Late Survival After Valve-in-Valve Transcatheter Aortic Valve Implantation With Balloon- Versus Self- Expandable Valves: Meta-Analysis of Reconstructed Time-to-Event Data

被引:1
|
作者
Sa, Michel Pompeu [1 ,2 ]
Jacquemyn, Xander [3 ]
Simonato, Matheus [4 ]
Brown, James A. [1 ,2 ]
Ahmad, Danial [1 ,2 ]
Serna-Gallegos, Derek [1 ,2 ]
Clavel, Marie-Annick [5 ,6 ]
Pibarot, Philippe [5 ,6 ]
Dvir, Danny [7 ,8 ]
Sultan, Ibrahim [1 ,2 ]
机构
[1] Univ Pittsburgh, Dept Cardiothorac Surg, Pittsburgh, PA 15260 USA
[2] Univ Pittsburgh, UPMC Heart & Vasc Inst, Med Ctr, Pittsburgh, PA 15260 USA
[3] Katholieke Univ Leuven, Dept Cardiovasc Sci, Leuven, Belgium
[4] Yale Sch Med, New Haven, CT USA
[5] Ctr Rech Inst Univ Cardiol & Pneumol Quebec, Quebec City, PQ, Canada
[6] Univ Laval, Fac Med, Dept Med, Quebec City, PQ, Canada
[7] Hebrew Univ Jerusalem, Shaare Zedek Med Ctr, Dept Cardiol, Jerusalem, Israel
[8] Hebrew Univ Jerusalem, Fac Med, Jerusalem, Israel
来源
关键词
aortic valve; cardiac surgical procedures; cardiovascular surgical procedures; heart valve prosthesis implantation; meta-analysis; transcatheter aortic valve replacement; REPLACEMENT;
D O I
10.1016/j.amjcard.2023.09.108
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Valve-in-valve (ViV) transcatheter aortic valve implantation (TAVI) in patients with failed bioprostheses arose as an alternative to redo surgical aortic valve replacement. There is an increasing interest in exploring the differences between self-expanding valves (SEVs) and balloon-expandable valves (BEVs). Our study aimed to evaluate the all-cause mortality in ViV-TAVI with SEV versus BEV in patients with failed bioprostheses. We performed a study-level meta-analysis of reconstructed time-to-event data from Kaplan -Meier curves of studies published by March 30, 2023. A total of 5 studies met our eligibil-ity criteria and included 1,454 patients who underwent ViV-TAVI (862 with SEV and 592 with BEV). Almost all BEVs were iterations of the Edwards BEVs (SAPIEN, SAPIEN XT, and SAPIEN 3) and almost all SEVs were iterations of the Medtronic SEVs (CoreValve/ Evolut). During the first year after ViV-TAVI, 67 deaths (11.8%) occurred in patients treated with BEV compared with 92 deaths (11.1%) in patients treated with SEV (hazard ratio 0.92, 95% confidence interval 0.66 to 1.27, p = 0.632). At 8 years of follow-up, the all-cause death was not statistically significantly different between the groups, with mortality rates of 65.4% in the group treated BEV and 58.8% in the group treated with SEV (hazard ratio 0.91, 95% confidence interval 0.75 to 1.09, p = 0.302). The restricted mean survival time was overall 0.25 years greater with SEV than BEV, but this difference was not statistically significant (p = 0.278), which indicates no lifetime gain or loss with SEV in comparison with BEV. There seems to be no difference in terms of all-cause death in ViV-TAVI with SEV versus BEV. Randomized controlled trials are warranted to validate our results.(c) 2023 Elsevier Inc. All rights reserved. (Am J Cardiol 2023;209:120-127)
引用
收藏
页码:120 / 127
页数:8
相关论文
共 50 条
  • [41] Valve-in-Valve Transcatheter Aortic Valve Replacement Versus Redo Surgical Aortic Valve Replacement An Updated Meta-Analysis
    Sa, Michel Pompeu B. O.
    Van den Eynde, Jef
    Simonato, Matheus
    Cavalcanti, Luiz Rafael P.
    Doulamis, Ilias P.
    Weixler, Viktoria
    Kampaktsis, Polydoros N.
    Gallo, Michele
    Laforgia, Pietro L.
    Zhigalov, Konstantin
    Ruhparwar, Arjang
    Weymann, Alexander
    Pibarot, Philippe
    Clavel, Marie-Annick
    JACC-CARDIOVASCULAR INTERVENTIONS, 2021, 14 (02) : 211 - 220
  • [42] Valve-in-valve transcatheter aortic valve implantation after failed surgically implanted aortic bioprosthesis versus native transcatheter aortic valve implantation for aortic stenosis: Data from a nationwide analysis
    Deharo, Pierre
    Bisson, Arnaud
    Herbert, Julien
    Lacour, Thibaud
    Saint Etienne, Christophe
    Jaussaud, Nicolas
    Theron, Alexis
    Collart, Frederic
    Bourguignon, Thierry
    Cuisset, Thomas
    Fauchier, Laurent
    ARCHIVES OF CARDIOVASCULAR DISEASES, 2021, 114 (01) : 41 - 50
  • [43] Asian Comparative Outcomes of Balloon-Expandable versus Self-expandable valves for Transcatheter Aortic Valve Implantation
    Yoon, Sung-Han
    Ahn, Jung-Min
    Lee, Michael Kang-Yin
    Tay, Edgar L.
    Kim, Young-Hak
    Lee, Cheol Whan
    Lee, Jong-Young
    Yang, Dong Hyun
    Kang, Joon-Won
    Choi, Hyo In
    Roh, Jae Hyung
    Lee, Pil Hyung
    Chang, Mineok
    Park, Hyun Woo
    Kang, Soo-Jin
    Park, Duk-Woo
    Lee, Seung-Whan
    Song, Jong-Min
    Park, Seong-Wook
    Park, Seung-Jung
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 64 (11) : B220 - B220
  • [44] Systematic review and meta-analysis of valve-in-valve transcatheter aortic valve replacement in patients with failed bioprosthetic aortic valves
    Mahmoud, Ahmed N.
    Gad, Mohamed M.
    Elgendy, Islam Y.
    Mahmoud, Ahmad A.
    Taha, Yasmeen
    Elgendy, Akram Y.
    Ahuja, Keerat R.
    Saad, Anas M.
    Simonato, Matheus
    McCabe, James M.
    Reisman, Mark
    Kapadia, Samir R.
    Dvir, Danny
    EUROINTERVENTION, 2020, 16 (07) : 539 - +
  • [45] Meta-analysis of transcatheter aortic valve implantation for bicuspid versus tricuspid aortic valves
    Takagi, Hisato
    Hari, Yosuke
    Kawai, Norikazu
    Kuno, Toshiki
    Ando, Tomo
    JOURNAL OF CARDIOLOGY, 2019, 74 (01) : 40 - 48
  • [46] Midterm Survival of Low-Risk Patients Treated With Transcatheter Versus Surgical Aortic Valve Replacement: Meta-Analysis of Reconstructed Time-to-Event Data
    Sa, Michel Pompeu
    Jacquemyn, Xander
    van den Eynde, Jef
    Serna-Gallegos, Derek
    Chu, Danny
    Clavel, Marie-Annick
    Pibarot, Philippe
    Sultan, Ibrahim
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2023, 12 (21):
  • [47] Mortality of surgical redo aortic valve replacement versus transcatheter aortic valve-in-valve implantation in patients with degenerated aortic bioprosthesis: a meta-analysis
    Sanchez Recalde, A.
    Pardo, A.
    Salido Tahoces, L.
    Mestre, J. L.
    Hernandez Antolin, R.
    Sanmartin, M.
    Zamorano, J. L.
    EUROPEAN HEART JOURNAL, 2019, 40 : 2438 - 2438
  • [48] A Meta-Analysis of Transcatheter Aortic Valve Implantation Versus Surgical Aortic Valve Replacement
    Takagi, Hisato
    Niwa, Masao
    Mizuno, Yusuke
    Goto, Shin-nosuke
    Umemoto, Takuya
    ANNALS OF THORACIC SURGERY, 2013, 96 (02): : 513 - 519
  • [49] Aortic valve replacement vs balloon-expandable and self-expandable transcatheter implantation: a network meta-analysis
    Bruno, Francesco
    D'Ascenzo, Fabrizio
    Baldetti, Luca
    Franchin, Luca
    Marengo, Giorgio
    Beviario, Susanna
    Melillo, Francesco
    Gallone, Guglielmo
    De Filippo, Ovidio
    La Torre, Michele
    Rinaldi, Mauro
    Omede, Pierluigi
    Conrotto, Federico
    Salizzoni, Stefano
    Giustetto, Carla
    De Ferrari, Gaetano Maria
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2020, 22 (0N) : N54 - N54
  • [50] AORTIC VALVE REPLACEMENT VS BALLOON-EXPANDABLE AND SELF-EXPANDABLE TRANSCATHETER IMPLANTATION: A NETWORK META-ANALYSIS
    Bruno, Francesco
    D'Ascenzo, Fabrizio
    Baldetti, Luca
    Franchin, Luca
    Marengo, Giorgio
    Breviario, Susanna
    Melillo, Francesco
    Gallone, Guglielmo
    De Filippo, Ovidio
    La Torre, Michele
    Rinaldi, Mauro
    Omede, Pierluigi
    Conrotto, Federico
    Salizzoni, Stefano
    De Ferrari, Gaetano
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2021, 77 (18) : 1157 - 1157