Model tests on penetration and seepage behaviors of a scaled suction caisson in sand

被引:2
|
作者
Liang, Hao [1 ]
Wu, Yuqi [1 ]
Li, Dayong [1 ]
Zhao, Jipeng [1 ]
机构
[1] China Univ Petr East China, Coll Pipeline & Civil Engn, 66 West Changjiang Rd, Qingdao 266580, Peoples R China
基金
中国博士后科学基金; 中国国家自然科学基金;
关键词
Scaled suction caisson; Model test; Penetration resistance; Seepage; DESIGN PROCEDURES; INSTALLATION; FOUNDATIONS; RESISTANCE;
D O I
10.1016/j.apor.2023.103751
中图分类号
P75 [海洋工程];
学科分类号
0814 ; 081505 ; 0824 ; 082401 ;
摘要
This study presents a new type of the offshore mooring foundation named as a scaled suction caisson (SSC), of which concept is inspired from the kinetic function of the scaled skin of snakes. When the SSC penetrates into the soil, the penetration resistance effectively decreases due to decreasing the friction force between the soil and sidewall. However, the bearing capacity increases due to increasing the friction force between the soil and sidewall when the SSC is subjected to pull load. A series of the suction-assisted installation model tests are carried out to investigate the penetration and seepage behaviors of the scaled suction caisson in sand. The result indicates that penetration resistance of the SSC increases with decreasing the aspect ratio H1/D1 of the scale structure. For example, when the aspect ratio H1/D1 equals 10, the penetration resistance decreases by 3.1% compared with the traditional suction caisson. And as the aspect ratio H1/D1 decreases from 10 to 5, the penetration resistance increases by 9.9%. In spite of these cases, it shows that reasonable selection of H1/D1 is helpful or not an obstacle to penetration. Furthermore, it is found that the height of the soil plug effectively decreases by the intermittent suction-assisted installation. The formula of calculating the penetration resistance of the SSC during suction-assisted installation is presented in terms of the excess pore water pressure distribution inside and outside the sidewall. The calculation results agree well with the model test results, indicating that the proposed formula of calculating the penetration resistance is reliable.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] ADVANCED APPROACHES FOR COUPLED DEFORMATION-SEEPAGE-ANALYSES OF SUCTION CAISSON INSTALLATION
    Stapelfeldt, Marc
    Bienen, Britta
    Grabe, Juergen
    PROCEEDINGS OF THE ASME 36TH INTERNATIONAL CONFERENCE ON OCEAN, OFFSHORE AND ARCTIC ENGINEERING, 2017, VOL 9, 2017,
  • [42] Penetration characteristics of suction caisson for offshore wind power: a field study
    Zhu, Xun
    Chen, Zheng
    Guan, Yun-Fei
    Ni, Pengpeng
    Liu, Yong-Gang
    Li, Wen-Xuan
    Han, Xun
    Fan, Kai-Fang
    CANADIAN GEOTECHNICAL JOURNAL, 2024, : 2364 - 2375
  • [43] Soil conditions and bounds to suction during the installation of caisson foundations in sand
    Harireche, Ouahid
    Mehravar, Moura
    Alani, Amir M.
    OCEAN ENGINEERING, 2014, 88 : 164 - 173
  • [44] Simulation of Suction Caisson Penetration in Seabed Using an Adaptive Mesh Technique
    Zeinoddini, M.
    Mousavi, S. A.
    Abdi, M. R.
    PROCEEDINGS OF THE TWELFTH EAST ASIA-PACIFIC CONFERENCE ON STRUCTURAL ENGINEERING AND CONSTRUCTION (EASEC12), 2011, 14 : 1721 - 1728
  • [45] Components of suction caisson capacity measured in axial pullout tests
    Luke, AM
    Rauch, AF
    Olson, RE
    Mecham, EC
    OCEAN ENGINEERING, 2005, 32 (07) : 878 - 891
  • [46] Experimental studies on sand plug formation in suction caisson during extraction
    Zhang, Yukun
    Li, Dayong
    Chen, Fuquan
    MARINE GEORESOURCES & GEOTECHNOLOGY, 2018, 36 (07) : 795 - 804
  • [47] Experimental Studies on Shear Behavior of Sand-Suction Caisson Wall Interface under Variable Normal Load and Penetration Rate
    Yifan Li
    Dayong Li
    Yuqi Wu
    Yukun Zhang
    KSCE Journal of Civil Engineering, 2023, 27 : 2766 - 2777
  • [48] Failure envelope of suction caisson anchors subjected to combined loadings in sand
    Cheng, L.
    Hossain, M. S.
    Hu, Y.
    Kim, Y. H.
    Ullah, S. N.
    APPLIED OCEAN RESEARCH, 2021, 114
  • [49] Inclined loading of suction caisson anchors in calcareous sand with particle breakage
    Cheng, L.
    Hossain, M. S.
    Hu, Y.
    Ullah, S. N.
    Kim, Y. H.
    COMPUTERS AND GEOTECHNICS, 2024, 173
  • [50] Calculation method for maximum bearing capacity of suction caisson foundation in sand
    Li, B. (lbershui@seu.edu.cn), 1600, Southeast University (42):