Immersion ultrasound improves the repeatability of shear-wave elastography for measuring median nerve elasticity

被引:2
|
作者
Zhang, Zhijun [1 ]
Wang, Hui [1 ]
Ding, Xiaoya [1 ]
He, Shu [2 ]
机构
[1] Chongqing Med Univ, Univ Town Hosp, Dept Ultrasound, Chongqing 401331, Peoples R China
[2] Fifth Peoples Hosp Chongqing, Med Affairs Dept, Chongqing 400030, Peoples R China
关键词
Shear wave elastography; Median nerve; Repeatability; POTENTIAL SONOGRAPHIC METHOD; DIAGNOSIS;
D O I
10.1186/s13018-023-04097-6
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
ObjectiveTo study the factors that influence the measurement of median nerve elasticity, to provide a more reproducible test for the assessment of median nerve elasticity using shear wave elasticity (SWE), and to reduce operator empirical dependence. To compare the repeatability of the median nerve elasticity measurement using immersion SWE with that using contact SWE, analyze the factors affecting SWE measurement, and provide a more repeatable method for doctors without SWE operation experience.MethodsTwo doctors without SWE operation experience measured the median nerve mean elastic modulus (Emean) at the same position and at different time points on the right wrist of 58 healthy volunteers using immersion and contact ultrasound methods. The intraobserver and interobserver repeatability of measurements was assessed using the interclass correlation coefficient (ICC), while the repeatability was assessed using the Bland-Altman diagram.ResultsThe intraobserver and interobserver repeatability of the median nerve elasticity measured via contact SWE by inexperienced operators were classified as good, with ICCs of 0.633 (95% CI 0.380-0.783) and 0.552 (95% CI 0.243-0.735), respectively. The intraobserver and interobserver repeatability of the median nerve elasticity measured by immersion SWE were very good, with ICCs of 0.975 (95% CI 0.958-0.985) and 0.942 (95% CI 0.902-0.966), respectively. The intraobserver and interobserver Bland-Altman diagram of median nerve elasticity measured by immersion SWE showed that 98% of the points fell within the 95% limits of agreement. The intraobserver and interobserver Bland-Altman diagram of median nerve elasticity measured by contact SWE showed that 94% of the points fell within the 95% limits of agreement.ConclusionImmersion ultrasound can improve the repeatability of median nerve elasticity measurements by inexperienced operators.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Assessment of thyroid gland elasticity with shear-wave elastography in Hashimoto’s thyroiditis patients
    Turgay Kara
    Fatih Ateş
    Mehmet Sedat Durmaz
    Nesibe Akyürek
    Funda Gökgöz Durmaz
    Bora Özbakır
    Mehmet Öztürk
    Journal of Ultrasound, 2020, 23 : 543 - 551
  • [42] Diagnostic value of median nerve shear wave ultrasound elastography in diagnosis and differentiation of carpal tunnel syndrome severity
    Heba Refaat Ibrahim
    Egyptian Journal of Radiology and Nuclear Medicine, 52
  • [43] Diagnostic value of median nerve shear wave ultrasound elastography in diagnosis and differentiation of carpal tunnel syndrome severity
    Ibrahim, Heba Refaat
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2021, 52 (01):
  • [44] SHEAR-WAVE MEASUREMENTS OF THE ELASTICITY OF THE GROUND
    ABBISS, CP
    GEOTECHNIQUE, 1981, 31 (01): : 91 - 104
  • [45] The evaluation of retrobulbar fat tissue in Graves' orbitopathy with shear-wave ultrasound elastography
    Gunes, Irfan Botan
    Yilmaz, Hakan
    Onal, Eda Demir
    INTERNATIONAL OPHTHALMOLOGY, 2024, 44 (01)
  • [46] Shear-wave versus strain elastography in endoscopic ultrasound for the diagnosis of chronic pancreatitis
    Yamashita, Yasunobu
    Yamazaki, Hirofumi
    Shimokawa, Toshio
    Kawaji, Yuki
    Tamumra, Takashi
    Hatamaru, Keiichi
    Itonaga, Masahiro
    Ashida, Reiko
    Kitano, Masayuki
    PANCREATOLOGY, 2023, 23 (01) : 35 - 41
  • [47] Ultrasound shear-wave elastography applicability in estimation of post-mortem time
    Mosadegh, Mohsen
    Khazaei, Mehdi
    Abdollahpour, Zohreh D.
    Alahyari, Sam
    Moharamzad, Yashar
    Emamhadi, Mohammadali
    Aram, Samira
    Abolbaghaei, Mojtaba
    Taheri, Morteza Sanei
    ULTRASOUND, 2022, 30 (02) : 134 - 140
  • [48] Shear-wave ultrasound elastography of the liver in normal-weight and obese children
    Bailey, Smita Sane
    Youssfi, Mostafa
    Patel, Mittun
    Hu, Houchun H.
    Shaibi, Gabriel Q.
    Towbin, Richard B.
    ACTA RADIOLOGICA, 2017, 58 (12) : 1511 - 1518
  • [49] Reliability of ultrasound shear-wave elastography in assessing tensor fascia latae, gluteus medius, and iliotibial band elasticity in health individuals
    Topaloglu, Mahir
    Turan, Zeynep
    Sarikaya, Deniz
    Taskiran, Ozden Ozyemisci
    CUKUROVA MEDICAL JOURNAL, 2024, 49 (03): : 632 - 638
  • [50] Shear wave elastography evaluation of the median and tibial nerve in diabetic peripheral neuropathy
    He, Ying
    Xiang, Xi
    Zhu, Bi-Hui
    Qiu, Li
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2019, 9 (02) : 273 - 282