CuBTC metal organic framework-based dispersive solid phase extraction of cyclosporine and tacrolimus from plasma samples prior to determination by high performance liquid chromatography-tandem mass spectrometry

被引:3
|
作者
Mogaddam, Mohammad Reza Afshar [1 ,2 ]
Khosrowshahi, Elnaz Marzi [1 ]
Farajzadeh, Mir Ali [3 ,4 ]
Nemati, Mahboob [1 ,5 ]
机构
[1] Tabriz Univ Med Sci, Food & Drug Safety Res Ctr, Tabriz, Iran
[2] Tabriz Univ Med Sci, Pharmaceut Anal Res Ctr, Tabriz, Iran
[3] Tabriz Univ, Fac Chem, Dept Analyt Chem, Tabriz, Iran
[4] Near East Univ, Engn Fac, Mersin 10, TR-99138 Nicosia, North Cyprus, Turkiye
[5] Tabriz Univ Med Sci, Fac Pharm, Pharmaceut & Food Control Dept, Tabriz, Iran
关键词
Metal organic framework; Dispersive solid phase extraction; Plasma; High performance liquid chromatography; tandem mass spectrometry; Immunosuppressive drugs; WHOLE-BLOOD; SIROLIMUS; IMMUNOSUPPRESSANTS; ASSAY;
D O I
10.1016/j.jchromb.2023.123692
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Immunosuppressive drugs are prescribed to reduce the immune system of persons who are undergoing organ transplants. The concentration of these drugs in blood and plasma samples must be accurately and precisely determined during immunosuppressive therapy due to their significant side effects. In this study, a metal organic framework-based dispersive solid phase extraction method was developed for the extraction of tacrolimus and cyclosporine from plasma samples before their determination by high performance liquid chromatography-tandem mass spectrometry. For this purpose, CuBTC metal organic framework nanoparticles were prepared by a hydrothermal approach and they were used as the sorbent in the extraction procedure. The adsorbed analytes were eluted by a suitable organic solvent and then more concentrated by evaporation of the eluate. All of the effective parameters of the method including sorbent amount, adsorption time, eluent type, desorption time, eluent volume, and sample solution pH were studied and optimized. They were obtained 5 mg, 5 min, acetone, 5 min, 300 mu L, and 5, respectively. Under optimal conditions, the developed method was validated and the data showed that the linear range, the limit of detection, the limit of quantification, the coefficient of determination, the enrichment factor, and relative standard deviation values were 1-1000 ng mL-1, 0.30 ng mL-1, 0.5 ng mL-1, 0.99, 15.6, and 5.8 % for tacrolimus and 0.8-500 ng mL-1, 0.25 ng mL-1, 0.4 ng mL-1, 0.99, 17, and 5.6 % for cyclosporine, respectively. Finally, the method was successfully used in the determination of the studied drugs in plasma samples.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Determination of 19 Kinds of Nonprotein Nitrogen Compounds in Powdered Formulas by Dispersive Solid Phase Extraction-High Performance Liquid Chromatography-Tandem Mass Spectrometry
    Zhao Shan-Zhen
    Yi Xiong-Hai
    Cheng Jia
    Pan Xiao-Bo
    Guo De-Hua
    Zhu Jian
    Deng Xiao-Jun
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2016, 44 (08) : 1227 - 1235
  • [42] Determination of neurotoxic shellfish poisoning toxins in shellfish by liquid chromatography-tandem mass spectrometry coupled with dispersive solid phase extraction
    Fang, Li
    Qiu, Fengmei
    HELIYON, 2023, 9 (11)
  • [43] Simultaneous determination of 25 pesticides in Zizania latifolia by dispersive solid-phase extraction and liquid chromatography-tandem mass spectrometry
    Xu, Feng
    Yu, Jia-yong
    Wang, Quan-sheng
    Fu, Yan
    Zhang, Hao
    Wu, Yin-liang
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [44] Simultaneous determination of five baicaleins in healthy product tablets by dispersive solid-phase extraction-high performance liquid chromatography-tandem mass spectrometry
    Cen Jianbin
    Liang Zhisen
    Ou Shuojun
    Huang Jiale
    Li Xiuying
    Lin Qinglan
    Chen Yuzhen
    Liu Xinjie
    Lin Senyu
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2020, 38 (06) : 672 - 678
  • [45] Simultaneous determination of 25 pesticides in Zizania latifolia by dispersive solid-phase extraction and liquid chromatography-tandem mass spectrometry
    Feng Xu
    Jia-yong Yu
    Quan-sheng Wang
    Yan Fu
    Hao Zhang
    Yin-liang Wu
    Scientific Reports, 9
  • [46] Simultaneous determination of sixteen amide fungicides in vegetables and fruits by dispersive solid phase extraction and liquid chromatography-tandem mass spectrometry
    Wu, Yin-Liang
    Chen, Ruo-Xia
    Zhu, Yong
    Zhao, Jian
    Yang, Ting
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 989 : 11 - 20
  • [47] Determination of methotrexate in environmental samples by solid phase extraction and high performance liquid chromatography: ultraviolet or tandem mass spectrometry detection?
    Turci, R
    Micoli, G
    Minoia, C
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2000, 14 (08) : 685 - 691
  • [48] Determination of Escitalopram in Human Plasma by High Performance Liquid Chromatography-Tandem Mass Spectrometry
    de Sousa, Carlos E. M.
    Bonifacio, Felipe N.
    Bedor, Danilo C. G.
    Silva, Thayse M.
    Ramos, Virna L. S.
    de Souza Filho, Jose H.
    Leal, Leila B.
    Oliveira, Amanda T. C.
    de Santana, Davi P.
    LATIN AMERICAN JOURNAL OF PHARMACY, 2012, 31 (02): : 310 - 314
  • [49] Determination of LBPT in human plasma by high performance liquid chromatography-tandem mass spectrometry
    Liu, Ming
    Wang, Hongyun
    Liu, Hongzhong
    Peng, Ao
    Yang, Fen
    Wang, Wenjie
    Zhu, Liya
    Huang, Haihong
    Jiang, Ji
    Hu, Pei
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 965 : 238 - 243
  • [50] Determination of Triazoles in Tea Samples Using Dispersive Solid Phase Extraction Combined with Dispersive Liquid–Liquid Microextraction Followed by Liquid Chromatography–Tandem Mass Spectrometry
    Yu Zhang
    Hui Xu
    Food Analytical Methods, 2014, 7 : 189 - 196