Impact of Scleral Lens Front Surface Eccentricity on Visual Acuity, Contrast Sensitivity, and Higher-Order Aberrations in Eyes With Keratoconus

被引:1
|
作者
Badrinarayanan, Aparna [1 ]
Balakrishnan, Akshaya C. [1 ]
Dutta, Ronit [1 ]
Kumar, R. Mahesh [1 ]
Iqbal, Asif [1 ,2 ]
机构
[1] Sankara Nethralaya, Unit Med Res Fdn, Dept Contact Lens, Chennai, India
[2] Sankara Nethralaya Med Res Fdn, Dept Contact Lens, 18,Coll Rd, Chennai 600006, Tamilnadu, India
来源
关键词
Scleral lens; Keratoconus; Front surface eccentricity; Higher-order aberration; Visual acuity; Contrast sensitivity; CORNEAL TOPOGRAPHY; CLINICAL-OUTCOMES; REHABILITATION; ASPHERICITY; ANTERIOR;
D O I
10.1097/ICL.0000000000001007
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To investigate the effect of front surface eccentricity (FSE) of scleral lenses (SLs) on corrected distance visual acuity (CDVA), contrast sensitivity (CS), and higher-order aberrations (HOAs) in keratoconic eyes.Methods: Fifteen keratoconic eyes fitted with BostonSight SCLERAL lenses of different eccentricity values (FSE0=0, FSE1=0.30, and FSE2=0.60). CDVA, CS, and HOAs were measured at baseline and after 30 min of SL wear. CDVA and CS were measured with the Early Treatment Diabetic Retinopathy Study and Pelli-Robson chart, respectively, and iTrace aberrometer was used to evaluate the HOAs.Results: Baseline CDVA was 0.30 +/- 0.29, which significantly improved to 0.10 +/- 0.11, 0.05 +/- 0.06, and 0.05 +/- 0.08 logMAR with FSE0, FSE1, and FSE2, respectively (P<0.05). The post hoc showed no significant difference between eccentricities. Baseline CS was 1.19 +/- 0.47, which improved to 1.54 +/- 0.12, 1.59 +/- 0.10, and 1.60 +/- 0.11 with FSE0, FSE1, and FSE2, respectively (P<0.01), but post hoc showed no significant difference between eccentricities. A statistically significant reduction was found in HOAs when compared with baseline (P<0.01). Comparison between eccentricities showed a significant difference only between FSE0 and FSE1 for RMS coma (P=0.01) and RMS spherical aberrations (P=0.004) where FSE1 showed better performance in reducing HOAs compared with FSE0. HO-RMS, RMS secondary astigmatism, and RMS trefoil showed no significant difference between eccentricities, but FSE1 and FSE2 performed superior to FSE0.Conclusion: BostonSight SCLERAL lenses with varying eccentricities corrected a significant amount of HOAs and improved CDVA and CS in keratoconus patients. Practitioners should be aware of this distinct feature of SLs and use it as needed to improve visual performance.
引用
收藏
页码:374 / 378
页数:5
相关论文
共 50 条
  • [21] The impact of corneal higher-order aberrations on dynamic visual acuity post cataract surgery
    Wu, Tingyi
    Wang, Yuexin
    Li, Yuanting
    Li, Yuanhong
    Jiang, Xiaodan
    Li, Xuemin
    FRONTIERS IN NEUROSCIENCE, 2024, 18
  • [22] Higher-order aberrations 1 year after corneal collagen crosslinking for keratoconus and their independent effect on visual acuity
    Wisse, Robert P. L.
    Gadiot, Stijn
    Soeters, Nienke
    Godefrooij, Daniel A.
    Imhof, Saskia M.
    van der Lelij, Allegonda
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (07): : 1046 - 1052
  • [23] Effects of higher-order aberrations on contrast acuity as a function of light level
    Dalimier, Eugenie
    Dainty, Chris
    Barbur, John L.
    JOURNAL OF MODERN OPTICS, 2008, 55 (4-5) : 791 - 803
  • [24] Correlation between higher-order aberrations and visual acuity after crosslinking treatment for keratoconus: study of 90 cases
    Luc, Marie-Soline
    Maxime, Sot
    Francois, Julie
    Goetz, Christophe
    Ouamara, Nadia
    Perone, Jean-Marc
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [25] Mesopic Contrast Sensitivity and Ocular Higher-Order Aberrations in Eyes With Conventional Spherical Intraocular Lenses
    Ishii, Yuko
    Okamoto, Chikako
    Hiraoka, Takahiro
    Okamoto, Fumiki
    Oshika, Tetsuro
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009, 148 (02) : 298 - 302
  • [26] Wavefront-guided LASIK for Myopia: Effect on Visual Acuity, Contrast Sensitivity, and Higher Order Aberrations
    Keir, Nancy J.
    Simpson, Trefford
    Jones, Lyndon W.
    Fonn, Desmond
    JOURNAL OF REFRACTIVE SURGERY, 2009, 25 (06) : 524 - 533
  • [27] Higher-Order Aberrations Due to the Posterior Corneal Surface in Patients with Keratoconus
    Nakagawa, Tomoya
    Maeda, Naoyuki
    Kosaki, Ryo
    Hori, Yuichi
    Inoue, Tomoyuki
    Saika, Makoto
    Mihashi, Toshifumi
    Fujikado, Takashi
    Tano, Yasuo
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2009, 50 (06) : 2660 - 2665
  • [28] Visual outcomes and higher-order aberrations in eyes implanted with hybrid extended depth of focus intraocular lens
    Kenia, Vaishal P.
    Kenia, Raj V.
    Mudaliya, Laxmi
    Pirdankar, Onkar H.
    TAIWAN JOURNAL OF OPHTHALMOLOGY, 2023, 13 (03) : 341 - 345
  • [29] Effect of higher-order aberrations on visual function in keratoconic eyes with a rigid gas permeable contact lens
    Negishi, Kazuno
    Kumanomido, Takashi
    Utsumi, Yoshikazu
    Tsubota, Kazuo
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2007, 144 (06) : 924 - 929
  • [30] Effect of higher order aberrations on contrast sensitivity function in myopic eyes
    Feizi, Sepehr
    Karimian, Farid
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2009, 53 (04) : 414 - 419