Three-dimensional joint surface orientation does not correlate with two-dimensional coronal joint line orientation in knee osteoarthritis: Three-dimensional analysis of upright computed tomography

被引:2
|
作者
Sasaki, Ryo [1 ]
Niki, Yasuo [1 ,3 ]
Kaneda, Kazuya [1 ]
Yamada, Yoshitake [2 ]
Nagura, Takeo [1 ]
Nakamura, Masaya [1 ]
Jinzaki, Masahiro [2 ]
机构
[1] Keio Univ, Sch Med, Dept Orthopaed Surg, Tokyo, Japan
[2] Keio Univ, Sch Med, Dept Radiol, Tokyo, Japan
[3] Keio Univ, Sch Med, Dept Orthopaed Surg, 35 Shinanomachi Shinjuku, Tokyo 1608582, Japan
来源
KNEE | 2023年 / 43卷
基金
日本学术振兴会;
关键词
Osteoarthritis; Upright CT; Tibial joint line; Three-dimensional evaluation; Varus alignment; KINEMATICALLY ALIGNED TKA; POSTERIOR TIBIAL SLOPE; ALIGNMENT; BIOMECHANICS; VARUS; ARTHROPLASTY; ASSOCIATION; GEOMETRY; AXIS;
D O I
10.1016/j.knee.2023.05.001
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Two-dimensional (2D) coronal joint line orientation on radiography under weight-bearing conditions has been widely used in evaluating knee osteoarthritis (OA). However, the effects of tibial rotation remain unknown. The present study aimed to newly define three-dimensional (3D) joint surface orientation relative to the floor as an unchangeable 3D angle unaffected by tibial rotation using upright computed tomography (CT), and to investigate correlations between 3D and 2D parameters in knee OA.Methods: Sixty-six knees in 38 patients with varus knee OA underwent standing hip-to -ankle digital radiography and upright CT. The 2D parameters measured on radiographs included femorotibial angle (FTA), tibial joint line angle (TJLA), lateral distal femoral angle (LDFA), medial proximal tibial angle (MPTA), and joint line convergence angle (JLCA). The 3D inner product angle between vectors of the tibial joint surface and the floor from CT was defined as the 3D joint surface-floor angle.Results: Mean 3D joint surface-floor angle was 6.0 +/- 3.6 degrees. No correlation was identified between 3D joint surface-floor angle and 2D joint line parameters, even though FTA corre-lated substantially with 2D joint line parameters. No significant differences in 3D joint surface-floor angle were identified among Coronal Plane Alignment of the Knee (CPAK) types.Conclusions: The 3D joint surface orientation did not correlate with 2D coronal joint line orientation and was unaffected by CPAK classification types. This finding suggests that cur-rent 2D evaluations should be reconsidered for a better understanding of true knee joint line orientation.(c) 2023 Elsevier B.V. All rights reserved.
引用
收藏
页码:10 / 17
页数:8
相关论文
共 50 条
  • [21] Two-Dimensional and Three-Dimensional Cephalometry Using Cone Beam Computed Tomography Scans
    Michele, Cassetta
    Federica, Altieri
    Roberto, Di Giorgio
    Alessandro, Silvestri
    JOURNAL OF CRANIOFACIAL SURGERY, 2015, 26 (04) : E311 - E315
  • [22] A comparison of two-dimensional radiography and three-dimensional computed tomography in angular cephalometric measurements
    Nalcaci, R.
    Ozturk, F.
    Sokucu, O.
    DENTOMAXILLOFACIAL RADIOLOGY, 2010, 39 (02) : 100 - 106
  • [23] Two-dimensional and three-dimensional computed tomography for the classification and characterisation of tibial plateau fractures
    Doornberg, Job N.
    Rademakers, Maarten V.
    van den Bekerom, Michel P.
    Kerkhoffs, Gino M.
    Ahn, Jaimo
    Steller, E. Ph.
    Kloen, Peter
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2011, 42 (12): : 1416 - 1425
  • [24] Computed Tomography Measurements as a Standard of Exophthalmos? Two-Dimensional Versus Three-Dimensional Techniques
    Guo, Jie
    Qian, Jiang
    Yuan, Yifei
    CURRENT EYE RESEARCH, 2018, 43 (05) : 647 - 653
  • [25] Three-dimensional analysis of cricoarytenoid joint motion
    Wang, RC
    LARYNGOSCOPE, 1998, 108 (04): : 1 - 17
  • [26] IN VIVO THREE-DIMENSIONAL ANALYSIS OF THE FACET JOINT SURFACE CENTER
    Ishihara, Y.
    Orias, Espinoza A. A.
    An, H. S.
    Simon, P.
    Andersson, G. B.
    Inoue, N.
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE 2011, PTS A AND B, 2011, : 855 - 856
  • [27] Three-Dimensional Volume Rendering in Computed Tomography for Evaluation of the Temporomandibular Joint in Dogs
    Novales, Manuel
    Lucena, Rosario
    Hernandez, Eduardo M.
    Ginel, Pedro J.
    Fernandez, Jesus M.
    Blanco, Beatriz
    ANIMALS, 2023, 13 (20):
  • [28] Three-dimensional computed tomography evaluation of the ulnocarpal joint under stress loading
    Park, Ho Youn
    Kwak, Dai-Soon
    Park, Il-Jung
    Lee, Jin-Woo
    Kim, Seung Hyo
    Lee, Joo-Yup
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2024,
  • [29] Three-dimensional pelvimetry by computed tomography
    Lenhard, M.
    Johnson, T.
    Weckbach, S.
    Nikolaou, K.
    Friese, K.
    Hasbargen, U.
    RADIOLOGIA MEDICA, 2009, 114 (05): : 827 - 834
  • [30] Reliability of classification of ring and little finger carpometacarpal joint fracture subluxations: a comparison between two-dimensional computed tomography and three-dimensional computed tomography classifications
    Kim, J. H.
    Kwon, S. -S.
    Moon, S. J.
    Choe, J. S.
    Kwak, H. I.
    Lee, S. Y.
    Le, H. J.
    Kim, J. Y.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2016, 41 (04) : 448 - 452