Validation and Development of a Method for Identification and Stability Analysis of Delafloxacin Separation Using LC-MS/MS

被引:0
|
作者
Sarbudeen, M. [1 ]
Abbaraju, V. D. N. Kumar [2 ]
Padmalatha, K. [3 ]
Kodali, Unati Sai [4 ]
Chinnamaneni, Satya Vani [5 ]
Mandava, Bhuvantej [6 ]
Rao, Mandava Venkata Basaveswarao [2 ]
机构
[1] Krishna Univ, Dept Chem, Machilipatnam 521004, Andhra Pradesh, India
[2] GITAM Univ, Dept Environm Sci, Visakhapatnam 521108, Andhra Pradesh, India
[3] Vijaya Inst Pharmaceut Sci Women, Vijayawada 521108, India
[4] Dr NTR Univ Hlth Sci, Dr Pinnamaneni Siddhartha Inst Med Sci & Res Fdn, Vijayawada, Andhra Pradesh, India
[5] Waters Corp, Principal QC Lab Tech, Milford, MA USA
[6] Sacred Heart Univ, Dept Healthcare informat, 5151 Pk Ave, Fair Fields, CT 06825 USA
关键词
LC-MS/MS; Validation; Linearity; Nano gram; MRM ion modeDelafloxacin; PLASMA;
D O I
10.13005/ojc/400112
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
In order todevelop and validate the technique for delafloxacin authors are used the peak intense which is furthermore improved to this present investigation employing a variety of parameters, which includes column, alteration of eluent ratio, and rate of flow. For this development authors are usedWaters column with 2.1mmx100mm, 5 mu m, C18. Mobile phase as 0.2% formic acid with pH of 2.6 and acetonitrile in the proportion of 30v/v:70v/v. The retention was 1.2 min and the rate of flow is identified as 0.12 mu L/minute. Forced degradation studies reveals that the peaksobtained are homogeneousand there are noco-elutingpeaks. The %RSD was found to be 3.5. Six LLOQ concentrations (10 ng/ml-1)of delafloxacin were evaluated in order to carry out the precision study. The results of calibration curve were 232.8, 0.9968, and 1273, respectivelyfor slope, coefficient of correlation (r2), and intercept.Mass spectrum development is done by the utilization of MRM ion mode (ES+) with mass transitions of m/z 441.10>379.10 (amu). On ionization,both parent and daughter ions were identified. 10-150 ng/mL is the calibration curve which reveals that linear by lower quantification limit of 10.00 ng/mL. LOQ- 50.00 ng/mL, MOQ-100.00 ng/mL, HOQ-150.00 ng/mL set to accuracy studies.In this present study, the research could be very helpful inlocating other potential DPs and process -related impurities that might be present indelafloxacin in very small amounts.
引用
收藏
页码:95 / 101
页数:7
相关论文
共 50 条
  • [41] Development of pretreatment method for analysis of fungicides and hormones in seawater using LC-MS/MS
    Muambo, Kimberly Etombi
    Moon, Haeran
    InSeok, Lee
    Oh, Jeong-Eun
    ENVIRONMENTAL ENGINEERING RESEARCH, 2023, 28 (05)
  • [42] LC-MS/MS method for pyrithroids analysis
    Cassias, Irene
    Chang, Eugene
    Wilson, Sarah
    Lane, Shannon
    Barrera, Trojan
    Blount, Janet
    Limson, Andrew
    Ajayi, Olusegun
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2014, 248
  • [43] LC-MS/MS Method Development for the Discovery and Identification of Amphidinols Produced by Amphidinium
    Wellkamp, Marvin
    Garcia-Camacho, Francisco
    Duran-Riveroll, Lorena M.
    Tebben, Jan
    Tillmann, Urban
    Krock, Bernd
    MARINE DRUGS, 2020, 18 (10)
  • [44] Method validation for plasma amino acids analysis utilizing LC-MS/MS
    Fallatah, N.
    Alomairi, S.
    Almutairi, M.
    Asiri, H.
    Asiri, Z.
    Alharbi, S.
    Alhumaid, A.
    Batel, H.
    CLINICA CHIMICA ACTA, 2024, 558
  • [45] Method validation and analysis of nine dithiocarbamates in fruits and vegetables by LC-MS/MS
    Schmidt, B.
    Christensen, H. B.
    Petersen, A.
    Sloth, J. J.
    Poulsen, M. E.
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2013, 30 (07): : 1287 - 1298
  • [46] Development and validation of an efficient and innovative method for the quantification of multiclass veterinary drugs in milk by using LC-MS/MS analysis
    Lopes, Renata Pereira
    Augusti, Daniella Vasconcellos
    Santos, Flavio Alves
    Vargas, Eugenia Azevedo
    Augusti, Rodinei
    ANALYTICAL METHODS, 2013, 5 (19) : 5121 - 5127
  • [47] LC-MS/MS characterization of the forced degradation products of ezetemibe: Development and validation of a stability -indicating UPLC method
    Kancherla, Prasad
    Velpuri, Venkatappaiah
    Alegete, Pallavi
    Albaseer, Saeed S.
    Khagga, Mukkanti
    Das, Parthasaradhi
    JOURNAL OF TAIBAH UNIVERSITY FOR SCIENCE, 2016, 10 (01): : 148 - 160
  • [48] Development and validation of a LC-MS/MS method for homocysteine thiolactone in plasma and evaluation of its stability in plasma samples
    Arora, Beauty
    Narayanasamy, Angayarkanni
    Nirmal, Jayabalan
    Halder, Nabanita
    Patnaik, Santosh
    Ravi, Alok K.
    Velpandian, Thirumurthy
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 944 : 49 - 54
  • [49] Method Development and Validation for Quantification of Quercetin in Blood Plasma of Wistar Rats Using LC-MS/MS
    Panda, Bhisma Narayan
    Gupta, Sapna
    Kumari, Premlata
    Singh, Ruchi
    Bhat, Binu
    Pramod, R. Kumar
    CURRENT PHARMACEUTICAL ANALYSIS, 2024,
  • [50] Development and Validation of an LC-MS/MS Method for the Ultra-Trace Analysis of Pacific Ciguatoxins in Fish
    Nagae, Mika
    Igarashi, Tomoji
    Mizukoshi, Kazushi
    Kuniyoshi, Kyoko
    Oshiro, Naomasa
    Yasumoto, Takeshi
    JOURNAL OF AOAC INTERNATIONAL, 2021, 104 (05) : 1272 - 1281