Validation and Development of a Method for Identification and Stability Analysis of Delafloxacin Separation Using LC-MS/MS

被引:0
|
作者
Sarbudeen, M. [1 ]
Abbaraju, V. D. N. Kumar [2 ]
Padmalatha, K. [3 ]
Kodali, Unati Sai [4 ]
Chinnamaneni, Satya Vani [5 ]
Mandava, Bhuvantej [6 ]
Rao, Mandava Venkata Basaveswarao [2 ]
机构
[1] Krishna Univ, Dept Chem, Machilipatnam 521004, Andhra Pradesh, India
[2] GITAM Univ, Dept Environm Sci, Visakhapatnam 521108, Andhra Pradesh, India
[3] Vijaya Inst Pharmaceut Sci Women, Vijayawada 521108, India
[4] Dr NTR Univ Hlth Sci, Dr Pinnamaneni Siddhartha Inst Med Sci & Res Fdn, Vijayawada, Andhra Pradesh, India
[5] Waters Corp, Principal QC Lab Tech, Milford, MA USA
[6] Sacred Heart Univ, Dept Healthcare informat, 5151 Pk Ave, Fair Fields, CT 06825 USA
关键词
LC-MS/MS; Validation; Linearity; Nano gram; MRM ion modeDelafloxacin; PLASMA;
D O I
10.13005/ojc/400112
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
In order todevelop and validate the technique for delafloxacin authors are used the peak intense which is furthermore improved to this present investigation employing a variety of parameters, which includes column, alteration of eluent ratio, and rate of flow. For this development authors are usedWaters column with 2.1mmx100mm, 5 mu m, C18. Mobile phase as 0.2% formic acid with pH of 2.6 and acetonitrile in the proportion of 30v/v:70v/v. The retention was 1.2 min and the rate of flow is identified as 0.12 mu L/minute. Forced degradation studies reveals that the peaksobtained are homogeneousand there are noco-elutingpeaks. The %RSD was found to be 3.5. Six LLOQ concentrations (10 ng/ml-1)of delafloxacin were evaluated in order to carry out the precision study. The results of calibration curve were 232.8, 0.9968, and 1273, respectivelyfor slope, coefficient of correlation (r2), and intercept.Mass spectrum development is done by the utilization of MRM ion mode (ES+) with mass transitions of m/z 441.10>379.10 (amu). On ionization,both parent and daughter ions were identified. 10-150 ng/mL is the calibration curve which reveals that linear by lower quantification limit of 10.00 ng/mL. LOQ- 50.00 ng/mL, MOQ-100.00 ng/mL, HOQ-150.00 ng/mL set to accuracy studies.In this present study, the research could be very helpful inlocating other potential DPs and process -related impurities that might be present indelafloxacin in very small amounts.
引用
收藏
页码:95 / 101
页数:7
相关论文
共 50 条
  • [21] Bioanalytical method development and validation of a novel antiseizure agent Cenobamate using LC-MS/MS
    Rao, Yamarthi Venkateswara
    Shaik, Rasheed Ahemad
    Chimakurthy, Jithendra
    INTERNATIONAL JOURNAL OF NANOTECHNOLOGY, 2023, 20 (1-4) : 63 - 74
  • [22] METHOD DEVELOPMENT AND VALIDATION FOR THE QUANTITATION OF TRIFLURIDINE IN HUMAN PLASMA BY USING LC-MS/MS TECHNIQUE
    Mohammad, Abdul Saleem
    Ahmad, Fazil
    Jayanthi, B.
    INTERNATIONAL JOURNAL OF PHARMACEUTICAL SCIENCES AND RESEARCH, 2020, 11 (07): : 3252 - 3259
  • [23] Method development and validation of testosterone in muscle by using LC-MS/MS in positive ESI mode
    Dahiya, Meenakshi
    Dubey, Nidhi
    Singh, Prabha
    Singh, G. N.
    INDIAN JOURNAL OF CHEMISTRY SECTION B-ORGANIC CHEMISTRY INCLUDING MEDICINAL CHEMISTRY, 2013, 52 (04): : 573 - 578
  • [24] Development and validation of a stability-indicating LC-UV and LC-MS/MS methods for quantitative analysis of anisomycin and identification of degradation products
    Tolic, Ljiljana
    Grujic, Svetlana
    Lausevic, Mila
    BRAZILIAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2018, 54 (02)
  • [25] Development and validation of a chiral LC-MS/MS method for the separation and quantification of four synthetic cathinones in human whole blood and its application in stability analysis
    Aldubayyan A.A.
    Castrignanò E.
    Elliott S.
    Abbate V.
    Talanta, 2023, 253
  • [26] Development and validation of a LC-MS/MS method for the determination of viaminate in human plasma
    Yin, Jing
    Ni, Kun-Yi
    Shen, Yue
    Ma, Peng-Cheng
    Cao, Ling
    Wang, Wei-Peng
    Wang, Yu
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 856 (1-2): : 376 - 380
  • [27] LC-MS/MS Method Development and Validation for the Determination of Nifedipine in Human Plasma
    Logoyda, Liliya S.
    BIOINTERFACE RESEARCH IN APPLIED CHEMISTRY, 2020, 10 (05): : 6220 - 6227
  • [28] Development and validation of an LC-MS/MS method for determination of methanesulfonamide in human urine
    Anacardio, Roberto
    Mullins, Frank G. P.
    Hannam, Sally
    Sheikh, Muhammed S.
    O'Shea, Karen
    Aramini, Andrea
    D'Anniballe, Gaetano
    D'Anteo, Loredana
    Ferrari, Mauro P.
    Allegretti, Marcello
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (22): : 2087 - 2092
  • [29] Development and validation of analytical method for Naftopidil in human plasma by LC-MS/MS
    Jain, Pritam S.
    Bobade, Kajal D.
    Bari, Pankaj R.
    Girase, Devendra S.
    Surana, Sanjay J.
    ARABIAN JOURNAL OF CHEMISTRY, 2015, 8 (05) : 648 - 654
  • [30] Bioanalytical Method Development and Validation of Metaxalone in Human Plasma by LC-MS/MS
    Soni, Nirav R.
    Patel, Mandev B.
    INTERNATIONAL JOURNAL OF PHARMACEUTICAL RESEARCH AND ALLIED SCIENCES, 2015, 4 (03): : 100 - 108