Development of a certified reference material for the analysis of vitamins in multivitamin tablets

被引:1
|
作者
Lee, Joonhee [1 ]
Kim, Byungjoo [1 ]
Sim, Hee-Jung [2 ]
Seo, Dongwon [3 ]
Kwak, Byung-Man [4 ]
Won, Jongeun [4 ]
Lee, Sunyoung [1 ]
Baek, Song-Yee [1 ]
Han, Jeesoo [1 ]
机构
[1] Korea Res Inst Stand & Sci, Div Chem & Biol Metrol, Yuseong 34113, Daejeon, South Korea
[2] Korea Inst Toxicol, Gyeongnam Branch Inst, Environm Risk Assessment Res Div, Jinju Si 52834, Gyeongsangnam D, South Korea
[3] Korea Food Res Inst, Food Anal Res Ctr, Wanju Gun 55365, Jeolabuk Do, South Korea
[4] Namyang Dairy Prod Co, Food Safety Ctr, Sejong 30055, South Korea
关键词
Water-soluble vitamins; Isotope dilution method; Multivitamin tablets; Certified reference materials; Fat-soluble vitamins; PERFORMANCE LIQUID-CHROMATOGRAPHY; ORGANIC REFERENCE MATERIALS; MASS-BALANCE METHOD; ACCURATE DETERMINATION; PURITY ASSESSMENT; INFANT FORMULA; FOLIC-ACID; SPECTROMETRY; RIBOFLAVIN; MINERALS;
D O I
10.1186/s40543-023-00368-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Multivitamin tablet certified reference material (CRM, 108-10-019) was developed for the analysis of seven water-soluble vitamins, including thiamine, riboflavin, nicotinamide, pantothenic acid, pyridoxine, biotin, and folic acid. The CRM was prepared in powder form by grinding multivitamin tablets and then mixing, sieving, and bottling the powder. For the certification of each water-soluble vitamin, the isotope dilution mass spectrometry based on the liquid chromatography was applied. The methods for each analyte were validated by confirming the repeatability and reproducibility and by comparing with other CRMs. The property values and uncertainties for the vitamins were determined with 10 units from sample stored at - 20 degrees C. The homogeneity of each certified component was also examined in the range of 0.48-2.2%. All certified values for the seven water-soluble vitamins were stable for 3 or 6 years after the initial certification under storage conditions at - 20 degrees C. For fat-soluble vitamins, including retinol, alpha-tocopherol, cholecalciferol, and phylloquinone, two expert laboratories participated in analyses based on official methods, and the mean values of the reported results were assigned as reference values. The multivitamin tablet CRM (108-10-019) will be useful for validating analytical methods and for ensuring the quality of results for vitamin analysis in multivitamin tablets or similar products.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Evaluation of Cyanocobalamin in Multivitamin Tablets and Their Standard Reference Material 3280 by HPLC with Visible Detection
    Matsumoto, Teruki
    Takebayashi, Jun
    Ishimi, Yoshiko
    Ozawa, Chihiro
    Sano, Akira
    Hirota, Takashi
    Endoh, Kaori
    JOURNAL OF AOAC INTERNATIONAL, 2012, 95 (06) : 1609 - 1613
  • [22] Certification of Vitamins and Carotenoids in SRM 3280 Multivitamin/Multielement Tablets
    Sander, L. C.
    Sharpless, K. E.
    Wise, S. A.
    Nelson, B. C.
    Phinney, K. W.
    Porter, B. J.
    Rimmer, C. A.
    Thomas, J. B.
    Wood, L. J.
    Yen, J. H.
    Duewer, D. L.
    Atkinson, R.
    Chen, P.
    Goldschmidt, R.
    Wolf, W. R.
    Ho, I. -P.
    Betz, J. M.
    ANALYTICAL CHEMISTRY, 2011, 83 (01) : 99 - 108
  • [23] CERTIFIED REFERENCE MATERIAL (CRM) FOR STEEL ANALYSIS
    BRAUNER, J
    BOTTGER, D
    STAHL UND EISEN, 1986, 106 (10): : 583 - 588
  • [24] Development of a new chlorogenic acid certified reference material for food and drug analysis
    Yang, Dezhi
    Jiao, LingTai
    Zhang, Baoxi
    Du, Guanhua
    Lu, Yang
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2017, 140 : 169 - 173
  • [25] Analysis Methods for Development of Certified Reference Material (CRM) Zircon Minerals Synthesis
    Samin
    Sunanti, Susanna Tuning
    INDONESIAN JOURNAL OF CHEMISTRY, 2018, 18 (03) : 448 - 456
  • [26] Development of certified reference material of cerium-zirconium composite for chemical analysis
    Zhao, Yan
    Xie, Yanyan
    Bai, Xiaoyan
    Chen, Xiongfei
    Gao, Yan
    Fu, Na
    Xiao, Nana
    Chinese Journal of Analysis Laboratory, 2025, 44 (02) : 186 - 191
  • [27] Development of a certified reference material for the accurate analysis of the acrylamide content in infant formula
    Lee, Sunyoung
    Baek, Song-Yee
    Han, Jeesoo
    Lee, Joonhee
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2023, 415 (19) : 4805 - 4812
  • [28] Development of a new tetrandrine certified reference material for clinical chemistry and pharmaceutical analysis
    Yang, Dezhi
    Wang, Fengfeng
    Zhang, Li
    Lv, Yang
    ANALYTICAL METHODS, 2015, 7 (11) : 4763 - 4768
  • [29] Development of a certified reference material for the accurate analysis of the acrylamide content in infant formula
    Sunyoung Lee
    Song-Yee Baek
    Jeesoo Han
    Joonhee Lee
    Analytical and Bioanalytical Chemistry, 2023, 415 : 4805 - 4812
  • [30] Development of a new taurine purity certified reference material
    Chen, Weizhu
    Jin, Wenhui
    Fang, Hua
    Chen, Hui
    Chen, Xiaoying
    Zhang, Yiping
    Hong, Zhuan
    MICROCHEMICAL JOURNAL, 2022, 181