Comparison of high-pressure and low-pressure fouling detectors at a full-scale seawater reverse osmosis desalination plant

被引:0
|
作者
Wu, Jishan [1 ,2 ]
Tanuwidjaja, Dian [1 ,2 ,3 ]
Guillen, Gregory R. [1 ,2 ]
Marambio-Jones, Catalina [1 ,2 ]
Cheng, Robert [3 ]
Edalat, Arian [4 ]
Hoek, Eric M. V. [1 ,2 ]
机构
[1] Univ Calif Los Angeles, Calif Nanosyst Inst, Dept Civil & Environm Engn, Los Angeles, CA 90095 USA
[2] Univ Calif Los Angeles, Inst Environm & Sustainabil, Los Angeles, CA 90095 USA
[3] Long Beach Water Dept, Long Beach, CA 90806 USA
[4] Pacifica Water Solut, Northridge, CA 91326 USA
关键词
Reverse osmosis; Nanofiltration; Biofouling; Seawater; Desalination; Fouling detector; OPTICAL COHERENCE TOMOGRAPHY; CROSS-FLOW; CONCENTRATION POLARIZATION; MEMBRANE-SURFACE; NANOFILTRATION; DEPOSITION; CANARY;
D O I
10.5004/dwt.2023.29640
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
In an attempt to better understand and control seawater reverse osmosis (RO) membrane fouling, low-pressure (LPFD) and high-pressure fouling detectors (HPFD) were employed in an ex situ, side stream configuration at a full-scale seawater desalination plant. These fouling detectors contained flat-sheet membrane and spacer materials extracted from the membrane modules installed at the plant. The high-pressure fouling detectors reasonably replicated full-scale plant permeate quality, permeate flux, and differential pressure, whereas low-pressure fouling detectors could only simulate differential pressure. When evaluating different pre-treatments, it was observed that activated carbon and chlorine dioxide (after chlorination, microfiltration and dechlorination) to be effective at preventing RO membrane fouling, whereas chlorination, microfiltration and dechlorination and the same sequence followed by ultraviolet irradiation were less effective. Accelerated fouling was found when dosing both colloidal and dissolved nutrients, but the colloidal nutrient caused more severe fouling through a combination of colloidal cake layer formation in addition to biofilm formation and growth. In some cases, differential pressure may be an adequate early warning fouling indicator, but in this study, the high-pressure fouling detector more accurately captured plant fouling impacts. Finally, full-scale seawater RO plant fouling impacts were sufficiently captured while monitoring only pressure, flow and electrical conductivity; therefore, the added cost and complexity of employing more sophisticated optical, electrical, ultrasonic or other methods in ex situ, side stream fouling detectors may not be justified.
引用
收藏
页码:1 / 16
页数:16
相关论文
共 50 条
  • [41] Life cycle cost of a hybrid forward osmosis low pressure reverse osmosis system for seawater desalination and wastewater recovery
    Linares, R. Valladares
    Li, Z.
    Yangali-Quintanilla, V.
    Ghaffour, N.
    Amy, G.
    Leiknes, T.
    Vrouwenvelder, J. S.
    WATER RESEARCH, 2016, 88 : 225 - 234
  • [42] Fluorescence characterization of organic matter and fouling: Case study in a full-scale reverse osmosis membrane treatment plant
    Bergman, Lauren E.
    Jones, Kimberly L.
    VanBriesen, Jeanne M.
    WATER ENVIRONMENT RESEARCH, 2020, 92 (02) : 161 - 172
  • [43] HIGH-PRESSURE OR LOW-PRESSURE AIR GUNS
    ZIOLKOWSKI, A
    GEOPHYSICS, 1981, 46 (04) : 447 - 448
  • [44] LOW-PRESSURE AND HIGH-PRESSURE PYROLYSIS[1]
    EGSGAARD, H
    CARLSEN, L
    THERMOCHIMICA ACTA, 1988, 134 : 321 - 326
  • [45] LOW-PRESSURE WELLHEAD FOR HIGH-PRESSURE STIMULATION
    GARVIN, T
    JOURNAL OF PETROLEUM TECHNOLOGY, 1994, 46 (05): : 383 - 383
  • [46] Fouling behavior of marine organic matter in reverse osmosis membranes of a real-scale seawater desalination plant in South Korea
    Lee, Yong-Gu
    Kim, Sangwon
    Shin, Jaegwan
    Rho, Hojung
    Lee, Younggeun
    Kim, Young Mi
    Park, Yongeun
    Oh, Sang-Eun
    Cho, Jaeweon
    Chon, Kangmin
    DESALINATION, 2020, 485
  • [47] Modeling boron rejection in pilot- and full-scale reverse osmosis desalination processes
    Mane, Pranay P.
    Park, Pyung-Kyu
    Hyung, Hoon
    Brown, Jess C.
    Kim, Jae-Hong
    JOURNAL OF MEMBRANE SCIENCE, 2009, 338 (1-2) : 119 - 127
  • [48] NUMERICAL AND EXPERIMENTAL INVESTIGATION OF PERFORMANCE AND RELIABILITY IN NEW REVERSE OSMOSIS SEAWATER DESALINATION HIGH PRESSURE PUMP
    Ye, Xiao-yan
    Hu, Jing-ning
    Wang, Jing
    Feng, Yao-ning
    Jiang, Wei
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2013, VOL 7B, 2014,
  • [49] Fouling in a high pressure, high recovery rotating reverse osmosis system
    Pederson, Cynthia L.
    Lueptow, Richard M.
    DESALINATION, 2007, 212 (1-3) : 1 - 14
  • [50] Addressing Reverse Osmosis Fouling within Water Reclamation-A Side-By-Side Comparison of Low-Pressure Membrane Pretreatments
    Kent, Fraser C.
    Farahbakhsh, Khosrow
    WATER ENVIRONMENT RESEARCH, 2011, 83 (06) : 515 - 526