Fully integrate d wearable micronee dle biosensing platform for wide-range and real-time continuous glucose monitoring

被引:6
|
作者
Li, Lei [1 ,2 ]
Zhou, Yujie [1 ,2 ]
Sun, Chenwei [1 ,2 ]
Zhou, Zhengming [3 ,4 ]
Zhang, Jieyu [1 ,2 ]
Xu, Yuanyuan [1 ,2 ]
Xiao, Xuanyu [1 ,2 ]
Deng, Hui [6 ]
Zhong, Yuting [1 ,2 ]
Li, Guoyuan [1 ,2 ]
Chen, Zhiyu [1 ,2 ]
Deng, Wei [5 ]
Hu, Xuefeng [6 ,7 ]
Wang, Yunbing [1 ,2 ,7 ]
机构
[1] Sichuan Univ, Natl Engn Res Ctr Biomat, Chengdu 610064, Sichuan, Peoples R China
[2] Sichuan Univ, Coll Biomed Engn, Chengdu 610065, Sichuan, Peoples R China
[3] Sichuan Univ, West China Sch Publ Hlth, Dept Nutr & Food Hyg, Chengdu 610041, Sichuan, Peoples R China
[4] Sichuan Univ, West China Hosp 4, Chengdu 610041, Sichuan, Peoples R China
[5] Chengdu Med Coll, Pidu Dist Peoples Hosp, Affiliated Hosp 3, Dept Orthoped, Chengdu 611730, Sichuan, Peoples R China
[6] Sichuan Univ, West China Sch Basic Med Sci & Forens Med, Chengdu 610041, Sichuan, Peoples R China
[7] 29 Wangjiang Rd, Chengdu, Peoples R China
关键词
Wearable biosensor; Continuous glucose monitoring; Microneedle; Interstitial fluid; Glutaraldehyde cross -linking; Prussian blue; PRUSSIAN BLUE; SENSOR; COMPOSITES; MANAGEMENT; STABILITY; ARRAYS;
D O I
10.1016/j.actbio.2023.12.044
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Wearable microneedle sensors for continuous glucose monitoring (CGM) have great potential for clinical impact by allowing access to large data sets to provide individualized treatment plans. To date, their development has been challenged by the accurate wide linear range tracking of interstitial fluid (ISF) glucose (Glu) levels. Here, we present a CGM platform consisting of a three -electrode microneedle electrochemical biosensor and a fully integrated radio -chemical analysis system. The long-term performance of the robust CGM on diabetic rats was achieved by electrodepositing Prussian blue (PB), and crosslinking glucose oxidase (GOx) and chitosan to form a 3D network using glutaraldehyde (GA). After redox by GOx, PB rapidly decomposes hydrogen peroxide and mediates charge transfer, while the 3D network and graphite powder provide enrichment and release sites for Glu and catalytic products, enabling a sensing range of 0.25-35 mM. Microneedle CGM has high sensitivity, good stability, and anti -interference ability. In diabetic rats, CGM can accurately monitor Glu levels in the ISF in real-time, which are highly consistent with levels measured by commercial Glu meters. These results indicate the feasibility and application prospects of the PB-based CGM for the clinical management of diabetes. Statement of Significance This study addresses the challenge of continuous glucose monitoring system design where the narrow linear range of sensing due to the miniaturization of sensors fails to meet the monitoring needs of clinical diabetic patients. This was achieved by utilizing a three-dimensional network of glutaraldehyde cross -linked glucose oxidase and chitosan. The unique topology of the 3D network provides a large number of sites for glucose enrichment and anchors the enzyme to the sensing medium and the conductive substrate through covalent bonding, successfully blocking the escape of the enzyme and the sensing medium and shortening the electron transfer and transmission path. (c) 2023 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:199 / 213
页数:15
相关论文
共 50 条
  • [21] DIABETES Under Control Real-Time Continuous Glucose Monitoring
    Ramchandani, Neesha
    Saadon, Yael
    Jornsay, Donna
    AMERICAN JOURNAL OF NURSING, 2010, 110 (04) : 60 - 63
  • [22] Is reimbursement for alerts and real-time continuous glucose monitoring needed?
    Norgaard, Kirsten
    Schmidt, Signe
    LANCET, 2021, 397 (10291): : 2230 - 2232
  • [23] Design and implementation of real-time continuous glucose monitoring instrument
    实时动态血糖监测器的设计与实现
    Liu, Hongying (liu_hongying@163.com), 2017, West China Hospital, Sichuan Institute of Biomedical Engineering (34):
  • [24] Real-Time Continuous Glucose Monitoring During the Coronavirus Disease 2019 Pandemic and Its Impact on Time in Range
    van der Linden, Joost
    Welsh, John B.
    Hirsch, Irl B.
    Garg, Satish K.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2021, 23 : S1 - S7
  • [25] Real-Time Wide-Range Carrier Frequency Offset Compensation by Multi-Thread PADE for Fully Softwarized Access Networks
    Suzuki, Takahiro
    Kim, Sang-Yuep
    Kani, Jun-Ichi
    Yoshida, Tomoaki
    IEEE ACCESS, 2024, 12 : 16915 - 16925
  • [26] Accuracy of real-time glucose values using continuous glucose monitoring:: the Guardian™ II continuous glucose monitoring system
    Schwartz, SL
    Buchea, O
    Shin, J
    Hoss, U
    Shah, R
    DIABETOLOGIA, 2004, 47 : A315 - A315
  • [27] Real-Time and Wide-Range 3D Shape Measurement Using Linear LED Fringe Projector
    Fujigaki, Motoharu
    2015 2ND INTERNATIONAL CONFERENCE ON OPTO-ELECTRONICS AND APPLIED OPTICS (IEM OPTRONIX), 2015,
  • [28] Wearable Wireless ECG Sensor with Cross-Platform Real-Time Monitoring
    Thanawattano, Chusak
    Pongthornseri, Ronachai
    Dumnin, Songphon
    2012 IEEE EMBS CONFERENCE ON BIOMEDICAL ENGINEERING AND SCIENCES (IECBES), 2012,
  • [29] A long lifetime and highly sensitive wearable microneedle sensor for the continuous real-time monitoring of glucose in interstitial fluid
    Yin, Sijie
    Yu, Zhiqiang
    Song, Ningning
    Guo, Zhanjun
    Li, Wei
    Ma, Jinhang
    Wang, Xiaoyan
    Liu, Junyao
    Liang, Minmin
    BIOSENSORS & BIOELECTRONICS, 2024, 244
  • [30] Wide-range and high-accuracy wireless sensor with self-humidity compensation for real-time ammonia monitoring
    Lv, Wen
    Yang, Jianhua
    Xu, Qingda
    Mehrez, Jaafar Abdul-Aziz
    Shi, Jia
    Quan, Wenjing
    Luo, Hanyu
    Zeng, Min
    Hu, Nantao
    Wang, Tao
    Wei, Hao
    Yang, Zhi
    NATURE COMMUNICATIONS, 2024, 15 (01)