixtures

被引:3
|
作者
Xia, Xiaoxia [1 ]
Sun, Tong [1 ]
Wang, Zhiqi [1 ]
Liu, Zhipeng [1 ]
Zhang, Hualong [1 ]
Ju, ChengYuan [1 ]
机构
[1] Xiangtan Univ, Sch Mech Engn & Mech, Xiangtan 411105, Peoples R China
关键词
Organic Rankine cycle; Vapor compression refrigeration; System configuration; Zeotropic mixture; Thermoeconomic performance; ORGANIC RANKINE-CYCLE; VAPOR COMPRESSION CYCLE; HEAT; OPTIMIZATION; POWER; ENERGY;
D O I
10.1016/j.est.2023.108984
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
From the perspective of environmental protection, the application of new environment-friendly working fluids provides more feasibility for sustainable development. In addition, the improvement of system configuration increases the possibility of improving system performance. In this paper, the thermodynamic and economic performance model of the organic Rankine cycle (ORC)-vapor compression refrigeration (VCR) combined system is established. Four system configurations and 12 zeotropic mixtures on the system performance are researched and compared. The effect of operating parameters on system performance is studied. The results show that the recuperative-regenerative ORC-VCR (RR-ORC-VCR) system is confirmed as the optimal system configuration. Compared with the basic ORC-VCR (B-ORC-VCR) system, the coefficient of performance (COP) and exergy efficiency are improved by 14.65 % and 10.03 %, respectively. While the total cost increases by 6.85 %. The most suitable working fluid is R245fa/R1234yf (0.55/0.45). Higher glide temperature can be an important criterion in the selection of zeotropic mixtures. When the suction pressure ratio is 0.6, exergy efficiency and total cost are optimal, which are 11.95 % and 1.34 x 105$, respectively. While the highest COP with 0.73 is achieved when the suction pressure ratio is 0.65. With the increase of boiler temperature, the thermodynamic performance of the system increases obviously, but the economic performance decreases. The increase in condenser temperature has a negative impact on the system thermodynamic and economic performance. The growth of evaporator temperature is positively correlated with COP and negatively correlated with exergy efficiency and total cost.
引用
收藏
页数:18
相关论文
共 50 条
  • [41] Performance Analysis of a Thermoelectric Generation System with Different Flow Configurations
    Samarjeet Kumar
    Swaroop Kumar Mandal
    Purushottam Kumar Singh
    Santosh Kumar Mishra
    Alok Kumar Das
    Journal of Electronic Materials, 2019, 48 : 4607 - 4617
  • [42] Performance Analysis of a Thermoelectric Generation System with Different Flow Configurations
    Kumar, Samarjeet
    Mandal, Swaroop Kumar
    Singh, Purushottam Kumar
    Mishra, Santosh Kumar
    Das, Alok Kumar
    JOURNAL OF ELECTRONIC MATERIALS, 2019, 48 (07) : 4607 - 4617
  • [43] Exergoeconomic and exergoenvironmental analysis and optimization of an integrated double-flash-binary geothermal system and dual-pressure ORC using zeotropic mixtures; multi-objective optimization
    Chen, Ying
    Liu, Yuxuan
    Nam, Eun-Young
    Zhang, Yang
    Dahlak, Aida
    ENERGY, 2023, 283
  • [44] Performance enhancement of two-stage condensation combined cycle for LNG cold energy recovery using zeotropic mixtures
    Bao, Junjiang
    Lin, Yan
    Zhang, Ruixiang
    Zhang, Xiaopeng
    Zhang, Ning
    He, Gaohong
    ENERGY, 2018, 157 : 588 - 598
  • [45] Performance analysis of two stage combined heat pump system based on thermoeconomic optimization criterion
    Kodal, A
    Sahin, B
    Oktem, AS
    ENERGY CONVERSION AND MANAGEMENT, 2000, 41 (18) : 1989 - 1998
  • [46] Thermoeconomic analysis on the performance characteristics of a multi-stage irreversible combined heat pump system
    Chen, JC
    Wu, C
    JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME, 2000, 122 (04): : 212 - 216
  • [47] Carbon footprint analysis of organic rankine cycle system using zeotropic mixtures considering leak of fluid
    Wang, Shukun
    Liu, Chao
    Ren, Jingzheng
    Liu, Lang
    Li, Qibin
    Huo, Erguang
    JOURNAL OF CLEANER PRODUCTION, 2019, 239
  • [48] Thermodynamic performance of Kalina cycle system 11 (KCS11): feasibility of using alternative zeotropic mixtures
    Elsayed, Ahmed
    Embaye, Mebrahtu
    Al-Dadah, Raya
    Mahmoud, Saad
    Rezk, Ahmed
    INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2013, 8 (08) : I69 - I78
  • [49] Solar driven ORC-based CCHP: Comparative performance analysis between sequential and parallel system configurations
    Zhao, Li
    Zhang, Ying
    Deng, Shuai
    Ni, Jiaxin
    Xu, Weicong
    Ma, Minglu
    Lin, Shan
    Yu, Zhixin
    APPLIED THERMAL ENGINEERING, 2018, 131 : 696 - 706
  • [50] Exergoeconomic analysis and optimization of a novel integrated two power/cooling cogeneration system using zeotropic mixtures
    Mosaffa, A. H.
    Farshi, L. Garousi
    ENERGY, 2022, 253