Post-tensioning tendon force estimation using eddy currents at various temperature conditions

被引:0
|
作者
Lim, Hyung Jin [1 ]
Kwon, Ohjun [2 ]
Sohn, Hoon [2 ]
机构
[1] Kyonggi Univ, Dept Civil & Energy Syst Engn, Suwon 16227, South Korea
[2] Korea Adv Inst Sci & Technol, Dept Civil & Environm Engn, Daejeon 34141, South Korea
基金
新加坡国家研究基金会;
关键词
Non -destructive testing; Post-tensioning tendon; Eddy current measurement; Piezoresistivity; Temperature effect; TENSION FORCE; PRESTRESS; SENSORS; STRANDS;
D O I
10.1016/j.ndteint.2023.103031
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
This study proposes an eddy current-based tensile force estimation technique for a post-tensioning (PT) tendon under varying temperature conditions. The tensile force in the internal PT tendon is inferred by measuring the compressive stress on the external anchor head. A dual-coil probe consisting of two identical eddy current coils with orthogonal orientations measures the unidirectional loading level based on the piezoresistive effect. The temperature effect is eliminated using identical eddy current signal alternations in the coils under temperature variation. The performance of the proposed technique was evaluated by estimating the tensile force of a PT tendon under various loading and temperature conditions. The uniqueness of this study lies in the (1) design and fabrication of a dual-coil probe for unidirectional loading level estimation, (2) elimination of the effect of temperature on tensile force estimation, and (3) experimental validation under various loading and temperature conditions.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Post-tensioning Tendon Force Loss Detection Using Low Power Pulsed Eddy Current Measurement
    Kim, Ji-Min
    Lee, Jun
    Sohn, Hoon
    [J]. 44TH ANNUAL REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOL 37, 2018, 1949
  • [2] Detection of tension force reduction in a post-tensioning tendon using pulsed-eddy-current measurement
    Kim, Ji-Min
    Lee, Jun
    Sohn, Hoon
    [J]. STRUCTURAL ENGINEERING AND MECHANICS, 2018, 65 (02) : 129 - 139
  • [3] Post-tensioning tendon force estimation of in-service prestressed concrete structure using cylindrical lamb waves
    Kwon, Ohjun
    Sohn, Hoon
    Lim, Hyung Jin
    [J]. STRUCTURAL HEALTH MONITORING-AN INTERNATIONAL JOURNAL, 2024,
  • [4] SELECTING POST-TENSIONING TENDON PROTECTION LEVELS
    Krauser, Larry B.
    [J]. FIB SYMPOSIUM PRAGUE 2011: CONCRETE ENGINEERING FOR EXCELLENCE AND EFFICIENCY, VOLS 1 AND 2, 2011, : 679 - 682
  • [5] Monitoring of Grouting Compactness in a Post-Tensioning Tendon Duct Using Piezoceramic Transducers
    Jiang, Tianyong
    Kong, Qingzhao
    Wang, Wenxi
    Huo, Linsheng
    Song, Gangbing
    [J]. SENSORS, 2016, 16 (08)
  • [6] UNBONDED SINGLE STRAND POST-TENSIONING TENDON DETAILS.
    Schupack, Morris
    [J]. Concrete Construction - World of Concrete, 1988, 33 (07): : 668 - 670
  • [7] Monitoring of Grouting Compactness in a Post-Tensioning Curve Tendon Duct Using Piezoceramic Transducers
    Jiang, Tianyong
    Jiang, Bin
    Zhang, Yaowen
    Tian, Zhongchu
    Song, Gangbing
    [J]. EARTH AND SPACE 2021: MATERIALS, STRUCTURES, DYNAMICS, AND CONTROL IN EXTREME ENVIRONMENTS, 2021, : 307 - 320
  • [8] Repair and retrofitting using external post-tensioning
    [J]. Concrete Construction, 1991, 36 (07):
  • [9] High Tensile Bond Anchorage for Post-tensioning Bar Tendon Systems
    Loeffler, Kay
    Birckel, Thomas
    [J]. HIGH TECH CONCRETE: WHERE TECHNOLOGY AND ENGINEERING MEET, 2018, : 2451 - 2457
  • [10] Laboratory measurements of masonry using post-tensioning
    Stara, Marie
    [J]. CIVIL, STRUCTURAL AND ENVIRONMENTAL ENGINEERING, PTS 1-4, 2014, 838-841 : 2000 - 2003