Related Substances Method Development and Validation of Axitinib, Zanubrutinib and Upadacitinib Using RP-HPLC and its Degradation Products were Characterized by Using LC-MS/MS

被引:3
|
作者
Syed, Ibrahim Baje [1 ]
Nannapaneni, Madhavi [1 ,2 ]
机构
[1] Acharya Nagarjuna Univ, JKC Coll Guntur, Dept Chem, Guntur, Andhra Pradesh, India
[2] Acharya Nagarjuna Univ, JKC Coll, Dept Chem, Guntur 522510, Andhra Pradesh, India
关键词
Mobile phase; X-bridge column; Validation; ICH guidelines; ANGIOGENESIS; INHIBITORS; AG-013736; GROWTH;
D O I
10.5530/223097131696
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Background: Axitinib was used to treat carcinoma of renal cells and Upadacitinib was used to treat rheumatoid arthritis and Zanubrutinib used as an anti cancer medication for mantle cell lymphoma. In the current application, Zanubrutinib, Upadacitinib and Axitinib and their associated substances will be developed and validated. Materials and Methods: The optimised method includes the Zanubrutinib, Upadacitinib and Axitinib gradient elution and associated flow rates with dimensions of 1 mL/min and phenyl column X-bridge (150 x 4.6 mm, 3.5 mu). A mobile phase was employed with 1.2 g of Hexane sulphonic acid of pH-2.5 adjusted with ortho-phosphoric acid (buffer) and acetonitrile. Zanubrutinib, Upadacitinib and Axitinib were separated from their associated substances for a total run time of 60 min. The approach developed has been validated in accordance with the ICH guidelines. Results: The test concentration LOD and LOQ were established for both drugs and for their impurities. The diagrams that were drawn were straightforward with an R2 regression coefficient > 0.999. As part of the method validation, recovery, specificity, linearity, accuracy, robustness was determined and the results were found to be within an acceptable range. Conclusion: HPLC was used to validate the method in terms of accuracy, linearity, method precision, accuracy, limit of detection, limit of quantification, robustness, and degradation, and LC-MS/MS was used to characterise the degradation products. The system was validated in all of these aspects.
引用
收藏
页码:113 / 121
页数:9
相关论文
共 50 条
  • [21] Determination of degradation products of sumatriptan succinate using LC-MS and LC-MS-MS
    Xu, XH
    Bartlett, MG
    Stewart, JT
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2001, 26 (03) : 367 - 377
  • [22] Stability-Indicating Related Substances HPLC Method for Droxidopa and Characterization of Related Substances Using LC-MS and NMR
    Kumar, Thangarathinam
    Ramya, Mohandass
    Xavier, S. J. Arockiasamy
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2016, 54 (10) : 1761 - 1770
  • [23] Development and validation of novel RP-HPLC method for midostaurin determination using analytical quality by design approach from regulatory perspective and determination of major degradation compounds of midostaurin using LC-MS
    Saddala, Madhu Prakash Reddy
    Konduru, Naresh
    Gundla, Rambabu
    Kowtharapu, Leela Prasad
    BIOMEDICAL CHROMATOGRAPHY, 2022, 36 (12)
  • [24] Characterization of Elvitegravir and Its Related Impurities Using ESI-LC-MS, NMR Techniques, Method Development and Validation of Its Related Substances by HPLC Method
    Elumalai, Sambandan
    Senthilkumar, Sellappan
    Srikanth, Mamidala
    Nishtala, Venkata Bharat
    Thenmozhi, Kathavarayan
    CHROMATOGRAPHIA, 2024, 87 (04) : 227 - 248
  • [25] BIO-ANALYTICAL METHOD DEVELOPMENT AND VALIDATION FOR OMEPRAZOLE USING LC-MS/MS
    Vijayaraghavan, R.
    Jayababu, G.
    Prasad, R.
    Thirugnanam, P. E.
    Shivkumar, Gayathri
    Sriraam, V. T.
    Kumar, G. Ramesh
    INTERNATIONAL JOURNAL OF PHARMACEUTICAL SCIENCES AND RESEARCH, 2011, 2 (09): : 2475 - 2481
  • [26] Method Development and Validation for Determination of Voglibose in Tablet Formulation Using LC-MS/MS
    Rajput, Mithlesh
    Dahiya, Meenakshi
    Kumari, Premlata
    Kalra, Kamini
    Aggarwal, Manjeet
    Khandal, R. K.
    E-JOURNAL OF CHEMISTRY, 2011, 8 (04) : 1770 - 1783
  • [27] Stability indicating LC-MS/MS method and validation of Selexipag impurities and identification of its force degradation products
    Shah, Pranavkumar
    Hadiyal, Sanjay
    Dhaduk, Bhavin
    RESULTS IN CHEMISTRY, 2023, 6
  • [28] LC-MS/MS characterization of the forced degradation products of ezetemibe: Development and validation of a stability -indicating UPLC method
    Kancherla, Prasad
    Velpuri, Venkatappaiah
    Alegete, Pallavi
    Albaseer, Saeed S.
    Khagga, Mukkanti
    Das, Parthasaradhi
    JOURNAL OF TAIBAH UNIVERSITY FOR SCIENCE, 2016, 10 (01): : 148 - 160
  • [29] Identification of degradation impurities in aripiprazole oral solution using LC-MS and development of validated stability indicating method for assay and content of two preservatives by RP-HPLC
    Krishna, M. V. V. N. Murali
    Rao, Sumathi V.
    Venugopal, N. V. S.
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2017, 40 (14) : 741 - 750
  • [30] ANALYTICAL METHOD DEVELOPMENT & VALIDATION FOR RELATED SUBSTANCES IN DIPYRIDAMOLE BY RP-HPLC
    Menaka, T.
    Kuber, B. Ramya
    INTERNATIONAL JOURNAL OF PHARMACEUTICAL SCIENCES AND RESEARCH, 2020, 11 (04): : 1823 - 1830