Enhanced SpO2 estimation using explainable machine learning and neck photoplethysmography

被引:2
|
作者
Zhong, Yuhao [1 ]
Jatav, Ashish [1 ]
Afrin, Kahkashan [1 ]
Shivaram, Tejaswini [2 ]
Bukkapatnam, Satish T. S. [1 ]
机构
[1] Texas A&M Univ, Wm Michael Barnes 64 Dept Ind & Syst Engn, College Stn, TX 77840 USA
[2] Texas A&M Univ, Dept Elect & Comp Engn, College Stn, TX 77840 USA
基金
美国国家科学基金会;
关键词
Explainable machine learning; Neck reflectance photoplethysmogram (PPG); Subject heterogeneity; Subject inclusion-exclusion criteria; SpO(2 )estimation;
D O I
10.1016/j.artmed.2023.102685
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Reflectance-based photoplethysmogram (PPG) sensors provide flexible options of measuring sites for blood oxygen saturation (SpO(2)) measurement. But they are mostly limited by accuracy, especially when applied to different subjects, due to the diverse human characteristics (skin colors, hair density, etc.) and usage conditions of different sensor settings. This study addresses the estimation of SpO(2) at non-standard measuring sites employing reflectance-based sensors. It proposes an automated construction of subject inclusion-exclusion criteria for SpO(2) measuring devices, using a combination of unsupervised clustering, supervised regression, and model explanations. This is perhaps among the first adaptation of SHAP to explain the clusters gleaned from unsupervised learning methods. As a wellness application case study, we developed a pillow-based wearable device to collect reflectance PPGs from both the brachiocephalic and carotid arteries around the neck. The experiment was conducted on 33 subjects, each under totally 80 different sensor settings. The proposed approach addressed the variations of humans and devices, as well as the heterogeneous mapping between signals and SpO(2) values. It identified effective device settings and characteristics of their applicable subject groups (i.e., subject inclusion-exclusion criteria). Overall, it reduced the root mean squared error (RMSE) by 16%, compared to an empirical formula and a plain SpO(2) estimation model.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Machine learning based algorithms to impute PaO2 from SpO2 values and development of an online calculator
    Ren, Shuangxia
    Zupetic, Jill A.
    Tabary, Mohammadreza
    DeSensi, Rebecca
    Nouraie, Mehdi
    Lu, Xinghua
    Boyce, Richard D.
    Lee, Janet S.
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [22] Performance comparison of machine learning algorithms for the estimation of blood pressure using photoplethysmography
    Di Nisio, Attilio
    De Palma, Luisa
    Ragolia, Mattia Alessandro
    Lanzolla, Anna Maria Lucia
    Attivissimo, Filippo
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2025, 99
  • [23] Machine learning based algorithms to impute PaO2 from SpO2 values and development of an online calculator
    Shuangxia Ren
    Jill A. Zupetic
    Mohammadreza Tabary
    Rebecca DeSensi
    Mehdi Nouraie
    Xinghua Lu
    Richard D. Boyce
    Janet S. Lee
    Scientific Reports, 12
  • [24] Noncontact SpO2 Measurement Using Eulerian Video Magnification
    Galvao Rosa, Alessandra de Fatima
    Betini, Roberto Cesar
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2020, 69 (05) : 2120 - 2130
  • [25] A Deep Learning Approach to Estimate SpO2 from PPG Signals
    Koteska, Bojana
    Bodanova, Ana Madevska
    Mitrova, Hristina
    Sidorenko, Marija
    Lehocki, Fedor
    2022 9TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS RESEARCH AND APPLICATIONS, ICBRA 2022, 2022, : 142 - 148
  • [26] USING RESPIRATORY EFFORT AND SPO2 TO DETECT RESPIRATORY EVENTS
    Coronel, C.
    Wiesmeyr, C.
    Garn, H.
    Kohn, B.
    Wimmer, M.
    Mandl, M.
    Glos, M.
    Penzel, T.
    Kloesch, G.
    Stefanic-Kejik, A.
    Ock, M. B.
    Kaniusas, E.
    Seidel, S.
    SLEEP MEDICINE, 2019, 64 : S126 - S127
  • [27] Research on Multiple Spectral Ranges with Deep Learning for SpO2 Measurement
    Shen, Chih-Hsiung
    Chen, Wei-Lun
    Wu, Jung-Jie
    SENSORS, 2022, 22 (01)
  • [28] Design of Pulse Oximetry Based on Photoplethysmography and Beat Rate Signal Using DS-100 Probe Sensor for SpO2 Measurement
    Umar, Lazuardi
    Firmansyah, Irfan
    Setiadi, Rahmondia Nanda
    2018 3RD INTERNATIONAL SEMINAR ON SENSORS, INSTRUMENTATION, MEASUREMENT AND METROLOGY (ISSIMM), 2018, : 25 - 29
  • [29] Frequency Domain SpO2 Estimation Based on Multichannel Photoplethysmographic Measurements at the Sternum
    Vetter, R.
    Rossini, L.
    Ridolfi, A.
    Sola, J.
    Chetelat, O.
    Correvon, M.
    Krauss, J.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 4: IMAGE PROCESSING, BIOSIGNAL PROCESSING, MODELLING AND SIMULATION, BIOMECHANICS, 2010, 25 : 326 - 329
  • [30] Optimization of Sleep Apnea Detection using SpO2 and ANN
    Mostafa, Sheikh Shanawaz
    Carvalho, Joao Paulo
    Morgado-Dias, Fernando
    Ravelo-Garcia, Antonio
    2017 XXVI INTERNATIONAL CONFERENCE ON INFORMATION, COMMUNICATION AND AUTOMATION TECHNOLOGIES (ICAT), 2017,