A new predictive parameter for dose-volume metrics in intensity-modulated radiation therapy planning for prostate cancer: Initial phantom study

被引:0
|
作者
Saito, Yuki [1 ]
Suzuki, Ryusuke [1 ,2 ,7 ]
Miyamoto, Naoki [2 ,3 ]
Sutherland, Kenneth Lee [4 ]
Kanehira, Takahiro [1 ,2 ]
Tamura, Masaya [1 ,2 ]
Mori, Takashi [5 ]
Nishioka, Kentaro [4 ,5 ]
Hashimoto, Takayuki [4 ,5 ]
Aoyama, Hidefumi [5 ,6 ]
机构
[1] Hokkaido Univ, Grad Sch Biomed Sci & Engn, Sapporo, Japan
[2] Hokkaido Univ Hosp, Dept Med Phys, Sapporo, Japan
[3] Hokkaido Univ, Fac Engn, Sapporo, Japan
[4] Hokkaido Univ, Fac Med, Global Ctr Biomed Sci & Engn, Sapporo, Japan
[5] Hokkaido Univ Hosp, Dept Radiat Oncol, Sapporo, Japan
[6] Hokkaido Univ, Fac Med, Dept Radiat Oncol, Sapporo, Japan
[7] Hokkaido Univ Hosp, Dept Med Phys, North-14 West-5,Kita Ku, Sapporo, Japan
来源
关键词
intensity-modulated radiation therapy; overlap volume; pinnacle(3) Auto-Planning; plan quality; prostate cancer; step and shoot; volumetric modulated arc therapy; CONFORMAL RADIOTHERAPY; ARC THERAPY; CONSTRAINTS; MORBIDITY; TOXICITY; MODEL; PLANS; HEAD;
D O I
10.1002/acm2.14250
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Organ-at-risk (OAR) sparing is often assessed using an overlap volume-based parameter, defined as the ratio of the volume of OAR that overlaps the planning target volume (PTV) to the whole OAR volume. However, this conventional overlap-based predictive parameter (COPP) does not consider the volume relationship between the PTV and OAR.Purpose: We propose a new overlap-based predictive parameter that consider the PTV volume. The effectiveness of proposed overlap-based predictive parameter (POPP) is evaluated compared with COPP.Methods: We defined as POPP = (overlap volume between OAR and PTV/OAR volume) x (PTV volume/OAR volume). We generated intensity modulated radiation therapy (IMRT) based on step and shoot technique, and volumetric modulated arc therapy (VMAT) plans with the Auto-Planning module of Pinnacle(3) treatment planning system (v14.0, Philips Medical Systems, Fitchburg, WI) using the American Association of Physicists in Medicine Task Group (TG119) prostate phantom. The relationship between the position and size of the prostate phantom was systematically modified to simulate various geometric arrangements. The correlation between overlap-based predictive parameters (COPP and POPP) and dose-volume metrics (mean dose, V-70Gy, V-60Gy, and V-37.5 Gy for rectum and bladder) was investigated using linear regression analysis.Results: Our results indicated POPP was better than COPP in predicting intermediate-dose metrics. The bladder results showed a trend similar to that of the rectum. The correlation coefficient of POPP was significantly greater than that of COPP in < 62 Gy (82% of the prescribed dose) region for IMRT and in < 55 Gy (73% of the prescribed dose) region for VMAT regarding the rectum (p < 0.05).Conclusions: POPP is superior to COPP for creating predictive models at an intermediate-dose level. Because rectal bleeding and bladder toxicity can be associated with intermediate-doses as well as high-doses, it is important to predict dose-volume metrics for various dose levels. POPP is a useful parameter for predicting dose-volume metrics and assisting the generation of treatment plans.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] LATE TOXICITY AFTER INTENSITY-MODULATED RADIATION THERAPY FOR LOCALIZED PROSTATE CANCER: AN EXPLORATION OF DOSE-VOLUME HISTOGRAM PARAMETERS TO LIMIT GENITOURINARY AND GASTROINTESTINAL TOXICITY
    Pederson, Aaron W.
    Fricano, Janine
    Correa, David
    Pelizzari, Charles A.
    Liauw, Stanley L.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 82 (01): : 235 - 241
  • [22] Bladder dose-volume parameters are associated with urinary incontinence after postoperative intensity modulated radiation therapy for prostate cancer
    Son, Christina H.
    Melotek, James M.
    Liao, Chuanhong
    Hubert, Greg
    Pelizzari, Charles A.
    Eggener, Scott E.
    Liauw, Stanley L.
    [J]. PRACTICAL RADIATION ONCOLOGY, 2016, 6 (05) : E179 - E185
  • [23] Sparsity constrained split feasibility for dose-volume constraints in inverse planning of intensity-modulated photon or proton therapy
    Penfold, Scott
    Zalas, Rafal
    Casiraghi, Margherita
    Brooke, Mark
    Censor, Yair
    Schulte, Reinhard
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (09): : 3599 - 3618
  • [24] Treatment planning comparison between high dose rate and intensity-modulated radiation therapy for prostate cancer as a means of boost dose
    Bose, Satya
    Bahri, Sanjeev
    Lalonde, Ron
    [J]. JOURNAL OF RADIOTHERAPY IN PRACTICE, 2014, 13 (03) : 332 - 339
  • [25] Urologists' Use of Intensity-Modulated Radiation Therapy for Prostate Cancer
    Mitchell, Jean M.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2013, 369 (17): : 1629 - 1637
  • [26] Intensity-modulated radiation therapy: Supportive data for prostate cancer
    Cahlon, Oren
    Hunt, Margie
    Zelefsky, Michael J.
    [J]. SEMINARS IN RADIATION ONCOLOGY, 2008, 18 (01) : 48 - 57
  • [27] Reimbursement and use of intensity-modulated radiation therapy for prostate cancer
    Shahinian, Vahakn B.
    Kaufman, Samuel R.
    Yan, Phyllis
    Herrel, Lindsey A.
    Borza, Tudor
    Hollenbeck, Brent K.
    [J]. MEDICINE, 2017, 96 (25)
  • [28] Concave Approximations of Target Volume Dose Metrics for Intensity-Modulated Radiotherapy Treatment Planning
    Xie, Y.
    Chen, Y.
    Wickerhauser, M.
    Deasy, J.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 312 - 312
  • [29] Direct optimization of dose-volume histogram metrics in radiation therapy treatment planning
    Zhang, Tianfang
    Bokrantz, Rasmus
    Olsson, Jimmy
    [J]. BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2020, 6 (06)
  • [30] Dose-Volume Comparison of Intensity-Modulated Radiation Therapy and Passive Scattering Proton Therapy Treatment Plans for Early-Stage Glottic Cancer
    Kato, T.
    Fuwa, N.
    Murakami, M.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E749 - E749