Novel integration between propane pre-cooled mixed refrigerant LNG process and concentrated solar power system based on supercritical CO2 power cycle

被引:3
|
作者
Sleiti, Ahmad K. [1 ]
Al-Ammari, Wahib A. [1 ]
机构
[1] Qatar Univ, Coll Engn, Dept Mech & Ind Engn, Doha, Qatar
关键词
Propane pre-cooled mixed refrigerant; (C3MR); LNG; Concentrated solar power; Thermoeconomic analysis; Exergy analysis; SupercriticalCO(2) power cycles; GAS LIQUEFACTION PROCESS; THERMODYNAMIC ANALYSIS; MULTIOBJECTIVE OPTIMIZATION; EXERGOECONOMIC ANALYSIS; BRAYTON CYCLES; RANKINE-CYCLE; DESIGN; ENERGY; CONFIGURATION; TECHNOLOGIES;
D O I
10.1016/j.egyr.2023.04.012
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Liquefaction of natural gas (LNG) is an energy-intensive process with large CO2 emissions. This study addresses these problems by introducing a novel hybrid integration between the propane pre-cooled mixed-refrigerant (C3MR) liquefaction process and concentrated solar power (CSP), utilizing an intercooled supercritical CO2 power block. The proposed system is designed to minimize or eliminate the need for thermal energy storage (TES) and reduce CO2 emissions while providing economic benefits. These benefits are obtained mainly by recovering the cold energy of the flash-gas of the C3MR process through the precooling process of the sCO(2) cycle. Then, the flash-gas is stored and combusted (using an auxiliary heater (AH)) at nighttime or when CSP is insufficient to meet the power demand. Five integration cases are evaluated from energetic, exergetic, economic, and environmental points of view: the sCO(2) cycle is driven by CSP and its thermal energy storage (TES) without AH in Case-1, by CSP+TES+AH in Case-2 to Case-4 with different contribution from TES and AH, and by CSP+AH without TES in Case-5. In addition, this study optimizes the operating parameters of the hybrid system to further enhance its economic and environmental benefits. The proposed system reduces the CSP field size, minimizes or eliminates the need for TES, and reduces or eliminates CO2 emissions. The optimized results show that Case-2 and Case-5 reduced the levelized cost of electricity from 14.16(sic)/kWh to 10.35(sic)/kWh and 8.19(sic)/kWh, respectively, and reduced the CO2 emissions by 86% and 36%. This study contributes to the field by introducing a novel hybrid integration between the C3MR process and CSP system, providing thorough evaluations of its performance and benefits, and providing significant benefits to the decarbonization strategies of LNG and other industrial processes. (c) 2023 The Author(s). Published by Elsevier Ltd. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
引用
收藏
页码:4872 / 4892
页数:21
相关论文
共 50 条
  • [21] DYNAMIC MODEL OF SUPERCRITICAL CO2 BRAYTON CYCLES DRIVEN BY CONCENTRATED SOLAR POWER
    Couso, Gregory Berthet
    Vicencio, Rodrigo Barraza
    Padilla, Richardo Vasquez
    Too, Yen Chean Soo
    Pye, John
    PROCEEDINGS OF THE ASME 11TH INTERNATIONAL CONFERENCE ON ENERGY SUSTAINABILITY, 2017, 2017,
  • [22] Design, Fabrication, and Partial Characterization of a Solar Receiver and Air-Cooled Heat Exchanger for a Concentrated Solar Power Supercritical CO2 Testbed
    Nobles-Lookingbill, Danielle
    Sahm, Aaron
    Hurt, Rick
    Boehm, Robert
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2020, 142 (06):
  • [23] Effect of cooling system design on the performance of the recompression CO2 cycle for concentrated solar power application
    Ehsan, M. Monjurul
    Duniam, Sam
    Li, Jishun
    Guan, Zhiqiang
    Gurgenci, Hal
    Klimenko, Alexander
    ENERGY, 2019, 180 : 480 - 494
  • [24] Analysis of a graphite foam-NaCl latent heat storage system for supercritical CO2 power cycles for concentrated solar power
    Singh, Dileep
    Zhao, Weihuan
    Yu, Wenhua
    France, David M.
    Kim, Taeil
    SOLAR ENERGY, 2015, 118 : 232 - 242
  • [25] A review on supercritical CO2 and CO2-based mixture in power cycle
    Deng, Qinghua
    Liu, Anqi
    Li, Jun
    Feng, Zhenping
    ENERGY CONVERSION AND MANAGEMENT, 2025, 324
  • [26] Off-design operation of the dry-cooled supercritical CO2 power cycle
    Lock, Andrew
    Bone, Viv
    ENERGY CONVERSION AND MANAGEMENT, 2022, 251
  • [27] Investigation of thermodynamic performances of particle/supercritical CO2 2 fluidized bed heat exchanger integrated with supercritical CO2 2 recompression Brayton cycle for concentrated solar power
    Cu, Wenkai
    Fang, Jiabin
    Guo, Xiaodie
    Wei, Jinjia
    Zheng, Nan
    Chen, Kang
    Zhou, Zhi
    ENERGY CONVERSION AND MANAGEMENT, 2024, 315
  • [28] Multi-objective optimization of a novel supercritical CO2 cycle-based combined cycle for solar power tower plants integrated with SOFC and LNG cold energy and regasification
    Taheri, Muhammad Hadi
    Khani, Leyla
    Mohammadpourfard, Mousa
    Aminfar, Habib
    Akkurt, Gulden Gokcen
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2022, 46 (09) : 12082 - 12107
  • [29] Dynamic analysis of concentrated solar supercritical CO2-based power generation closed-loop cycle
    Osorio, Julian D.
    Hovsapian, Rob
    Ordonez, Juan C.
    APPLIED THERMAL ENGINEERING, 2016, 93 : 920 - 934
  • [30] Analyses of Thermal Performance of Solar Power Tower Station Based on a Supercritical CO2 Brayton Cycle
    Fang, Lijun
    Li, Yang
    Yang, Xue
    Yang, Zeliang
    JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME, 2020, 142 (03):