Assessing the efficacy of saline flush in frequency-domain optical coherence tomography for intracoronary imaging

被引:0
|
作者
Kimura, Masahiro [1 ]
Takeda, Teruki [1 ]
Tsujino, Yasushi [1 ]
Matsumoto, Yuichi [1 ]
Yamaji, Masayuki [1 ]
Sakaguchi, Tomoko [1 ]
Maeda, Keiko [1 ]
Mabuchi, Hiroshi [1 ]
Murakami, Tomoyuki [1 ]
机构
[1] Koto Mem Hosp, Dept Cardiovasc Med, 2-1 Hiramatsu Cho, Higashiomi, Shiga 5270134, Japan
关键词
Contrast; Heparinized saline; Intracoronary imaging; Optical coherence tomography; Percutaneous coronary intervention; PERCUTANEOUS CORONARY INTERVENTION; MOLECULAR-WEIGHT DEXTRAN; CLINICAL-APPLICATIONS; CONTRAST-MEDIA; TERMINOLOGY; ACQUISITION; METHODOLOGY; DOCUMENT;
D O I
10.1007/s00380-023-02340-y
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundThe increased amount of contrast media in frequency-domain optical coherence tomography (FD-OCT) imaging during percutaneous coronary intervention (PCI) has raised potential concerns regarding impairment of renal function.ObjectivesThis study aimed to evaluate the effectiveness of heparinized saline flush in FD-OCT-guided PCI and identify clinical factors contributing to optimal image quality.MethodsWe retrospectively collected 100 lesions from 90 consecutive patients, and a total of 200 pullbacks were analyzed for the initial and final evaluation in which saline was used as the flushing medium.ResultsThe study population had a mean age of 73, with 52% having chronic kidney disease (CKD). The median amount of contrast used was 28 ml, and no complications were observed associated with saline flush OCT. Imaging quality was then categorized as excellent, good, or unacceptable. Among the total runs, 87% demonstrated clinically acceptable image quality, with 66.5% classified as excellent images and 20.5% classified as good images. Independent predictors of excellent images included lumen area stenosis >= 70% (adjusted odds ratio [OR] 2.37, 95% confidence interval [CI] 1.02-5.47, P = 0.044), and the use of intensive flushing (adjusted OR 2.06, 95% CI 1.11-3.86, P = 0.023) defined as a deep engagement of guiding catheter (GC) or a selective insertion of guide extension catheter (GE). Intensive flushing was performed in 60% of the total pullbacks, and it was particularly effective in improving image quality in the left coronary artery (LCA).ConclusionThe use of saline flush during FD-OCT imaging was safe and feasible, which had a benefit in renal protection with adequate imaging quality.
引用
收藏
页码:310 / 318
页数:9
相关论文
共 50 条
  • [41] Frequency-domain Optical Coherence Tomography Findings of Population With High Skin Auto Fluorescence
    Fujino, Yusuke
    Tahara, Satoko
    Naganum, Toru
    Yabushita, Hiroto
    Wang, Wei
    Nakamura, Sunao
    [J]. CIRCULATION, 2015, 132
  • [42] Fienup Algorithm With Sparsity Constraints: Application to Frequency-Domain Optical-Coherence Tomography
    Mukherjee, Subhadip
    Seelamantula, Chandra Sekhar
    [J]. IEEE TRANSACTIONS ON SIGNAL PROCESSING, 2014, 62 (18) : 4659 - 4672
  • [43] Intracoronary Optical Coherence Tomography
    Nicholls, Stephen J.
    Puri, Rishi
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 62 (19) : 1759 - 1760
  • [44] DESolve novolimus-eluting bioresorbable coronary scaffold failure assessed by frequency-domain optical coherence tomography imaging
    Porto, Italo
    Vergallo, Rocco
    Sangiorgi, Giuseppe M.
    Burzotta, Francesco
    Garbo, Roberto
    D'Amario, Domenico
    Trani, Carlo
    Rebuzzi, Antonio G.
    Crea, Filippo
    [J]. CORONARY ARTERY DISEASE, 2016, 27 (04) : 334 - 336
  • [45] Imaging assessment and accuracy in coronary artery autopsy: comparison of frequency-domain optical coherence tomography with intravascular ultrasound and histology
    Shimokado, Aiko
    Kubo, Takashi
    Matsu, Yoshiki
    Ino, Yasushi
    Shiono, Yasutsugu
    Shimamura, Kunihiro
    Katayama, Yosuke
    Taruya, Akira
    Nishiguchi, Tsuyoshi
    Kashiwagi, Manabu
    Kitabata, Hironori
    Tanaka, Atsushi
    Hozumi, Takeshi
    Akasaka, Takashi
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2019, 35 (10): : 1785 - 1790
  • [46] Imaging assessment and accuracy in coronary artery autopsy: comparison of frequency-domain optical coherence tomography with intravascular ultrasound and histology
    Aiko Shimokado
    Takashi Kubo
    Yoshiki Matsuo
    Yasushi Ino
    Yasutsugu Shiono
    Kunihiro Shimamura
    Yosuke Katayama
    Akira Taruya
    Tsuyoshi Nishiguchi
    Manabu Kashiwagi
    Hironori Kitabata
    Atsushi Tanaka
    Takeshi Hozumi
    Takashi Akasaka
    [J]. The International Journal of Cardiovascular Imaging, 2019, 35 : 1785 - 1790
  • [47] Imaging atherosclerotic plaque composition with intracoronary optical coherence tomography
    van Soest, G.
    Goderie, T. P. M.
    Gonzalo, N.
    Koljenovic, S.
    van Leenders, G. L. J. H.
    Regar, E.
    Serruys, P. W.
    van der Steen, A. F. W.
    [J]. NETHERLANDS HEART JOURNAL, 2009, 17 (11): : 448 - 450
  • [48] Current and future developments in intracoronary optical coherence tomography imaging
    Barlis, Peter
    Schmitt, Joseph M.
    [J]. EUROINTERVENTION, 2009, 4 (04) : 529 - 533
  • [49] Imaging atherosclerotic plaque composition with intracoronary optical coherence tomography
    G. van Soest
    T. P. M. Goderie
    N. Gonzalo
    S. Koljenović
    G. L. J. H. van Leenders
    E. Regar
    P. W. Serruys
    A. F. W. van der Steen
    [J]. Netherlands Heart Journal, 2009, 17 : 448 - 450
  • [50] Experience with a novel high frequency optical coherence tomography device for intracoronary imaging: a case series
    Garin, Dorian
    Cook, Stephane
    Togni, Mario
    Meier, Pascal
    Wenaweser, Peter
    Puricel, Serban
    Arroyo, Diego
    [J]. FRONTIERS IN CARDIOVASCULAR MEDICINE, 2024, 11