Parameter optimization in a finite element mandibular fracture fixation model using the design of experiments approach

被引:2
|
作者
Maintz, Michaela [1 ,2 ,3 ,7 ]
Msallem, Bilal [1 ,2 ]
de Wild, Michael [3 ]
Seiler, Daniel [3 ]
Herrmann, Sven [4 ]
Feiler, Stefanie [5 ]
Sharma, Neha [1 ,2 ]
Dalcanale, Federico [3 ]
Cattin, Philippe [6 ]
Thieringer, Florian Markus [1 ,2 ]
机构
[1] Univ Basel, Dept Biomed Engn, Med Addit Mfg Res Grp Swiss MAM, Allschwil, Switzerland
[2] University Hosp Basel, Dept Oral & Cranio Maxillofacial Surg, Basel, Switzerland
[3] Univ Appl Sci & Arts Northwestern Switzerland FHNW, Inst Med Engn & Med Informat IM2, Muttenz, Switzerland
[4] Simq GmbH, Grafing, Germany
[5] Univ Appl Sci & Arts Northwestern Switzerland FHNW, Initial & Continuing Educ, Grp Appl Math Life Sci, AICOS Technol Ltd, Allschwil, Switzerland
[6] Univ Basel, Ctr Med Image Anal & Nav CIAN, Dept Biomed Engn, Basel, Switzerland
[7] Univ Basel, Dept Biomed Engn, Med Addit Mfg Res Grp Swiss MAM, CH-4123 Allschwil, Switzerland
关键词
Mandible; Three dimensional printing; Validation; Cranio-maxillofacial; Simulation; Implant; RECONSTRUCTION PLATES; OSTEOSYNTHESIS; RESECTION; LOCKING; SYSTEMS;
D O I
10.1016/j.jmbbm.2023.105948
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Only a few mandibular bone finite element (FE) models have been validated in literature, making it difficult to assess the credibility of the models. In a comparative study between FE models and biomechanical experiments using a synthetic polyamide 12 (PA12) mandible model, we investigate how material properties and boundary conditions affect the FE model's accuracy using the design of experiments approach. Multiple FE parameters, such as contact definitions and the materials' elastic and plastic deformation characteristics, were systematically analyzed for an intact mandibular model and transferred to the fracture fixation model. In a second step, the contact definitions for the titanium screw and implant (S-I), implant and PA12 mandible (I-M), and interfragmentary (IF) PA12 segments were optimized. Comparing simulated deformations (from 0 to 5 mm) and reaction forces (from 10 to 1' 415 N) with experimental results showed a strong sensitivity to FE mechanical properties and contact definitions. The results suggest that using the bonded definition for the screw-implant contact of the fracture plate is ineffective. The contact friction parameter set with the highest agreement was identified: titanium screw and implant mu = 0.2, implant and PA12 mandible mu = 0.2, interfragmentary PA12 mandible mu = 0.1. The simulated reaction force (RMSE = 26.60 N) and surface displacement data (RMSE = 0.19 mm) of the FE analysis showed a strong agreement with the experimental biomechanical data. The results were generated through parameter optimization which means that our findings need to be validated in the event of a new dataset with deviating anatomy. Conclusively, the predictive capability of the FE model can be improved by FE model calibration through experimental testing. Validated preoperative quasi-static FE analysis could allow engineers and surgeons to accurately estimate how the implant's choice and placement suit the patient's biomechanical needs.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] FINITE-ELEMENT ANALYSIS OF A FRACTURE FIXATION SYSTEM
    HULSE, D
    AUER, J
    NELSON, J
    VETERINARY SURGERY, 1987, 16 (01) : 93 - 93
  • [32] Optimization of the crankshaft using finite element analysis approach
    V. C. Shahane
    R. S. Pawar
    Automotive and Engine Technology, 2017, 2 (1-4) : 1 - 23
  • [33] Optimization of Tibial Stem Geometry in Total Knee Arthroplasty Using Design of Experiments: A Finite Element Analysis
    Lee, Hyun Hee
    Hong, Hyoung-Taek
    Kim, Jong-Keun
    Koh, Yong-Gon
    Park, Kwan Kyu
    Kang, Kyoung-Tak
    BIOENGINEERING-BASEL, 2025, 12 (02):
  • [34] MODELING AND OPTIMIZATION OF AN ELLIPTICAL SHAPE ULTRASONIC MOTOR USING COMBINATION OF FINITE ELEMENT METHOD AND DESIGN OF EXPERIMENTS
    Sanikhani, Hamed
    Akbari, Javad
    Shahidi, Ali Reza
    Darki, Ali Akbar
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION - 2010, VOL 8, PTS A AND B, 2012, : 491 - 496
  • [35] Evaluation of forearm fixation plate design using finite element methods
    Saidpour, SH
    Flitta, IM
    Velay, X
    SIMULATION MODELLING IN BIOENGINEERING, 1996, : 119 - 126
  • [36] Stability of finite element models for distributed-parameter optimization and topology design
    Jog, CS
    Haber, RB
    COMPUTER METHODS IN APPLIED MECHANICS AND ENGINEERING, 1996, 130 (3-4) : 203 - 226
  • [37] Comparative Evaluation of 7 Fixation Plates in Mandibular Angle Fractures Using Finite Element Analysis
    Naeini, Ehsan
    Sarkarat, Farzin
    Jamilian, Adbolreza
    Motamedi, Mohammad Hosein Kalantar
    TRAUMA MONTHLY, 2020, 25 (04) : 145 - 152
  • [38] FINITE-ELEMENT ANALYSIS OF A MANDIBULAR MODEL
    FARAH, JW
    CRAIG, RG
    MEROUEH, KA
    JOURNAL OF ORAL REHABILITATION, 1988, 15 (06) : 615 - 624
  • [39] MODEL ALIGNMENT USING OPTIMIZATION AND DESIGN OF EXPERIMENTS
    Teran-Somohano, Alejandro
    Smith, Alice E.
    Yilmaz, Levent
    2017 WINTER SIMULATION CONFERENCE (WSC), 2017, : 1288 - 1299
  • [40] A novel approach for stochastic finite element model updating and parameter estimation
    Ma, Tianzheng
    Zhang, Yimin
    Huang, Xianzhen
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2014, 228 (18) : 3329 - 3342