Life cycle cost and environmental assessment of CO2 utilization in the beverage industry: A natural gas-fired power plant equipped with post-combustion CO2 capture

被引:9
|
作者
Hosseini, Seyed Mohsen [1 ]
Aslani, Alireza [1 ,2 ]
Kasaeian, Alibakhsh [1 ]
机构
[1] Univ Tehran, Fac New Sci & Technol, Dept Renewable Energies & Environm, Tehran, Iran
[2] Univ Tehran, Fac New Sci & Technol, North Kargar St, Tehran, Iran
关键词
Life cycle assessment; Natural gas power plant; CO2 capture and utilization; Soft drinks; CARBON-DIOXIDE; STORAGE;
D O I
10.1016/j.egyr.2022.11.200
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Besat is a natural gas-fired steam-turbine power plant in Tehran, Iran's only power station equipped with a monoethanolamine-based post-combustion CO2 capture unit (PCCU). The PCCU operates at a low recovery rate of 4.7% and produces 58 t-CO2/day. Captured CO2 is encapsulated and sold to beverage companies for carbonated soft drink production. Before developing this CO2 capture and utilization (CCU) route, a beverage company like ZamZam produced CO2 on-site, capturing CO2 from flue gas of diesel-fired boilers using a 95%-efficient absorption-refrigeration unit. This paper conducts an attributional, comparative life-cycle assessment/costing of applying the CCU technology to supply the beverage industry with CO2. ReCiPe, cumulative energy demand, and AWARE impact assessment methods are adopted to assess changes in the life-cycle economic, energy, and environmental impacts of electricity, liquid CO2, and carbonated water supply chains with the CCU route. As per findings, the CCU route significantly improves the sustainability profile of liquid CO2 supply for carbonated water production. Compared to on-site production, the CCU route reduces the average economic, energy, and environmental impacts of liquid CO2 supply by 55, 44, and 62%, respectively. However, the figures for carbonated-water production are reduced by only 10.1, 0.85, and 0.77%, respectively, since associated impacts primarily result from citric acid and polyethylene terephthalate value chains rather than liquid CO2. The CCU route, in comparison, increases most environmental burdens of electricity generation. With an efficiency of 4.7%, the PCCU reduces the global warming potential of electricity generation by 6.22% while increasing average toxicity-and eutrophication-related impacts by 55 and 30%, respectively, and production costs by 8%.
引用
收藏
页码:414 / 436
页数:23
相关论文
共 50 条
  • [1] Thermodynamic analysis on post-combustion CO2 capture of natural-gas-fired power plant
    Amrollahi, Zeinab
    Ertesvag, Ivar S.
    Bolland, Olav
    INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2011, 5 (03) : 422 - 426
  • [2] Integration of low-temperature transcritical CO2 Rankine cycle in natural gas-fired combined cycle (NGCC) with post-combustion CO2 capture
    Ystad, P. A. Marchioro
    Lakew, A. A.
    Bolland, O.
    INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2013, 12 : 213 - 219
  • [3] Preliminary Performance and Cost Evaluation of Four Alternative Technologies for Post-Combustion CO2 Capture in Natural Gas-Fired Power Plants
    Gatti, Manuele
    Martelli, Emanuele
    Di Bona, Daniele
    Gabba, Marco
    Scaccabarozzi, Roberto
    Spinelli, Maurizio
    Vigano, Federico
    Consonni, Stefano
    ENERGIES, 2020, 13 (03)
  • [5] Evaluation of natural gas combined cycle power plant for post-combustion CO2 capture integration
    Biliyok, Chechet
    Yeung, Hoi
    INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2013, 19 : 396 - 405
  • [6] Technologies for increasing CO2 concentration in exhaust gas from natural gas-fired power production with post-combustion, amine-based CO2 capture
    Li, Hailong
    Ditaranto, Mario
    Berstad, David
    ENERGY, 2011, 36 (02) : 1124 - 1133
  • [7] Dynamic Simulation and Control of Post-combustion CO2 Capture with MEA in a Gas Fired Power Plant
    Mechleri, Evgenia D.
    Biliyok, Chechet
    Thornhill, Nina F.
    24TH EUROPEAN SYMPOSIUM ON COMPUTER AIDED PROCESS ENGINEERING, PTS A AND B, 2014, 33 : 619 - 624
  • [8] Life cycle assessment of a pulverized coal power plant with post-combustion capture, transport and storage of CO2
    Koornneef, Joris
    van Keulen, Tim
    Faaij, Andre
    Turkenburg, Wim
    INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2008, 2 (04) : 448 - 467
  • [9] Natural gas fired combined cycle power plant with CO2 capture
    Shao, Yulin, 1600, Pergamon Press Inc, Tarrytown, NY, United States (36):
  • [10] Heat integration of natural gas combined cycle power plant integrated with post-combustion CO2 capture and compression
    Luo, Xiaobo
    Wang, Meihong
    Chen, Jian
    FUEL, 2015, 151 : 110 - 117