A laser pistonphone designed for absolute calibration of infrasound sensors from 10 mHz up to 20 Hz

被引:9
|
作者
Rodrigues, D. [1 ]
Vincent, P. [2 ]
Barham, R. [3 ]
Larsonnier, F. [2 ]
Durand, S. [4 ]
机构
[1] Lab Commun Metrol LNE CNAM LCM, 29 Ave Roger Hennequin, F-78197 Trappes, France
[2] Commissariat Energie Atom & Energies Alternat CEA, DAM, DIF, F-91297 Arpajon, France
[3] Acoust Sensor Networks ASN, St Andrews Church, Cuckfield Lane, Warninglid RH17 5UB, England
[4] Le Mans Univ, UMR CNRS 6613, Univ Maine LAUM, Lab Acoust, Ave Olivier Messiaen, F-72085 Le Mans 9, France
基金
欧盟地平线“2020”;
关键词
infrasound; calibration; laser pistonphone; microphones; microbarometers; barometers; acoustics;
D O I
10.1088/1681-7575/aca0f3
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
There has been an increased demand for traceable calibrations at infrasonic frequencies in support of geophysical monitoring applications, an example being the Comprehensive Nuclear-Test-Ban Treaty Organization, which provides global international coverage for a nuclear testing ban, and requires the International Monitoring System. In this paper, a new laser pistonphone design is presented with the objective of establishing primary standards for sound pressure at very low frequencies down to 10 mHz. The piston is a modified accessorized loudspeaker driver whose diameter is equal to the diameter of the front pistonphone cavity. The volume velocity of the piston is measured through a laser interferometer and the current version was designed to have an upper frequency limit of 20 Hz, to overlap with the closed coupler reciprocity method of calibration. Particular attention has been given to the sealing to avoid pressure leakage loss. The dimensions of the front cavity were designed to allow the calibration of a large variety of sensors, including microphones, barometers, manometers and microbarometers. Examples of calibrations for several sensors are presented and also an uncertainty budget for the Bruel & Kj AE r type 4160 laboratory standard microphones, commonly used for primary calibrations. Finally, the metrological performance of the laser pistonphone is demonstrated by comparing the calibration results with those obtained with alternative methods.
引用
收藏
页数:12
相关论文
共 4 条
  • [1] A dedicated pistonphone for absolute calibration of infrasound sensors at very low frequencies
    He, Wen
    He, Longbiao
    Zhang, Fan
    Rong, Zuochao
    Jia, Shushi
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2016, 27 (02)
  • [2] A calculable pistonphone for the absolute calibration of hydrophones in the frequency range from 0.5 Hz to 250 Hz
    Malcher, Freya
    Ford, Ben
    Barham, Richard
    Robinson, Stephen
    Ward, Jake
    Wang, Lian
    Bridges, Angus
    Yacoot, Andrew
    Cheong, Sei-Him
    Rodrigues, Dominique
    Barrera-Figueroa, Salvador
    METROLOGIA, 2024, 61 (02)
  • [3] Investigation of sound pressure leakage effect for primary calibration down to 10-2 Hz using a laser pistonphone system
    Hirano, Koto
    Takahashi, Hironobu
    Yamada, Keisuke
    Nozato, Hideaki
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2024, 35 (05)
  • [4] Calibration methods and facilities for vector receivers using a laser Doppler vibrometer in the frequency range 20 Hz to 10 kHz
    Jia, Guanghui
    Chen, Yi
    Wang, Shiquan
    Yang, Liuqing
    Wang, Weiyin
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2021, 150 (03): : 1997 - 2005