Thermoeconomic performance analysis of different configurations of a combined ORC-VCR system using zeotropic mixtures

被引:3
|
作者
Xia, Xiaoxia [1 ]
Sun, Tong [1 ]
Wang, Zhiqi [1 ]
Liu, Zhipeng [1 ]
Zhang, Hualong [1 ]
Ju, ChengYuan [1 ]
机构
[1] Xiangtan Univ, Sch Mech Engn & Mech, Xiangtan 411105, Peoples R China
关键词
Organic Rankine cycle; Vapor compression refrigeration; System configuration; Zeotropic mixture; Thermoeconomic performance; ORGANIC RANKINE-CYCLE; VAPOR COMPRESSION CYCLE; HEAT; OPTIMIZATION; POWER; ENERGY;
D O I
10.1016/j.est.2023.108984
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
From the perspective of environmental protection, the application of new environment-friendly working fluids provides more feasibility for sustainable development. In addition, the improvement of system configuration increases the possibility of improving system performance. In this paper, the thermodynamic and economic performance model of the organic Rankine cycle (ORC)-vapor compression refrigeration (VCR) combined system is established. Four system configurations and 12 zeotropic mixtures on the system performance are researched and compared. The effect of operating parameters on system performance is studied. The results show that the recuperative-regenerative ORC-VCR (RR-ORC-VCR) system is confirmed as the optimal system configuration. Compared with the basic ORC-VCR (B-ORC-VCR) system, the coefficient of performance (COP) and exergy efficiency are improved by 14.65 % and 10.03 %, respectively. While the total cost increases by 6.85 %. The most suitable working fluid is R245fa/R1234yf (0.55/0.45). Higher glide temperature can be an important criterion in the selection of zeotropic mixtures. When the suction pressure ratio is 0.6, exergy efficiency and total cost are optimal, which are 11.95 % and 1.34 x 105$, respectively. While the highest COP with 0.73 is achieved when the suction pressure ratio is 0.65. With the increase of boiler temperature, the thermodynamic performance of the system increases obviously, but the economic performance decreases. The increase in condenser temperature has a negative impact on the system thermodynamic and economic performance. The growth of evaporator temperature is positively correlated with COP and negatively correlated with exergy efficiency and total cost.
引用
收藏
页数:18
相关论文
共 50 条
  • [32] Performance analysis of the partial evaporating organic Rankine cycle (PEORC) using zeotropic mixtures
    Zhou, Yaodong
    Zhang, Fengyuan
    Yu, Lijun
    ENERGY CONVERSION AND MANAGEMENT, 2016, 129 : 89 - 99
  • [33] Experimental investigation on the performance of ORC power system using zeotropic mixture R601a/R600a
    Wang, Yuping
    Liu, Xing
    Ding, Xiaoyi
    Weng, Yiwu
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2017, 41 (05) : 673 - 688
  • [34] Thermodynamic and economic analysis of ocean thermal energy conversion system using zeotropic mixtures
    Zhang, Yanmei
    Deng, Jiawei
    Deng, Zilong
    Case Studies in Thermal Engineering, 64
  • [35] Performance prediction, optimization and economic analysis of a combined PEMFC-ORC system
    Hamid Abdi
    Omar Ketfi
    Clement Ruvimbo Mapengo
    Noureddine Miri
    Journal of the Brazilian Society of Mechanical Sciences and Engineering, 2024, 46
  • [36] Performance prediction, optimization and economic analysis of a combined PEMFC-ORC system
    Abdi, Hamid
    Ketfi, Omar
    Mapengo, Clement Ruvimbo
    Miri, Noureddine
    JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2024, 46 (02)
  • [37] Comparative performance analysis of low-temperature Organic Rankine Cycle (ORC) using pure and zeotropic working fluids
    Aghahosseini, S.
    Dincer, I.
    APPLIED THERMAL ENGINEERING, 2013, 54 (01) : 35 - 42
  • [38] A new combined power and dual ejector refrigeration system using zeotropic mixtures with composition adjustable driven by geothermal resource: An exergoeconomic performance evaluation
    Mosaffa, A. H.
    GEOTHERMICS, 2023, 108
  • [39] Design and Performance Analysis of MIMO- OFDM System Using Different Antenna configurations
    Agarwal, Arun
    Mehta, Saurabh N.
    2016 INTERNATIONAL CONFERENCE ON ELECTRICAL, ELECTRONICS, AND OPTIMIZATION TECHNIQUES (ICEEOT), 2016, : 1373 - 1377
  • [40] Analysis of organic Rankine cycles using zeotropic mixtures as working fluids under different restrictive conditions
    Lu, Jinling
    Zhang, Jie
    Chen, Senlin
    Pu, Yaming
    ENERGY CONVERSION AND MANAGEMENT, 2016, 126 : 704 - 716