Late Survival After Valve-in-Valve Transcatheter Aortic Valve Implantation With Balloon- Versus Self- Expandable Valves: Meta-Analysis of Reconstructed Time-to-Event Data

被引:1
|
作者
Sa, Michel Pompeu [1 ,2 ]
Jacquemyn, Xander [3 ]
Simonato, Matheus [4 ]
Brown, James A. [1 ,2 ]
Ahmad, Danial [1 ,2 ]
Serna-Gallegos, Derek [1 ,2 ]
Clavel, Marie-Annick [5 ,6 ]
Pibarot, Philippe [5 ,6 ]
Dvir, Danny [7 ,8 ]
Sultan, Ibrahim [1 ,2 ]
机构
[1] Univ Pittsburgh, Dept Cardiothorac Surg, Pittsburgh, PA 15260 USA
[2] Univ Pittsburgh, UPMC Heart & Vasc Inst, Med Ctr, Pittsburgh, PA 15260 USA
[3] Katholieke Univ Leuven, Dept Cardiovasc Sci, Leuven, Belgium
[4] Yale Sch Med, New Haven, CT USA
[5] Ctr Rech Inst Univ Cardiol & Pneumol Quebec, Quebec City, PQ, Canada
[6] Univ Laval, Fac Med, Dept Med, Quebec City, PQ, Canada
[7] Hebrew Univ Jerusalem, Shaare Zedek Med Ctr, Dept Cardiol, Jerusalem, Israel
[8] Hebrew Univ Jerusalem, Fac Med, Jerusalem, Israel
来源
关键词
aortic valve; cardiac surgical procedures; cardiovascular surgical procedures; heart valve prosthesis implantation; meta-analysis; transcatheter aortic valve replacement; REPLACEMENT;
D O I
10.1016/j.amjcard.2023.09.108
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Valve-in-valve (ViV) transcatheter aortic valve implantation (TAVI) in patients with failed bioprostheses arose as an alternative to redo surgical aortic valve replacement. There is an increasing interest in exploring the differences between self-expanding valves (SEVs) and balloon-expandable valves (BEVs). Our study aimed to evaluate the all-cause mortality in ViV-TAVI with SEV versus BEV in patients with failed bioprostheses. We performed a study-level meta-analysis of reconstructed time-to-event data from Kaplan -Meier curves of studies published by March 30, 2023. A total of 5 studies met our eligibil-ity criteria and included 1,454 patients who underwent ViV-TAVI (862 with SEV and 592 with BEV). Almost all BEVs were iterations of the Edwards BEVs (SAPIEN, SAPIEN XT, and SAPIEN 3) and almost all SEVs were iterations of the Medtronic SEVs (CoreValve/ Evolut). During the first year after ViV-TAVI, 67 deaths (11.8%) occurred in patients treated with BEV compared with 92 deaths (11.1%) in patients treated with SEV (hazard ratio 0.92, 95% confidence interval 0.66 to 1.27, p = 0.632). At 8 years of follow-up, the all-cause death was not statistically significantly different between the groups, with mortality rates of 65.4% in the group treated BEV and 58.8% in the group treated with SEV (hazard ratio 0.91, 95% confidence interval 0.75 to 1.09, p = 0.302). The restricted mean survival time was overall 0.25 years greater with SEV than BEV, but this difference was not statistically significant (p = 0.278), which indicates no lifetime gain or loss with SEV in comparison with BEV. There seems to be no difference in terms of all-cause death in ViV-TAVI with SEV versus BEV. Randomized controlled trials are warranted to validate our results.(c) 2023 Elsevier Inc. All rights reserved. (Am J Cardiol 2023;209:120-127)
引用
收藏
页码:120 / 127
页数:8
相关论文
共 50 条
  • [21] Comparative Meta-Analysis of Balloon Expandable and Self-Expandable Valves for Transcatheter Aortic Valve Replacement
    Agarwal, Shikhar
    Parashar, Akhil
    Svensson, Lars G.
    Krishnaswamy, Amar
    Tuzcu, E. M.
    Kapadia, Samir R.
    CIRCULATION, 2014, 130
  • [22] Five-year outcomes in trials comparing transcatheter aortic valve implantation versus surgical aortic valve replacement: a pooled meta-analysis of reconstructed time-to-event data
    Barili, Fabio
    Freemantle, Nicholas
    Musumeci, Francesco
    Martin, Barbara
    Anselmi, Amedeo
    Rinaldi, Mauro
    Kaul, Sanjay
    Rodriguez-Roda, Jorge
    Di Mauro, Michele
    Folliguet, Thierry
    Verhoye, Jean-Philippe
    Sousa-Uva, Miguel
    Parolari, Alessandro
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2022, 61 (05) : 977 - 987
  • [23] Clinical and hemodynamic outcomes of self-expanding and balloon-expandable valves for valve-in-valve transcatheter aortic valve implantation (ViV-TAVI): An updated systematic review and meta-analysis
    Yasmin, Farah
    Moeed, Abdul
    Iqbal, Kinza
    Ali, Abraish
    Kumar, Ashish
    Basit, Jawad
    Hamza, Mohammad
    Dani, Sourbha S.
    Kalra, Ankur
    IJC HEART & VASCULATURE, 2025, 57
  • [24] Meta-Analysis of Valve-in-Valve Transcatheter Aortic Valve Implantation Versus Redo-surgical Aortic Valve Replacement in Failed Bioprosthetic Aortic Valve
    Al-abcha, Abdullah
    Saleh, Yehia
    Boumegouas, Manel
    Prasad, Rohan
    Herzallah, Khader
    Baloch, Zulfiqar Qutrio
    Abdelkarim, Ola
    Rayamajhi, Supratik
    Abela, George S.
    AMERICAN JOURNAL OF CARDIOLOGY, 2021, 146 : 74 - 81
  • [25] TRANSCATHETER AORTIC VALVE-IN-VALVE IMPLANTATION USING A BALLOON-EXPANDABLE VALVE IN PATIENTS WITH DEGENERATED STENTED VERSUS STENTLESS AORTIC BIOPROSTHESIS
    Moubarak, Ghadi
    El Shami, Mohamad
    Eisenga, John
    McCullough, Kyle
    Banwait, Jasjit K.
    Szerlip, Molly
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2024, 83 (13) : 996 - 996
  • [26] Pacemaker implantation after balloon- or self-expandable transcatheter aortic valve replacement in patients with aortic stenosis
    Bodin, A.
    Bisson, A.
    Herbert, J.
    Lacour, T.
    Saint Etienne, C.
    Pierre, B.
    Deharo, P.
    Babuty, D.
    Clementy, N.
    Fauchier, L.
    EUROPEAN HEART JOURNAL, 2020, 41 : 714 - 714
  • [27] Meta-analysis of Valve-in-Valve Transcatheter versus Redo Surgical Aortic Valve Replacement
    Takagi, Hisato
    Mitta, Shohei
    Ando, Tomo
    THORACIC AND CARDIOVASCULAR SURGEON, 2019, 67 (04): : 243 - 250
  • [28] Infective Endocarditis Following Transcatheter Aortic Valve Replacement Comparison of Balloon- Versus Self-Expandable Valves
    Regueiro, Ander
    Linke, Axel
    Latib, Azeem
    Ihlemann, Nikolaj
    Urena, Marina
    Walther, Thomas
    Husser, Oliver
    Herrmann, Howard C.
    Nombela-Franco, Luis
    Cheema, Asim
    Le Breton, Herve
    Stortecky, Stefan
    Kapadia, Samir
    Bartorelli, Antonio L.
    Sinning, Jan Malte
    Amat-Santos, Ignacio
    Munoz-Garcia, Antonio J.
    Lerakis, Stamatios
    Gutierrez-Ibanes, Enrique
    Abdel-Wahab, Mohamed
    Tchetche, Didier
    Testa, Luca
    Eltchaninoff, Helene
    Livi, Ugolino
    Castillo, Juan Carlos
    Jilaihawi, Hasan
    Webb, John G.
    Barbanti, Marco
    Kodali, Susheel
    de Brito Jr, Fabio S.
    Ribeiro, Henrique B.
    Miceli, Antonio
    Fiorina, Claudia
    Dato, Guglielmo Mario Actis
    Rosato, Francesco
    Serra, Vicenc
    Masson, Jean-Bernard
    Wijeysundera, Harindra C.
    Mangione, Jose A.
    Ferreira, Maria-Cristina
    Lima, Valter C.
    Carvalho, Luis A.
    Abizaid, Alexandre
    Marino, Marcos A.
    Esteves, Vinicius
    Andrea, Julio C. M.
    Messika-Zeitoun, David
    Himbert, Dominique
    Kim, Won-Keun
    Pellegrini, Costanza
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2019, 12 (11)
  • [29] Comparative meta-analysis of balloon-expandable and self-expandable valves for transcatheter aortic valve replacement
    Agarwal, Shikhar
    Parashar, Akhil
    Kumbhani, Dharam J.
    Svensson, Lars G.
    Krishnaswamy, Amar
    Tuzcu, E. Murat
    Kapadia, Samir R.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2015, 197 : 87 - 97
  • [30] Pacemaker Implantation After Balloon- or Self-Expandable Transcatheter Aortic Valve Replacement in Patients With Aortic Stenosis
    Bisson, Arnaud
    Bodin, Alexandre
    Herbert, Julien
    Lacour, Thibaut
    Saint Etienne, Christophe
    Pierre, Bertrand
    Clementy, Nicolas
    Deharo, Pierre
    Babuty, Dominique
    Fauchier, Laurent
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2020, 9 (09):