CuBTC metal organic framework-based dispersive solid phase extraction of cyclosporine and tacrolimus from plasma samples prior to determination by high performance liquid chromatography-tandem mass spectrometry

被引:3
|
作者
Mogaddam, Mohammad Reza Afshar [1 ,2 ]
Khosrowshahi, Elnaz Marzi [1 ]
Farajzadeh, Mir Ali [3 ,4 ]
Nemati, Mahboob [1 ,5 ]
机构
[1] Tabriz Univ Med Sci, Food & Drug Safety Res Ctr, Tabriz, Iran
[2] Tabriz Univ Med Sci, Pharmaceut Anal Res Ctr, Tabriz, Iran
[3] Tabriz Univ, Fac Chem, Dept Analyt Chem, Tabriz, Iran
[4] Near East Univ, Engn Fac, Mersin 10, TR-99138 Nicosia, North Cyprus, Turkiye
[5] Tabriz Univ Med Sci, Fac Pharm, Pharmaceut & Food Control Dept, Tabriz, Iran
关键词
Metal organic framework; Dispersive solid phase extraction; Plasma; High performance liquid chromatography; tandem mass spectrometry; Immunosuppressive drugs; WHOLE-BLOOD; SIROLIMUS; IMMUNOSUPPRESSANTS; ASSAY;
D O I
10.1016/j.jchromb.2023.123692
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Immunosuppressive drugs are prescribed to reduce the immune system of persons who are undergoing organ transplants. The concentration of these drugs in blood and plasma samples must be accurately and precisely determined during immunosuppressive therapy due to their significant side effects. In this study, a metal organic framework-based dispersive solid phase extraction method was developed for the extraction of tacrolimus and cyclosporine from plasma samples before their determination by high performance liquid chromatography-tandem mass spectrometry. For this purpose, CuBTC metal organic framework nanoparticles were prepared by a hydrothermal approach and they were used as the sorbent in the extraction procedure. The adsorbed analytes were eluted by a suitable organic solvent and then more concentrated by evaporation of the eluate. All of the effective parameters of the method including sorbent amount, adsorption time, eluent type, desorption time, eluent volume, and sample solution pH were studied and optimized. They were obtained 5 mg, 5 min, acetone, 5 min, 300 mu L, and 5, respectively. Under optimal conditions, the developed method was validated and the data showed that the linear range, the limit of detection, the limit of quantification, the coefficient of determination, the enrichment factor, and relative standard deviation values were 1-1000 ng mL-1, 0.30 ng mL-1, 0.5 ng mL-1, 0.99, 15.6, and 5.8 % for tacrolimus and 0.8-500 ng mL-1, 0.25 ng mL-1, 0.4 ng mL-1, 0.99, 17, and 5.6 % for cyclosporine, respectively. Finally, the method was successfully used in the determination of the studied drugs in plasma samples.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry Coupled with Solid Phase Extraction
    Xie Lin-Na
    Zhang Hai-Jing
    Hou Sha-Sha
    Zhu Ying
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2019, 47 (12) : 1967 - 1972
  • [32] A New High-Performance Liquid Chromatography-Tandem Mass Spectrometry Method Based on Dispersive Solid Phase Extraction for the Determination of the Mycotoxin Fusarin C in Corn Ears and Processed Corn Samples
    Kleigrewe, Karin
    Soehnel, Anna-Carina
    Humpf, Hans-Ulrich
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2011, 59 (19) : 10470 - 10476
  • [33] Determination of seven phenoxy acid herbicides in water by dispersive solid phase extraction-ultra performance liquid chromatography-tandem mass spectrometry based on cationic metal-organic framework mixed matrix membrane
    Ji Xuefeng
    Li Shuang
    Wu Gege
    Zhao Lin
    Ma Jiping
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2021, 39 (08) : 896 - 904
  • [34] Determination of five nonsteroidal anti-inflammatory drugs in water by dispersive solid phase extraction-ultra performance liquid chromatography-tandem mass spectrometry based on metal-organic framework composite aerogel
    Ling Huijuan
    Wu Gege
    Li Shuang
    Zhou Qian
    Li Chunxin
    Ma Jiping
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2022, 40 (04) : 323 - 332
  • [35] Metal-organic framework-based magnetic dispersive micro-solid-phase extraction for the gas chromatography-mass spectrometry determination of polycyclic aromatic compounds in water samples
    Fornari, Fabio
    Bianchi, Federica
    Riboni, Nicolo
    Casoli, Francesca
    Bacchi, Alessia
    Mazzeo, Paolo Pio
    Pelagatti, Paolo
    Careri, Maria
    JOURNAL OF CHROMATOGRAPHY A, 2022, 1671
  • [36] Determination of seven phenoxy carboxylic acid herbicides in water using dispersive solid phase extraction coupled with ultra-high performance liquid chromatography-tandem mass spectrometry based on metal-organic framework composite aerogel
    Zhang, Xin
    Wu, Gege
    Cui, Wenlian
    Li, Shuang
    Ma, Jiping
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2024, 42 (11) : 1042 - 1051
  • [37] Sesame oil determination by solid-phase extraction and liquid chromatography-tandem mass spectrometry
    Xinjing Dou
    Liangxiao Zhang
    Peiwu Li
    Huali Xie
    Huhu Lang
    Xiaomei Chen
    Li Yu
    Wen Zhang
    Qi Zhang
    Oil Crop Science, 2017, 2 (03) : 181 - 186
  • [38] Simultaneous determination of 11 quinolones in hotpot ingredients by dispersive solid-phase extraction and ultra performance liquid chromatography-tandem mass spectrometry
    Cao Peng
    Mou Yan
    Gao Fei
    Geng Jinpei
    Zhang Xiqing
    Sui Tao
    Liang Junni
    Sha Meilan
    Guan Lili
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2013, 31 (09) : 862 - 868
  • [39] Simultaneous determination of 13 organic pollutants in water samples by high performance liquid chromatography-tandem mass spectrometry
    Luo Birong
    Qian Shu
    Xie Zhenwei
    Yao Huan
    Xiong Jie
    Zhao Hong
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2015, 33 (07) : 740 - 745
  • [40] Determination of cylindrospermopsin, nodularin and microcystins in freshwater fish by dispersive solid phase extraction-liquid chromatography-tandem mass spectrometry
    Chen Lihui
    Jia Yuzhu
    Zhang Bin
    Pan Qiuren
    Chen Qinqin
    Cai Weipeng
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2019, 37 (07) : 723 - 728