Comparison of high-pressure and low-pressure fouling detectors at a full-scale seawater reverse osmosis desalination plant

被引:0
|
作者
Wu, Jishan [1 ,2 ]
Tanuwidjaja, Dian [1 ,2 ,3 ]
Guillen, Gregory R. [1 ,2 ]
Marambio-Jones, Catalina [1 ,2 ]
Cheng, Robert [3 ]
Edalat, Arian [4 ]
Hoek, Eric M. V. [1 ,2 ]
机构
[1] Univ Calif Los Angeles, Calif Nanosyst Inst, Dept Civil & Environm Engn, Los Angeles, CA 90095 USA
[2] Univ Calif Los Angeles, Inst Environm & Sustainabil, Los Angeles, CA 90095 USA
[3] Long Beach Water Dept, Long Beach, CA 90806 USA
[4] Pacifica Water Solut, Northridge, CA 91326 USA
关键词
Reverse osmosis; Nanofiltration; Biofouling; Seawater; Desalination; Fouling detector; OPTICAL COHERENCE TOMOGRAPHY; CROSS-FLOW; CONCENTRATION POLARIZATION; MEMBRANE-SURFACE; NANOFILTRATION; DEPOSITION; CANARY;
D O I
10.5004/dwt.2023.29640
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
In an attempt to better understand and control seawater reverse osmosis (RO) membrane fouling, low-pressure (LPFD) and high-pressure fouling detectors (HPFD) were employed in an ex situ, side stream configuration at a full-scale seawater desalination plant. These fouling detectors contained flat-sheet membrane and spacer materials extracted from the membrane modules installed at the plant. The high-pressure fouling detectors reasonably replicated full-scale plant permeate quality, permeate flux, and differential pressure, whereas low-pressure fouling detectors could only simulate differential pressure. When evaluating different pre-treatments, it was observed that activated carbon and chlorine dioxide (after chlorination, microfiltration and dechlorination) to be effective at preventing RO membrane fouling, whereas chlorination, microfiltration and dechlorination and the same sequence followed by ultraviolet irradiation were less effective. Accelerated fouling was found when dosing both colloidal and dissolved nutrients, but the colloidal nutrient caused more severe fouling through a combination of colloidal cake layer formation in addition to biofilm formation and growth. In some cases, differential pressure may be an adequate early warning fouling indicator, but in this study, the high-pressure fouling detector more accurately captured plant fouling impacts. Finally, full-scale seawater RO plant fouling impacts were sufficiently captured while monitoring only pressure, flow and electrical conductivity; therefore, the added cost and complexity of employing more sophisticated optical, electrical, ultrasonic or other methods in ex situ, side stream fouling detectors may not be justified.
引用
下载
收藏
页码:1 / 16
页数:16
相关论文
共 50 条
  • [21] Seawater reverse osmosis membrane fouling causes in a full scale desalination plant; through the analysis of environmental issues: raw water quality
    Rezaei, Leila
    Dehghani, Mohsen
    Hassani, Amir Hesam
    Alipour, Vali
    ENVIRONMENTAL HEALTH ENGINEERING AND MANAGEMENT JOURNAL, 2020, 7 (02): : 119 - 126
  • [22] Pilot scale fabrication of low fouling seawater desalination thin film composite reverse osmosis membrane
    Bera, Parthapratim
    Dhivagaran, D.
    Saha, Nirmal Kumar
    Jewrajka, Suresh K.
    DESALINATION, 2024, 586
  • [23] Simulation and Optimization of Full Scale Reverse Osmosis Desalination Plant
    Sassi, Kamal M.
    Mujtaba, Iqbal M.
    20TH EUROPEAN SYMPOSIUM ON COMPUTER AIDED PROCESS ENGINEERING, 2010, 28 : 895 - 900
  • [24] Cost of fouling in full-scale reverse osmosis and nanofiltration installations in the Netherlands
    Jafari, M.
    Vanoppen, M.
    van Agtmaal, J. M. C.
    Cornelissen, E. R.
    Vrouwenvelder, J. S.
    Verliefde, A.
    van Loosdrecht, M. C. M.
    Picioreanu, C.
    DESALINATION, 2021, 500
  • [25] A comprehensive evaluation of the temporal and spatial fouling characteristics of RO membranes in a full-scale seawater desalination plant
    Chen, Chao
    Yang, Yu
    Graham, Nigel J. D.
    Li, Zhenyu
    Yang, Xingtao
    Wang, Zhining
    Farhat, Nadia
    Vrouwenvelder, Johannes S.
    Hou, Li -an
    WATER RESEARCH, 2024, 249
  • [26] LOW-PRESSURE REVERSE-OSMOSIS DESALINATION WITH IMPROVED CELLULOSE-ACETATE MEMBRANES
    GHOSH, AK
    SIRKAR, KK
    JOURNAL OF APPLIED POLYMER SCIENCE, 1979, 23 (05) : 1291 - 1307
  • [27] Practical limit of energy production from seawater by full-scale pressure retarded osmosis
    Kim, Minseok
    Kim, Suhan
    ENERGY, 2018, 158 : 373 - 382
  • [28] Forward osmosis and pressure retarded osmosis process modeling for integration with seawater reverse osmosis desalination
    Binger, Zachary M.
    Achilli, Andrea
    DESALINATION, 2020, 491
  • [29] Fouling of reverse osmosis membrane for municipal wastewater reclamation: Autopsy results from a full-scale plant
    Tang, Fang
    Hu, Hong-Ying
    Sun, Li-Juan
    Wu, Qian-Yuan
    Jiang, Yan-Mei
    Guan, Yun-Tao
    Huang, Jing-Jing
    DESALINATION, 2014, 349 : 73 - 79
  • [30] Fouling characteristics of reverse osmosis membranes at different positions of a full-scale plant for municipal wastewater reclamation
    Tang, Fang
    Hu, Hong-Ying
    Sun, Li-Juan
    Sun, Ying-Xue
    Shi, Na
    Crittenden, John C.
    WATER RESEARCH, 2016, 90 : 329 - 336