The Value of Circulating Tumor Cells and Tumor Markers Detection in Lung Cancer Diagnosis

被引:0
|
作者
Guo, Sumin [1 ]
Chen, Jingyu [2 ]
Hu, Po [3 ]
Li, Chen [3 ]
Wang, Xiang [3 ]
Chen, Ning [4 ]
Sun, Jiale [5 ]
Wang, Yongfeng [3 ]
Wang, Jianling [3 ]
Gu, Weikuan [6 ]
Wu, Shucai [1 ,7 ,8 ,9 ]
机构
[1] Hebei Med Univ, Dept Internal Med, Shijiazhuang, Hebei, Peoples R China
[2] China Acad Chinese Med Sci, Xiyuan Hosp, Dept Chinese Med Internal Med, Beijing, Peoples R China
[3] Hebei Chest Hosp, Lung Canc Prevent & Res Ctr Hebei Prov, Dept Oncol, Shijiazhuang, Hebei, Peoples R China
[4] Hebei Chest Hosp, Lung Canc Prevent & Res Ctr Hebei Prov, Dept Pathol, Shijiazhuang, Hebei, Peoples R China
[5] Hebei North Univ, Coll Lab Med, Zhangjiakou, Hebei, Peoples R China
[6] Univ Tennessee Hlth Sci Ctr, Dept Orthoped Surg & BME Campbell Clin, Memphis, TN USA
[7] Hebei Chest Hosp, Lung Canc Prevent & Res Ctr Hebei Prov, Dept Internal Med, Shijiazhuang, Hebei, Peoples R China
[8] Hebei Med Univ, Dept Internal Med, Shijiazhuang 050017, Hebei, Peoples R China
[9] Hebei Chest Hosp, Lung Canc Prevent & Res Ctr Hebei Prov, Dept Internal Med, Shijiazhuang 050041, Hebei, Peoples R China
关键词
microfluidic chip detection; circulating tumor cells; lung cancer; diagnosis;
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Objective: Circulating tumor cells are complete tumor cells with multi-scale analysis values that present a high potential for lung cancer diagnosis. To enhance the accuracy of lung cancer diagnosis, we detected circulating tumor cells by the innovated conical micro filter integrated microfluidic system. Methods: We recruited 45 subjects of study, including 22 lung cancer patients, 2 precancerous patients, the control group including 14 healthy participants, and 7 patients with lung benign lesions in this prospective study. We calculated the area under the receiver operating characteristic curve of circulating tumor cells, cytokeratin19 fragment, carcinoma embryonic antigen, squamous cell carcinoma, neuron-specific enolase, and their combination, respectively, while compared the circulating tumor cells levels between vein blood and arterial blood. A conical shape filter embedded in a microfluidic chip was used to improve the detection capability of circulating tumor cells. Results: The study indicated that the sensitivity, specificity, positive predictive value, and negative predictive value of circulating tumor cells detection were 81.8%, 90.5%, 90.0%, and 82.6%, respectively. The circulating tumor cells level of lung cancer patient was significantly higher than that of the control group (P < .05). The area under the curve of circulating tumor cells, cytokeratin19 fragment, carcinoma embryonic antigen, squamous cell carcinoma, and neuron-specific enolase alone was 0.838, 0.760, 0.705, 0.614, and 0.636, respectively. The combination area under the curve of the 4 tumor markers (cytokeratin19 fragment, carcinoma embryonic antigen, squamous cell carcinoma, and neuron-specific enolase) was 0.805 less than that of circulating tumor cells alone. Together, the total area under the curve of circulating tumor cell and the 4 tumor markers were 0.847, showing the highest area under the curve value among all biomarkers. In addition, this study found that there was no significant difference in positive rate of circulating tumor cell between arterial and venous blood samples. Conclusion: The circulating tumor cells detection technology by conical micro filter integrated microfluidic could be used for lung cancer diagnosis with high sensitivity and specificity. Complementary combination of circulating tumor cells and conventional 4 lung cancer markers could enhance the clinical application accuracy. Venous blood should be used as a routine sample for circulating tumor cells detections.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Systematic Correlation Analyses of Circulating Tumor Cells with Clinical Variables and Tumor Markers in Lung Cancer Patients
    Wang, Xu
    Ma, Kewei
    Yang, Zhiguang
    Cui, Jiuwei
    He, Hua
    Hoffman, Andrew R.
    Hu, Ji-Fan
    Li, Wei
    JOURNAL OF CANCER, 2017, 8 (15): : 3099 - 3104
  • [22] Circulating tumor cells and circulating tumor DNA in breast cancer diagnosis and monitoring
    Alemzadeh, Effat
    Allahqoli, Leila
    Dehghan, Hamideh
    Mazidimoradi, Afrooz
    Ghasempour, Alireza
    Salehiniya, Hamid
    ONCOLOGY RESEARCH, 2023, 31 (05) : 667 - 675
  • [23] Circulating Tumor Cells in Lung Cancer: Detection Methods and Clinical Applications
    Yu, Na
    Zhou, Jia
    Cui, Fang
    Tang, Xiaokui
    LUNG, 2015, 193 (02) : 157 - 171
  • [24] Detection and Characterization of Circulating Tumor Cells in Lung Cancer: Why and How?
    Hofman, Veronique J.
    Ilie, Marius
    Hofman, Paul M.
    CANCER CYTOPATHOLOGY, 2016, 124 (06) : 380 - 387
  • [25] Circulating Tumor Cells in Lung Cancer: Detection Methods and Clinical Applications
    Na Yu
    Jia Zhou
    Fang Cui
    Xiaokui Tang
    Lung, 2015, 193 : 157 - 171
  • [26] Possible role of circulating tumor cells in early detection of lung cancer
    Poggiana, Cristina
    Rossi, Elisabetta
    Zamarchi, Rita
    JOURNAL OF THORACIC DISEASE, 2020, 12 (07) : 3821 - 3835
  • [27] Simultaneous in situ detection of protein expression of multiple tumor markers of circulating tumor cells and heteroploid of chromosome 8 in primary lung cancer
    Yao, Hanqing
    Wang, Zhengdong
    Yang, Junjun
    Xu, Xingxiang
    Song, Yong
    ANNALS OF TRANSLATIONAL MEDICINE, 2021, 9 (24)
  • [28] Circulating tumor cells as lung cancer biomarkers
    Wong, Maria P.
    JOURNAL OF THORACIC DISEASE, 2012, 4 (06) : 631 - 634
  • [29] Circulating tumor cells in the clinical cancer diagnosis
    Zhang, P.
    Zhou, H.
    Lu, K.
    Wang, Y.
    Feng, T.
    CLINICAL & TRANSLATIONAL ONCOLOGY, 2020, 22 (03): : 279 - 282
  • [30] Circulating tumor cells in the clinical cancer diagnosis
    P. Zhang
    H. Zhou
    K. Lu
    Y. Wang
    T. Feng
    Clinical and Translational Oncology, 2020, 22 : 279 - 282