Related Substances Method Development and Validation of Axitinib, Zanubrutinib and Upadacitinib Using RP-HPLC and its Degradation Products were Characterized by Using LC-MS/MS

被引:3
|
作者
Syed, Ibrahim Baje [1 ]
Nannapaneni, Madhavi [1 ,2 ]
机构
[1] Acharya Nagarjuna Univ, JKC Coll Guntur, Dept Chem, Guntur, Andhra Pradesh, India
[2] Acharya Nagarjuna Univ, JKC Coll, Dept Chem, Guntur 522510, Andhra Pradesh, India
关键词
Mobile phase; X-bridge column; Validation; ICH guidelines; ANGIOGENESIS; INHIBITORS; AG-013736; GROWTH;
D O I
10.5530/223097131696
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Background: Axitinib was used to treat carcinoma of renal cells and Upadacitinib was used to treat rheumatoid arthritis and Zanubrutinib used as an anti cancer medication for mantle cell lymphoma. In the current application, Zanubrutinib, Upadacitinib and Axitinib and their associated substances will be developed and validated. Materials and Methods: The optimised method includes the Zanubrutinib, Upadacitinib and Axitinib gradient elution and associated flow rates with dimensions of 1 mL/min and phenyl column X-bridge (150 x 4.6 mm, 3.5 mu). A mobile phase was employed with 1.2 g of Hexane sulphonic acid of pH-2.5 adjusted with ortho-phosphoric acid (buffer) and acetonitrile. Zanubrutinib, Upadacitinib and Axitinib were separated from their associated substances for a total run time of 60 min. The approach developed has been validated in accordance with the ICH guidelines. Results: The test concentration LOD and LOQ were established for both drugs and for their impurities. The diagrams that were drawn were straightforward with an R2 regression coefficient > 0.999. As part of the method validation, recovery, specificity, linearity, accuracy, robustness was determined and the results were found to be within an acceptable range. Conclusion: HPLC was used to validate the method in terms of accuracy, linearity, method precision, accuracy, limit of detection, limit of quantification, robustness, and degradation, and LC-MS/MS was used to characterise the degradation products. The system was validated in all of these aspects.
引用
收藏
页码:113 / 121
页数:9
相关论文
共 50 条
  • [31] Separation, identification and characterization of stress degradation products of bortezomib using HPLC and LC-MS
    Reddy, C. Purushotham
    Ramakrishna, K.
    Rao, K. M. V. Narayana
    EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2021, 27 (2-4) : 115 - 125
  • [32] Development and Validation of a RP-HPLC Method for the Estimation of Netilmicin Sulfate and its Related Substances using Charged Aerosol Detection
    Joseph, Arul
    Patel, Shrina
    Rustum, Abu
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2010, 48 (07) : 607 - 612
  • [33] Development And Validation of a LC-MS Compatible Method for Quantification of Degradation Impurities of Clofazimine Using UHPLC
    Murty, Nagulakonda Naga Veera Venkata Sri Surya Narayana
    Bhattacharjee, Akash
    Krishnamurthy, Tatikonda
    Rao, Muguda Ravi Prasada
    Rao, Gollapalli Nageswara
    CURRENT PHARMACEUTICAL ANALYSIS, 2020, 16 (07) : 856 - 866
  • [34] SEPARATION, IDENTIFICATION AND QUANTITATION OF DEGRADANTS OF TOPOTECAN AND ITS RELATED IMPURITIES IN TOPOTECAN INJECTION BY RP-HPLC AND LC-MS
    Raghu, Nandan Srinivasan
    Reddy, Y. Ramachandra
    Naresh, V.
    Rao, V. Suryanarayana
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2011, 34 (07) : 548 - 578
  • [35] Development of stability-indicating method for separation and characterization of benidipine forced degradation products using LC-MS/MS
    Kushwah, Bhoopendra Singh
    Thummar, Mohit M.
    Yadav, Amrej Singh
    Dhiman, Vivek
    Samanthula, Gananadhamu
    BIOMEDICAL CHROMATOGRAPHY, 2023, 37 (01)
  • [36] Development of Novel RP-HPLC Method for Separation and Estimation of Critical Geometric Isomer and Other Related Impurities of Tafluprost Drug Substance and Identification of Major Degradation Compounds by Using LC-MS
    Sreenivasulu, J.
    Ramana, P. Venkata
    Reddy, G. Sampath Kumar
    Rakesh, M.
    Nagaraju, Ch. V. S.
    Rajan, S. Thirumalai
    Eswaraiah, S.
    Kishore, M.
    Ramakrishna, M.
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2016, 54 (08) : 1397 - 1407
  • [37] LC-MS/MS Characterization of Forced Degradation Products of Repaglinide Quality by Design Approach for Stability-Indicating LC Method Development and Validation for Degradation Products
    Kancherla, Prasad
    Srinivas, Keesari
    Alegete, Pallavi
    Albaseer, Saeed. S.
    ANALYTICAL CHEMISTRY LETTERS, 2020, 10 (06) : 740 - 757
  • [38] Pharmacokinetics of Schizandrin and Its Pharmaceutical Products Assessed Using a Validated LC-MS/MS Method
    Li, Chi-Lin
    Cheng, Yung-Yi
    Hsieh, Chen-Hsi
    Tsai, Tung-Hu
    MOLECULES, 2018, 23 (01):
  • [39] Validation and Development of a Method for Identification and Stability Analysis of Delafloxacin Separation Using LC-MS/MS
    Sarbudeen, M.
    Abbaraju, V. D. N. Kumar
    Padmalatha, K.
    Kodali, Unati Sai
    Chinnamaneni, Satya Vani
    Mandava, Bhuvantej
    Rao, Mandava Venkata Basaveswarao
    ORIENTAL JOURNAL OF CHEMISTRY, 2024, 40 (01) : 95 - 101
  • [40] Bioanalytical method development and validation of a novel antiseizure agent Cenobamate using LC-MS/MS
    Rao, Yamarthi Venkateswara
    Shaik, Rasheed Ahemad
    Chimakurthy, Jithendra
    INTERNATIONAL JOURNAL OF NANOTECHNOLOGY, 2023, 20 (1-4) : 63 - 74