Numerical simulation of the blood flow through a pre-stenotic aneurysm in coronary artery: effects of varying heart rate

被引:1
|
作者
Udupa, Mahesh C. [1 ]
Saha, Sunanda [1 ,2 ]
Natarajan, Sekarapandian [3 ]
机构
[1] VIT Vellore, Dept Math, SAS, Vellore, Tamil Nadu, India
[2] VIT Vellore, Ctr Clean Environm, Vellore, Tamil Nadu, India
[3] VIT Vellore, Sch Mech Engn, Dept Thermal & Energy, Vellore, Tamil Nadu, India
关键词
Coronary artery diseases; computational fluid dynamics; oscillatory shear index; stenosis; aneurysm; heart rate; WALL SHEAR-STRESS; HEMODYNAMIC PARAMETERS; PULSATILE FLOW; STENOSIS; PRESSURE; ATHEROSCLEROSIS; TRANSITION; TRANSPORT; PATIENT; FLUID;
D O I
10.1080/10255842.2023.2297659
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The left anterior descending artery (LAD) is a significant coronary artery and a facilitator of oxygenated blood to the heart muscles. Thus, any occurrence of an aneurysm in LAD requires immediate medical attention. It is often inclined toward fatality if coupled with a blockage due to stenosis. Given the high relevance of understanding such models, invasive techniques under all parametric circumstances are hard to achieve. So, a theoretical approach with a cost-effective intervention of mathematical modeling becomes essential. In our current work, we analyze the model with the numerical technique of a modified form of SIMPLE pressure-correction based algorithm and perform parametric studies for the flow field with degree of stenosis, degree of aneurysm, heart rate, and distance separating aneurysm and stenosis as parameters. The study reveals a direct proportionality relation between the number of recirculation zones and heart rate through instantaneous streamline plots. Alongside this, the demonstration of an increase in the risk of rupture of the aneurysm with a decrease in the distance between stenosis and aneurysm, using the physical parameters associated with blood flow, is another key finding. Further, we examine the effect of the flow field on heat transfer and the consequent temperature profiles.
引用
收藏
页码:459 / 477
页数:19
相关论文
共 50 条
  • [31] Time-resolved simulation of blood flow through left anterior descending coronary artery: effect of varying extent of stenosis on hemodynamics
    Yinghong Zhao
    Huihui Wang
    Wenbing Chen
    Wenyue Sun
    Xianchao Yu
    Cunjie Sun
    Gang Hua
    BMC Cardiovascular Disorders, 23
  • [32] Slip effects on unsteady non-Newtonian blood flow through an inclined catheterized overlapping stenotic artery
    Zaman, Akbar
    Ali, Nasir
    Sajid, M.
    AIP ADVANCES, 2016, 6 (01):
  • [33] Numerical simulation of physiological blood flow in 2-way Coronary Artery Bypass Grafts
    Qiao, A
    Liu, YJ
    Li, SY
    Zhao, H
    JOURNAL OF BIOLOGICAL PHYSICS, 2005, 31 (02) : 161 - 182
  • [34] Numerical Simulation of Physiological Blood Flow in 2-way Coronary Artery Bypass Grafts
    Aike Qiao
    Youjun Liu
    Siyang Li
    Hu Zhao
    Journal of Biological Physics, 2005, 31 : 161 - 182
  • [35] Numerical simulation of blood flow through mechanical heart valves using meshless techniques
    Roldan, Alejandro
    Sweitzer, Nancy
    Osswald, Tim
    Chesler, Naomi
    PROCEEDING OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2007, 2007, : 725 - 726
  • [36] Numerical simulation of hemodynamic parameters and coronary blood flow during beating-heart coronary bypass surgery
    Ferrari, G
    Gu, YJ
    De Lazzari, C
    De Kroon, TL
    Elstrodt, JM
    Rakhorst, G
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2006, 29 (05): : 518 - 518
  • [37] Computational simulation of rheological blood flow containing hybrid nanoparticles in an inclined catheterized artery with stenotic, aneurysmal and slip effects
    Tripathi, Jayati
    Vasu, B.
    Beg, O. Anwar
    Gorla, Rama Subba Reddy
    Kameswaran, Peri K.
    COMPUTERS IN BIOLOGY AND MEDICINE, 2021, 139
  • [38] Numerical analysis of blood flow through a stenosed artery using a coupled multiscale simulation method
    Shim, EB
    Kamm, RD
    Heldt, T
    Mark, RG
    COMPUTERS IN CARDIOLOGY 2000, VOL 27, 2000, 27 : 219 - 222
  • [39] Effects of unsteadiness and non-Newtonian rheology on blood flow through a tapered time-variant stenotic artery
    Zaman, A.
    Ali, N.
    Sajid, M.
    Hayat, T.
    AIP ADVANCES, 2015, 5 (03):
  • [40] Numerical Analysis of Stenosis Geometry and Stent Effects on the Hemodynamics of Blood Flow Through the Artery
    Lu J.
    Wang J.
    Zhao W.
    Li D.
    Journal of The Institution of Engineers (India): Series C, 2024, 105 (03) : 671 - 681