Reliability and applicability of a low-cost, camera-based gait evaluation method for clinical use

被引:7
|
作者
Spanos, Savvas [1 ,2 ,5 ]
Kanellopoulos, Asimakis [2 ,3 ]
Petropoulakos, Kyriakos [1 ]
Dimitriadis, Zacharias [2 ,3 ]
Siasios, Ioannis [4 ]
Poulis, Ioannis [1 ,2 ]
机构
[1] Univ Thessaly, Dept Physiotherapy, Human Performance & Rehabil Lab, Lamia, Greece
[2] Univ Thessaly, Sch Hlth Sci, Dept Physiotherapy, Lamia, Greece
[3] Univ Thessaly, Dept Physiotherapy, Hlth Assessment & Qual Life Lab, Lamia, Greece
[4] Papageorgiou Hosp, Dept Neurosurg, Thessaloniki, Greece
[5] Univ Thessaly, Dept Physiotherapy, Human Performance & Rehabil Lab, 3rd Km Old Natl Rd Lamia, Lamia 735100, Greece
关键词
Gait analysis; reliability; kinovea (R); kinematics; smartphone; CERVICAL MYELOPATHY; VALIDITY; MOTION; TIME; TOOL;
D O I
10.1080/17434440.2023.2171289
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: There is the need for the development of reliable and easy to use in clinical setting gait assessment tools. An open-access video analysis software that administers the calculation of kinematical and spatio-temporal characteristics of human movement is Kinovea (R) however, its repeatability as a gait analysis tool has not been well addressed. The purpose of the study was to examine the applicability and reliability of an objective, quantitative, low-cost and easy to use in the clinical setting, gait evaluation method, using Kinovea (R) software.Methods: Data collected from 44 healthy subjects recording gait in sagittal and frontal plane using two smartphones. Time consumption of the procedure was captured. Kinovea (R) software was used to calculate kinematical and spatial parameters.Results: Intra- and inter-rater reliability of the video processing as well as intra-rater reliability of the measurement procedure represented good to excellent and there were less random measurement errors. There was no measurement error due to random variation for the most of the calculated parameters, except of the pelvis position.Conclusions: The results suggest that excepting low accuracy in calculation of pelvis position, gait evaluation using Kinovea (R) software is objective, quantitative, low-cost, reliable and easy to use in the clinical setting.
引用
收藏
页码:63 / 70
页数:8
相关论文
共 50 条
  • [21] Low-Cost Thermal Camera-Based Counting Occupancy Meter Facilitating Energy Saving in Smart Buildings
    Kraft, Marek
    Aszkowski, Przemyslaw
    Pieczynski, Dominik
    Fularz, Michal
    ENERGIES, 2021, 14 (15)
  • [22] Low-cost camera-based assessment of venous hemodynamics in the lower limbs: a study on young healthy volunteers
    Badiola, Idoia
    Seleng, Jan
    Silva, Diogo
    Blazek, Vladimir
    Leonhardt, Steffen
    Lueken, Markus
    Borik, Stefan
    BIOMEDICAL OPTICS EXPRESS, 2025, 16 (02): : 520 - 534
  • [23] Fast segment anything model applied in a low-cost camera-based system for oyster growth monitoring
    Batista, Vinicius
    Biazi, Vitorino
    Rodrigues, Andreia C. M.
    Soares, Amadeu M. V. M.
    Marques, Carlos
    AIP ADVANCES, 2024, 14 (12)
  • [24] Low-cost camera-based pulsed and modulated continuous wave laser detection for laser-based optical communications
    Tipper, Sean
    Burgess, Christopher
    OPTICAL ENGINEERING, 2021, 60 (12)
  • [25] Controlling First-Person Character Movement: A Low-Cost Camera-based Tracking Alternative for Virtual Reality
    Berriel, Rodrigo F.
    Paixao, Thiago M.
    Nicchio, Ivo
    Oliveira-Santos, Thiago
    2018 17TH BRAZILIAN SYMPOSIUM ON COMPUTER GAMES AND DIGITAL ENTERTAINMENT (SBGAMES 2018), 2018, : 67 - 74
  • [26] RGB-D Camera-based Navigation for Autonomous Underwater Inspection using Low-cost Micro AUVs
    Duecker, Daniel A.
    Hansen, Tim
    Kreuzer, Edwin
    2020 IEEE/OES AUTONOMOUS UNDERWATER VEHICLES SYMPOSIUM (AUV), 2020,
  • [27] Contrast gloss evaluation by use of a camera-based gloss meter
    Beuckels, Stijn
    Audenaert, Jan
    Leloup, Frederic B.
    Hanselaer, Peter
    UNCONVENTIONAL OPTICAL IMAGING III, 2022, 12136
  • [28] CONCURRENT VALIDITY AND RELIABILITY OF A LOW-COST GAIT ANALYSIS SYSTEM FOR ASSESSMENT OF SPATIOTEMPORAL GAIT PARAMETERS
    van Bloemendaal, Maijke
    Beelen, Anita
    Kleissen, Rob F. M.
    Geurts, Alexander C. H.
    Nollet, Frans
    Bus, Sicco A.
    JOURNAL OF REHABILITATION MEDICINE, 2019, 51 (06) : 456 - 463
  • [29] Development and Assessment of a Low-Cost Clinical Gait Analysis System
    Littrell, Mary Emily
    Chang, Young-Hui
    Selgrade, Brian P.
    JOURNAL OF APPLIED BIOMECHANICS, 2018, 34 (06) : 503 - 508
  • [30] Low-cost far infrared bolometer camera for automotive use
    Vieider, Christian
    Wissmar, Stanley
    Ericsson, Per
    Halldin, Urban
    Niklaus, Frank
    Stemme, Goeran
    Kallhammer, Jan-Erik
    Pettersson, Hakan
    Eriksson, Dick
    Jakobsen, Henrik
    Kvisteroy, Terje
    Franks, John
    VanNylen, Jan
    Vercammen, Hans
    VanHulsel, Annick