Soil conditions and bounds to suction during the installation of caisson foundations in sand

被引:39
|
作者
Harireche, Ouahid [1 ]
Mehravar, Moura [1 ]
Alani, Amir M. [1 ]
机构
[1] Univ Greenwich, Medway Sch Engn, Dept Civil Engn, Chatham ME4 4TB, Kent, England
关键词
Caisson foundation; Installation in sand; Normalised geometry; Piping condition; Failure modes; PENETRATION;
D O I
10.1016/j.oceaneng.2014.06.033
中图分类号
U6 [水路运输]; P75 [海洋工程];
学科分类号
0814 ; 081505 ; 0824 ; 082401 ;
摘要
Suction installation of caisson foundations is widely adopted in the oil offshore industry. When such foundations are installed in sand, seepage conditions are known to play a pivotal role in the installation process. Pressure gradients generated by the imposed suction inside the caisson cavity cause an overall reduction in the lateral soil pressure acting on the caisson wall as well as in the tip resistance. This transient loosening of soil around the caisson wall facilitates caisson penetration into the seabed. However, these effects must be controlled to avoid soil failure due to critical conditions such as piping or loss of soil shear strength, which may cause the installation procedure to fail due to instability of the soil plug trapped inside the caisson cavity. In this paper, we endeavour to study these effects based on the analysis of the normalised seepage problem, assuming the installation process to take place in homogeneous sand. We first investigate the effects of seepage conditions on soil resistance to caisson penetration with a particular focus on how frictional resistance and tip resistance are differently affected. We then consider modes of failure due to soil piping inside the caisson cavity and sliding of soil mass in a failure mechanism where the soil plug inside the caisson cavity is pushed upward. Based on this study, some insight is gained into the critical conditions for piping. These conditions evolve during the installation process as the penetration depth increases under an increasing suction. Upper and lower bounds are also estimated for the critical suction based on an assumed mode of failure using a simple mechanism of rigid blocks. By comparing these modes of failure we conclude that piping is not always the most critical condition. The critical mode of failure for a given soil may change during the installation process and this is highlighted by comparing the critical suction for piping to the suction upper and lower bounds related to shear failure. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:164 / 173
页数:10
相关论文
共 50 条
  • [1] Variation of suction pressure during caisson installation in sand
    Tran, M. N.
    Randolph, M. F.
    [J]. GEOTECHNIQUE, 2008, 58 (01): : 1 - 11
  • [2] Variation of suction pressure during caisson installation in sand DISCUSSION
    Villalobos, F. A.
    [J]. GEOTECHNIQUE, 2009, 59 (01): : 73 - 74
  • [3] Centrifuge experiment and numerical simulation of suction caisson installation in sand
    Wang, He
    Wang, Rui
    Zhang, JianMin
    [J]. Zhongguo Kexue Jishu Kexue/Scientia Sinica Technologica, 2022, 52 (12): : 1792 - 1801
  • [4] Suction caisson installation in sand with isotropic permeability varying with depth
    Harireche, Ouahid
    Mehravar, Moura
    Alani, Amir M.
    [J]. APPLIED OCEAN RESEARCH, 2013, 43 : 256 - 263
  • [5] Centrifuge tests investigating the effect of suction caisson installation in dense sand on the state of the soil plug
    Stapelfeldt, M.
    Bienen, B.
    Grabe, J.
    [J]. PHYSICAL MODELLING IN GEOTECHNICS, VOL 1, 2018, : 669 - 674
  • [6] Penetration behaviors and soil plug developing of the scaled suction caisson during installation
    Liang, Hao
    Li, Dayong
    Zhang, Yukun
    [J]. OCEAN ENGINEERING, 2024, 310
  • [7] Experimental studies on suction-assisted installation of the modified suction caisson in dense sand
    Zhang, Yukun
    Li, Dayong
    Bai, Yun
    [J]. APPLIED OCEAN RESEARCH, 2022, 124
  • [8] Evaluation of Seepage Flow during Installation of Suction Caisson Foundation in Homogeneous Sand and Sand Overlaying Inclined Clay
    Faizi, Koohyar
    Hojjati, Aryan
    Faramarzi, Asaad
    Dirar, Samir
    [J]. GEO-CONGRESS 2022: DEEP FOUNDATIONS, EARTH RETENTION, AND UNDERGROUND CONSTRUCTION, 2022, 332 : 309 - 318
  • [9] Evaluating installation of suction caisson in sand via accounting for soil seepage-deformation coupled process
    Huang, Maosong
    Zhao, Li
    Luo, Xinquan
    Shi, Zhenhao
    Shen, Kanmin
    Wang, Bin
    [J]. OCEAN ENGINEERING, 2024, 310
  • [10] Seepage Induced Soil Failure and its Mitigation During Suction Caisson Installation in Silt
    Wang, Lizhong
    Yu, Luqing
    Guo, Zhen
    Wang, Zhenyu
    [J]. JOURNAL OF OFFSHORE MECHANICS AND ARCTIC ENGINEERING-TRANSACTIONS OF THE ASME, 2014, 136 (01):