Life cycle cost and environmental assessment of CO2 utilization in the beverage industry: A natural gas-fired power plant equipped with post-combustion CO2 capture

被引:9
|
作者
Hosseini, Seyed Mohsen [1 ]
Aslani, Alireza [1 ,2 ]
Kasaeian, Alibakhsh [1 ]
机构
[1] Univ Tehran, Fac New Sci & Technol, Dept Renewable Energies & Environm, Tehran, Iran
[2] Univ Tehran, Fac New Sci & Technol, North Kargar St, Tehran, Iran
关键词
Life cycle assessment; Natural gas power plant; CO2 capture and utilization; Soft drinks; CARBON-DIOXIDE; STORAGE;
D O I
10.1016/j.egyr.2022.11.200
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Besat is a natural gas-fired steam-turbine power plant in Tehran, Iran's only power station equipped with a monoethanolamine-based post-combustion CO2 capture unit (PCCU). The PCCU operates at a low recovery rate of 4.7% and produces 58 t-CO2/day. Captured CO2 is encapsulated and sold to beverage companies for carbonated soft drink production. Before developing this CO2 capture and utilization (CCU) route, a beverage company like ZamZam produced CO2 on-site, capturing CO2 from flue gas of diesel-fired boilers using a 95%-efficient absorption-refrigeration unit. This paper conducts an attributional, comparative life-cycle assessment/costing of applying the CCU technology to supply the beverage industry with CO2. ReCiPe, cumulative energy demand, and AWARE impact assessment methods are adopted to assess changes in the life-cycle economic, energy, and environmental impacts of electricity, liquid CO2, and carbonated water supply chains with the CCU route. As per findings, the CCU route significantly improves the sustainability profile of liquid CO2 supply for carbonated water production. Compared to on-site production, the CCU route reduces the average economic, energy, and environmental impacts of liquid CO2 supply by 55, 44, and 62%, respectively. However, the figures for carbonated-water production are reduced by only 10.1, 0.85, and 0.77%, respectively, since associated impacts primarily result from citric acid and polyethylene terephthalate value chains rather than liquid CO2. The CCU route, in comparison, increases most environmental burdens of electricity generation. With an efficiency of 4.7%, the PCCU reduces the global warming potential of electricity generation by 6.22% while increasing average toxicity-and eutrophication-related impacts by 55 and 30%, respectively, and production costs by 8%.
引用
收藏
页码:414 / 436
页数:23
相关论文
共 50 条
  • [21] Coal-fired power plant with calcium oxide carbonation for post-combustion CO2 capture
    Romano, Matteo
    GREENHOUSE GAS CONTROL TECHNOLOGIES 9, 2009, 1 (01): : 1099 - 1106
  • [22] A review of efficiency penalty in a coal-fired power plant with post-combustion CO2 capture
    Goto, Kazuya
    Yogo, Katsunori
    Higashii, Takayuki
    APPLIED ENERGY, 2013, 111 : 710 - 720
  • [23] On the off-design of a natural gas-fired combined cycle with CO2 capture
    Fredriksson Moller, Bjorn
    Genrup, Magnus
    Assadi, Mohsen
    ENERGY, 2007, 32 (04) : 353 - 359
  • [24] On the off-design of a natural gas-fired combined cycle with CO2 capture
    Möller, BF
    Genrup, M
    Assadi, M
    Proceedings of ECOS 2005, Vols 1-3: SHAPING OUR FUTURE ENERGY SYSTEMS, 2005, : 811 - 818
  • [25] Life cycle modelling of fossil fuel power generation with post-combustion CO2 capture
    Korre, Anna
    Nie, Zhenggang
    Durucan, Sevket
    INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2010, 4 (02) : 289 - 300
  • [26] Life Cycle Assessment of applying CO2 post-combustion capture to the Spanish cement production
    Garcia-Gusano, Diego
    Garrain, Daniel
    Herrera, Israel
    Cabal, Helena
    Lechon, Yolanda
    JOURNAL OF CLEANER PRODUCTION, 2015, 104 : 328 - 338
  • [27] Gas-fired chemical looping combustion with supercritical CO2 cycle
    Khallaghi, Navid
    Hanak, Dawid P.
    Manovic, Vasilije
    APPLIED ENERGY, 2019, 249 : 237 - 244
  • [28] MODELING OF THE CO2 CAPTURE IN POST-COMBUSTION
    Amann, Jean-Marc
    Descamps, Cathy
    Kanniche, Mohamed
    Bouallou, Chakib
    SCIENTIFIC STUDY AND RESEARCH-CHEMISTRY AND CHEMICAL ENGINEERING BIOTECHNOLOGY FOOD INDUSTRY, 2007, 8 (01): : 77 - 90
  • [29] Overview Post-combustion CO2 capture
    Romeo, L. M.
    Bolea, I.
    BOLETIN DEL GRUPO ESPANOL DEL CARBON, 2015, (35): : 8 - 11
  • [30] Assessment of Membrane Performance for Post-Combustion CO2 Capture
    Liu, Liang
    Lee, Jung Hyun
    Han, Sang Hoon
    Ha, Seong Yong
    Chen, George Q.
    Kentish, Sandra E.
    Yeo, Jeong-Gu
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2022, 61 (01) : 777 - 785