Reliability and applicability of a low-cost, camera-based gait evaluation method for clinical use

被引:7
|
作者
Spanos, Savvas [1 ,2 ,5 ]
Kanellopoulos, Asimakis [2 ,3 ]
Petropoulakos, Kyriakos [1 ]
Dimitriadis, Zacharias [2 ,3 ]
Siasios, Ioannis [4 ]
Poulis, Ioannis [1 ,2 ]
机构
[1] Univ Thessaly, Dept Physiotherapy, Human Performance & Rehabil Lab, Lamia, Greece
[2] Univ Thessaly, Sch Hlth Sci, Dept Physiotherapy, Lamia, Greece
[3] Univ Thessaly, Dept Physiotherapy, Hlth Assessment & Qual Life Lab, Lamia, Greece
[4] Papageorgiou Hosp, Dept Neurosurg, Thessaloniki, Greece
[5] Univ Thessaly, Dept Physiotherapy, Human Performance & Rehabil Lab, 3rd Km Old Natl Rd Lamia, Lamia 735100, Greece
关键词
Gait analysis; reliability; kinovea (R); kinematics; smartphone; CERVICAL MYELOPATHY; VALIDITY; MOTION; TIME; TOOL;
D O I
10.1080/17434440.2023.2171289
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: There is the need for the development of reliable and easy to use in clinical setting gait assessment tools. An open-access video analysis software that administers the calculation of kinematical and spatio-temporal characteristics of human movement is Kinovea (R) however, its repeatability as a gait analysis tool has not been well addressed. The purpose of the study was to examine the applicability and reliability of an objective, quantitative, low-cost and easy to use in the clinical setting, gait evaluation method, using Kinovea (R) software.Methods: Data collected from 44 healthy subjects recording gait in sagittal and frontal plane using two smartphones. Time consumption of the procedure was captured. Kinovea (R) software was used to calculate kinematical and spatial parameters.Results: Intra- and inter-rater reliability of the video processing as well as intra-rater reliability of the measurement procedure represented good to excellent and there were less random measurement errors. There was no measurement error due to random variation for the most of the calculated parameters, except of the pelvis position.Conclusions: The results suggest that excepting low accuracy in calculation of pelvis position, gait evaluation using Kinovea (R) software is objective, quantitative, low-cost, reliable and easy to use in the clinical setting.
引用
收藏
页码:63 / 70
页数:8
相关论文
共 50 条
  • [31] MICROCOMPUTER-BASED LOW-COST METHOD FOR MEASUREMENT OF SPATIAL AND TEMPORAL PARAMETERS OF GAIT
    LAW, HT
    JOURNAL OF BIOMEDICAL ENGINEERING, 1987, 9 (02): : 115 - 120
  • [32] Verification of gait analysis method fusing camera-based pose estimation and an IMU sensor in various gait conditions
    Masataka Yamamoto
    Koji Shimatani
    Yuto Ishige
    Hiroshi Takemura
    Scientific Reports, 12
  • [33] DEVELOPMENT AND EVALUATION OF A LOW-COST COTS-BASED CAMERA SYSTEM FOR SPACE APPLICATIONS
    Terakura, Masato
    Kogure, Hideaki
    Ohya, Kento
    Kimura, Shinichi
    SPACE FOR OUR FUTURE, 2013, 146 : 17 - 25
  • [34] Verification of gait analysis method fusing camera-based pose estimation and an IMU sensor in various gait conditions
    Yamamoto, Masataka
    Shimatani, Koji
    Ishige, Yuto
    Takemura, Hiroshi
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [35] Assay of prick test inoculum volume. I. Use and reliability of a gamma camera-based method
    Antico, A
    Lima, G
    Arisi, M
    Ostan, A
    Morrica, B
    ANNALS OF ALLERGY ASTHMA & IMMUNOLOGY, 2000, 85 (02) : 140 - 144
  • [36] Developing and Evaluating a Low-Cost Tracking Method based on a Single Camera and a Large Marker
    Rahchamani, Manizhe
    Soboute, Muhammad Ismail
    Samadzadehaghdam, Nasser
    MakkiAbadi, Bahador
    2018 25TH IRANIAN CONFERENCE ON BIOMEDICAL ENGINEERING AND 2018 3RD INTERNATIONAL IRANIAN CONFERENCE ON BIOMEDICAL ENGINEERING (ICBME), 2018, : 126 - 130
  • [37] Clinical reliability and validity of a video-based markerless gait evaluation method
    Lin, Jincong
    Wang, Yongtao
    Sha, Jia
    Li, Yi
    Fan, Zongzhi
    Lei, Wei
    Yan, Yabo
    FRONTIERS IN PEDIATRICS, 2023, 11
  • [38] A Mobile Camera-Based Evaluation Method of Inertial Measurement Units on Smartphones
    Middendorf, Lars
    Dorsch, Rainer
    Bichler, Rudolf
    Strohrmann, Christina
    Haubelt, Christian
    INTERNET OF THINGS: IOT INFRASTRUCTURES, IOT 360, PT II, 2016, 170 : 362 - 372
  • [39] Optomechanical design of a low-cost CCD-based camera
    Ahmad, A
    Arndt, T
    Bomber, R
    Perez, R
    Rodriguez, H
    Panasiti, M
    CURRENT DEVELOPMENTS IN LENS DESIGN AND OPTICAL SYSTEMS ENGINEERING, 2000, 4093 : 127 - 131
  • [40] A low-cost color interpolation method for CCD digital still camera
    Yang, Kai-Sheng
    Chen, Pei-Yin
    Chang, Chia-Wen
    Chang, Yu-Pin
    2007 IEEE INTERNATIONAL CONFERENCE ON INTEGRATED CIRCUIT DESIGN AND TECHNOLOGY, PROCEEDINGS, 2007, : 164 - +