Laboratory measurements of masonry using post-tensioning

被引:1
|
作者
Stara, Marie [1 ]
机构
[1] VSB TU Ostrava, Fac Civil Engn, Ostrava 70833, Czech Republic
关键词
Masonry; Measurement; Pre-stressing; Deformation;
D O I
10.4028/www.scientific.net/AMR.838-841.2000
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Contribution deals with laboratory measurements of deformations in the place exposed to local load caused by additional pre-stressing. The measurements are made at the masonry corner built in the laboratory equipment. The laboratory equipment was designed at Faculty of Civil Engineering VSB TU Ostrava for measurement tri-axial stress-strain conditions in masonry. In this masonry corner two pre-stressing bars are placed. These bars are in different height and are anchored to the anchor plates, which transfer pre-stressing forces to the masonry. The masonry was pre-stressed in the both directions. The specimen for laboratory testing is performed in the proportion to the reality of 1:1.
引用
收藏
页码:2000 / 2003
页数:4
相关论文
共 50 条
  • [1] Enhancing the Structural Performance of Masonry Structures by Post-Tensioning
    Leonardo Todisco
    Elizabeth Stocks
    Javier León
    Hugo Corres
    [J]. Nexus Network Journal, 2018, 20 : 671 - 691
  • [2] Enhancing the Structural Performance of Masonry Structures by Post-Tensioning
    Todisco, Leonardo
    Stocks, Elizabeth
    Leon, Javier
    Corres, Hugo
    [J]. NEXUS NETWORK JOURNAL, 2018, 20 (03) : 671 - 691
  • [3] POST-TENSIONING
    HANUSCHAK, W
    [J]. CIVIL ENGINEERING, 1983, 53 (03): : 30 - 30
  • [4] Performance improvement studies of masonry houses using elastic post-tensioning straps
    Turer, Ahmet
    Korkmaz, Serra Zerrin
    Korkmaz, Hasan Husnu
    [J]. EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2007, 36 (05): : 683 - 705
  • [5] The application of external post-tensioning system to a damage masonry arch
    Zampieri, Paolo
    Piazzon, Riccardo
    Ferroni, Riccardo
    Pellegrino, Carlo
    [J]. XIX ANIDIS CONFERENCE, SEISMIC ENGINEERING IN ITALY, 2023, 44 : 605 - 609
  • [6] Seismic performance of face loaded unreinforced masonry walls retrofitted using post-tensioning
    Ismail, N.
    Lazzarini, D.
    Laursen, P.
    Ingham, J.
    [J]. AUSTRALIAN JOURNAL OF STRUCTURAL ENGINEERING, 2010, 11 (03) : 243 - 252
  • [7] Experimental Assessment of Controlled Rocking Masonry Shear Walls without Post-tensioning
    Yassin, Ahmed
    Ezzeldin, Mohamed
    Wiebe, Lydell
    [J]. JOURNAL OF STRUCTURAL ENGINEERING, 2022, 148 (04)
  • [8] GROUTING POST-TENSIONING DUCTS
    不详
    [J]. CONCRETE CONSTRUCTION, 1983, 28 (04): : 337 - 339
  • [9] GROUTING OF POST-TENSIONING TENDONS
    SCHUPACK, M
    [J]. CIVIL ENGINEERING, 1978, 48 (03): : 72 - 73
  • [10] LARGE POST-TENSIONING TENDONS
    CARTER, BV
    [J]. JOURNAL PRESTRESSED CONCRETE INSTITUTE, 1972, 17 (06): : 70 - 71