Related Substances Method Development and Validation of Axitinib, Zanubrutinib and Upadacitinib Using RP-HPLC and its Degradation Products were Characterized by Using LC-MS/MS

被引:3
|
作者
Syed, Ibrahim Baje [1 ]
Nannapaneni, Madhavi [1 ,2 ]
机构
[1] Acharya Nagarjuna Univ, JKC Coll Guntur, Dept Chem, Guntur, Andhra Pradesh, India
[2] Acharya Nagarjuna Univ, JKC Coll, Dept Chem, Guntur 522510, Andhra Pradesh, India
关键词
Mobile phase; X-bridge column; Validation; ICH guidelines; ANGIOGENESIS; INHIBITORS; AG-013736; GROWTH;
D O I
10.5530/223097131696
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Background: Axitinib was used to treat carcinoma of renal cells and Upadacitinib was used to treat rheumatoid arthritis and Zanubrutinib used as an anti cancer medication for mantle cell lymphoma. In the current application, Zanubrutinib, Upadacitinib and Axitinib and their associated substances will be developed and validated. Materials and Methods: The optimised method includes the Zanubrutinib, Upadacitinib and Axitinib gradient elution and associated flow rates with dimensions of 1 mL/min and phenyl column X-bridge (150 x 4.6 mm, 3.5 mu). A mobile phase was employed with 1.2 g of Hexane sulphonic acid of pH-2.5 adjusted with ortho-phosphoric acid (buffer) and acetonitrile. Zanubrutinib, Upadacitinib and Axitinib were separated from their associated substances for a total run time of 60 min. The approach developed has been validated in accordance with the ICH guidelines. Results: The test concentration LOD and LOQ were established for both drugs and for their impurities. The diagrams that were drawn were straightforward with an R2 regression coefficient > 0.999. As part of the method validation, recovery, specificity, linearity, accuracy, robustness was determined and the results were found to be within an acceptable range. Conclusion: HPLC was used to validate the method in terms of accuracy, linearity, method precision, accuracy, limit of detection, limit of quantification, robustness, and degradation, and LC-MS/MS was used to characterise the degradation products. The system was validated in all of these aspects.
引用
收藏
页码:113 / 121
页数:9
相关论文
共 50 条
  • [1] LC-MS/MS characterization of forced degradation products of ambrisentan: development and validation of a stability-indicating RP-HPLC method
    Ramisetti, Nageswara Rao
    Kuntamukkala, Ramakrishna
    NEW JOURNAL OF CHEMISTRY, 2014, 38 (07) : 3050 - 3061
  • [2] A Validated Stability Indicating RP-HPLC Method for Valganciclovir, Identification and Characterization of Forced Degradation Products of Valganciclovir Using LC-MS/MS
    Sawant, S.
    Barge, V.
    ACTA CHROMATOGRAPHICA, 2014, 26 (01) : 29 - 42
  • [3] A Validated Stability Indicating RP-HPLC Method for Nabumetone, Identification and Characterization of Forced Degradation Products of Nabumetone Using LC-MS/MS
    Sawant, Sanjay
    Barge, Vijaya
    ASIAN JOURNAL OF CHEMISTRY, 2013, 25 (11) : 6203 - 6208
  • [4] Studies on forced degradation of oxcarbazepine using LC-MS compatible stability indicating RP-HPLC method
    Raghavi, K.
    Sindhura, M.
    Prashanthi, R.
    Nalluri, Buchi N.
    Journal of Chemical and Pharmaceutical Research, 2012, 4 (08) : 3885 - 3893
  • [5] Stability Indicating RP-HPLC Method by QbD Approach and LC-MS Characterization of Degradation Products of Mifepristone
    Chandarana, Chandni
    Juwarwala, Isha
    Prajapati, Parixit
    Patel, Jaimin Kumar
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2025, 63 (04)
  • [6] Stability-indicating HPLC method development and validation of rivaroxaban impurities and identification of forced degradation products using LC-MS/MS
    Cholleti, Vijaykumar
    Kumar, Yalavarti Ravindra
    Pasula, Aparna
    Surya, Prakash Rao Pydimarry
    BIOMEDICAL CHROMATOGRAPHY, 2022, 36 (09)
  • [7] Novel RP-HPLC method for simultaneous determination of dapagliflozin and teneligliptin in tablet formulation and identification of degradation products by LC-MS/MS
    Kashyap, Thummar
    Honey, Kevat
    Priyanka, Vadher
    Mihir, Jesur
    FUTURE JOURNAL OF PHARMACEUTICAL SCIENCES, 2024, 10 (01)
  • [8] Isolation and characterization of a degradation product of mexiletine hydrochloride using FT-IR, LC-MS and NMR: method development and validation of stability indicating RP-HPLC method for quantification of characterized impurity
    Muppavarapu, Venkatarao
    Challa, Gangu Naidu
    Gande, Mukteeshwar
    Billa, Praveen Reddy
    Beepala, Sateesh Kumar
    ANALYTICAL CHEMISTRY LETTERS, 2024, 14 (05) : 723 - 737
  • [9] Development and Validation of a Stability-Indicating Related Substances RP-HPLC Method for Anagliptin and its Degradation Products
    Rajendra S. Chavan
    Abdul Ahad
    Rajendra Phase
    Qasim Ullah
    Sabreena Yameen
    Pathan Mohd Arif
    Pharmaceutical Chemistry Journal, 2023, 57 : 1314 - 1322
  • [10] Development and Validation of a Stability-Indicating Related Substances RP-HPLC Method for Anagliptin and its Degradation Products
    Chavan, Rajendra S.
    Ahad, Abdul
    Phase, Rajendra
    Ullah, Qasim
    Yameen, Sabreena
    Arif, Pathan Mohd
    PHARMACEUTICAL CHEMISTRY JOURNAL, 2023, 57 (08) : 1314 - 1322