The Value of Circulating Tumor Cells and Tumor Markers Detection in Lung Cancer Diagnosis

被引:0
|
作者
Guo, Sumin [1 ]
Chen, Jingyu [2 ]
Hu, Po [3 ]
Li, Chen [3 ]
Wang, Xiang [3 ]
Chen, Ning [4 ]
Sun, Jiale [5 ]
Wang, Yongfeng [3 ]
Wang, Jianling [3 ]
Gu, Weikuan [6 ]
Wu, Shucai [1 ,7 ,8 ,9 ]
机构
[1] Hebei Med Univ, Dept Internal Med, Shijiazhuang, Hebei, Peoples R China
[2] China Acad Chinese Med Sci, Xiyuan Hosp, Dept Chinese Med Internal Med, Beijing, Peoples R China
[3] Hebei Chest Hosp, Lung Canc Prevent & Res Ctr Hebei Prov, Dept Oncol, Shijiazhuang, Hebei, Peoples R China
[4] Hebei Chest Hosp, Lung Canc Prevent & Res Ctr Hebei Prov, Dept Pathol, Shijiazhuang, Hebei, Peoples R China
[5] Hebei North Univ, Coll Lab Med, Zhangjiakou, Hebei, Peoples R China
[6] Univ Tennessee Hlth Sci Ctr, Dept Orthoped Surg & BME Campbell Clin, Memphis, TN USA
[7] Hebei Chest Hosp, Lung Canc Prevent & Res Ctr Hebei Prov, Dept Internal Med, Shijiazhuang, Hebei, Peoples R China
[8] Hebei Med Univ, Dept Internal Med, Shijiazhuang 050017, Hebei, Peoples R China
[9] Hebei Chest Hosp, Lung Canc Prevent & Res Ctr Hebei Prov, Dept Internal Med, Shijiazhuang 050041, Hebei, Peoples R China
关键词
microfluidic chip detection; circulating tumor cells; lung cancer; diagnosis;
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Objective: Circulating tumor cells are complete tumor cells with multi-scale analysis values that present a high potential for lung cancer diagnosis. To enhance the accuracy of lung cancer diagnosis, we detected circulating tumor cells by the innovated conical micro filter integrated microfluidic system. Methods: We recruited 45 subjects of study, including 22 lung cancer patients, 2 precancerous patients, the control group including 14 healthy participants, and 7 patients with lung benign lesions in this prospective study. We calculated the area under the receiver operating characteristic curve of circulating tumor cells, cytokeratin19 fragment, carcinoma embryonic antigen, squamous cell carcinoma, neuron-specific enolase, and their combination, respectively, while compared the circulating tumor cells levels between vein blood and arterial blood. A conical shape filter embedded in a microfluidic chip was used to improve the detection capability of circulating tumor cells. Results: The study indicated that the sensitivity, specificity, positive predictive value, and negative predictive value of circulating tumor cells detection were 81.8%, 90.5%, 90.0%, and 82.6%, respectively. The circulating tumor cells level of lung cancer patient was significantly higher than that of the control group (P < .05). The area under the curve of circulating tumor cells, cytokeratin19 fragment, carcinoma embryonic antigen, squamous cell carcinoma, and neuron-specific enolase alone was 0.838, 0.760, 0.705, 0.614, and 0.636, respectively. The combination area under the curve of the 4 tumor markers (cytokeratin19 fragment, carcinoma embryonic antigen, squamous cell carcinoma, and neuron-specific enolase) was 0.805 less than that of circulating tumor cells alone. Together, the total area under the curve of circulating tumor cell and the 4 tumor markers were 0.847, showing the highest area under the curve value among all biomarkers. In addition, this study found that there was no significant difference in positive rate of circulating tumor cell between arterial and venous blood samples. Conclusion: The circulating tumor cells detection technology by conical micro filter integrated microfluidic could be used for lung cancer diagnosis with high sensitivity and specificity. Complementary combination of circulating tumor cells and conventional 4 lung cancer markers could enhance the clinical application accuracy. Venous blood should be used as a routine sample for circulating tumor cells detections.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Association of inflammatory and tumor markers with circulating tumor cells in metastatic breast cancer
    Lohmann, A. E.
    Chang, M.
    Dowling, R. J. O.
    Ennis, M.
    Amir, E.
    Elser, C.
    Brezden-Masley, C.
    Vandenberg, T.
    Lee, E.
    Fazae, K.
    Stambolic, V.
    Goodwin, P. J.
    CANCER RESEARCH, 2016, 76
  • [42] Value of Auto-Fluorescence Spectrum Combined with Tumor Markers in Diagnosis of Lung Cancer
    Wu Yong-jun
    Hao Yan-hong
    Wu Wei-chao
    Wu Yi-ming
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2009, 29 (10) : 2787 - 2791
  • [43] Tumor markers as an aid in the histological diagnosis of lung cancer
    Molina, R.
    Auge, J. M.
    Filella, X.
    Marrades, R.
    Vinolas, N.
    Molins, L.
    Agusti, A.
    TUMOR BIOLOGY, 2012, 33 : 74 - 74
  • [44] TUMOR MARKERS IN LUNG CANCER, A TOOL FOR EARLY DIAGNOSIS?
    Molina, R.
    Marrades, R. M.
    Auge, J. M.
    Escudero, J. M.
    Vinolas, N.
    Reguart, N.
    Ramirez, J.
    Filella, X.
    Molins, L.
    Agusti, A.
    ANTICANCER RESEARCH, 2014, 34 (10) : 6066 - 6066
  • [45] Performance evaluation of detecting circulating tumor cells and tumor cells in bronchoalveolar lavage fluid in diagnosis of peripheral lung cancer
    Zhong, Chang-Hao
    Tong, Da
    Zhou, Zi-Qing
    Su, Zhu-Quan
    Luo, Yu-Long
    Xing, Jia
    Bai, Ya-Li
    Guo, Su-Jie
    Li, Shi-Yue
    JOURNAL OF THORACIC DISEASE, 2018, 10 : S830 - S837
  • [46] IMPROVED LUNG CANCER DIAGNOSIS BY THE COMBINATION OF TUMOR MARKERS
    Molina, R.
    Leon, A.
    Trape, J.
    Garrido, A.
    Auge, J. M.
    Filella, X.
    de la Torre, P.
    Escudero, J. M.
    Blavia, R.
    Perich, D.
    TUMOR BIOLOGY, 2010, 31 : S123 - S123
  • [47] Circulating Tumor DNA Detection Technology and Its Application Value in Cancer Diagnosis and Treatment
    Zhang, Jie-Jie
    Niu, Chun-Yan
    Dong, Lian-Hua
    Yang, Yi
    Li, Hui-Jie
    Yang, Jing-Ya
    PROGRESS IN BIOCHEMISTRY AND BIOPHYSICS, 2024, 51 (02) : 345 - 354
  • [48] Detection of circulating tumor cells in non-small cell lung cancer
    Hamilton, Gerhard
    Rath, Barbara
    JOURNAL OF THORACIC DISEASE, 2016, 8 (06)
  • [49] Nanoplatforms for Circulating Tumor Cell Detection in Lung Cancer
    Wikman, Harriet
    Pantel, Klaus
    CLINICAL CHEMISTRY, 2017, 63 (08) : 1318 - 1320
  • [50] Detection of circulating tumor cells in non-small cell lung cancer
    Hanssen, Annkathrin
    Loges, Sonja
    Pantel, Klaus
    Wikman, Harriet
    FRONTIERS IN ONCOLOGY, 2015, 5