Performance of Reverse Transcription Loop-Mediated Isothermal Amplification (RT-LAMP) Targeting the RNA Polymerase Gene for the Direct Detection of SARS-CoV2 in Nasopharyngeal Swabs

被引:1
|
作者
Hoffmann, Elias da Rosa [1 ,2 ]
Balzan, Lisiane da Rocha [3 ]
Inamine, Everton [4 ]
Pancotto, Lisiane Rech [4 ]
Gaboardi, Guilherme [5 ]
Cantarelli, Vlademir Vicente [1 ]
机构
[1] Fed Univ Hlth Sci Porto Alegre UFCSPA, Basic Hlth Sci Dept, BR-90050170 Porto Alegre, Brazil
[2] Mol Biol Dept, Bom Pastor Lab, BR-95650000 Igrejinha, Brazil
[3] Diagnost Amer SA, BR-93520340 Novo Hamburgo, Brazil
[4] St Casa de Misericordia Porto Alegre, Cent Lab, BR-90020090 Porto Alegre, Brazil
[5] Serra Gaucha Univ Ctr FSG, Biomed Sci Dept, BR-95020472 Caxias Do Sul, Brazil
关键词
reverse transcriptase-mediated isothermal amplification; LAMP; SARS-CoV-2; coronavirus infections; RP gene; SYSTEM;
D O I
10.3390/ijms241713056
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
In 2020, a global pandemic caused by SARS-CoV-2 was declared. Different institutes proposed diagnostic molecular methods to detect the virus in clinical samples. This study aims to validate and standardize the use of a loop-mediated isothermal amplification (LAMP)-based methodology targeting the viral RP gene, as a faster and low-cost diagnostic method for SARS-CoV-2 infections. The results obtained with RT-LAMP (Reverse Transcriptase) were compared to the results of real-time polymerase chain reaction (RT-PCR) to assess its sensitivity and specificity. In total, 115 samples (nasopharyngeal samples) were used for detecting SARS-CoV-2 by RT-LAMP, with 43 positives and 72 negatives. The study showed a positive predictive value (PPV) of 90.7% and a negative predictive value (VPN) of 100%. The LAMP assay also demonstrated a high sensitivity of 90.7% and a specificity of 100% (confidence interval 77.9-97.4%) when using the lower detection limit of 40 copies/ mu L. The RT-LAMP described here has the potential to detect even the new variants of SARS-CoV-2, suggesting that it may not be significantly affected by gene mutations. The RT-LAMP targeting the RP viral region is faster and less expensive than other molecular approaches, making it an alternative for developing countries.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Multiplex detection of three banana viruses by reverse transcription loop-mediated isothermal amplification (RT-LAMP)
    Jingxin Zhang
    Wayne Borth
    Birun Lin
    Michael Melzer
    Huifang Shen
    Xiaoming Pu
    Dayuan Sun
    Scot Nelson
    John Hu
    Tropical Plant Pathology, 2018, 43 : 543 - 551
  • [22] Clinical testing on SARS-CoV-2 swab samples using reverse-transcription loop-mediated isothermal amplification (RT-LAMP)
    Lai, Meng Yee
    Bukhari, Fatma Diyana Mohd
    Zulkefli, Nur Zulaikha
    Ismail, Ilyiana
    Mustapa, Nur Izati
    Soh, Tuan Suhaila Tuan
    Hassan, Afifah Haji
    Peariasamy, Kalaiarasu M.
    Lee, Yee Leng
    Suppiah, Jeyanthi
    Thayan, Ravindran
    Isa, Mohd Khairi Mat
    Wahid, Nur Zafirah Abdul
    Lau, Yee Ling
    BMC INFECTIOUS DISEASES, 2022, 22 (01)
  • [23] Clinical testing on SARS-CoV-2 swab samples using reverse-transcription loop-mediated isothermal amplification (RT-LAMP)
    Meng Yee Lai
    Fatma Diyana Mohd Bukhari
    Nur Zulaikha Zulkefli
    Ilyiana Ismail
    Nur Izati Mustapa
    Tuan Suhaila Tuan Soh
    Afifah Haji Hassan
    Kalaiarasu M. Peariasamy
    Yee Leng Lee
    Jeyanthi Suppiah
    Ravindran Thayan
    Mohd Khairi Mat Isa
    Nur Zafirah Abdul Wahid
    Yee Ling Lau
    BMC Infectious Diseases, 22
  • [25] Applicability of a colorimetric reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay for SARS-CoV-2 detection in high exposure risk setting
    Nuchnoi, Pornlada
    Piromtong, Pakorn
    Siribal, Saranya
    Anansilp, Korrarit
    Thichanpiang, Peeradech
    Okada, Pilailuk Akkapaiboon
    INTERNATIONAL JOURNAL OF INFECTIOUS DISEASES, 2023, 128 : 285 - 289
  • [26] Analysis of a Reverse Transcription Loop-mediated Isothermal Amplification (RT-LAMP) for yellow fever diagnostic
    Nunes, Marcio R. T.
    Vianez, Joau Lidio, Jr.
    Nunes, Keley N. B.
    da Silva, Sandro Patroca
    Lima, Clayton P. S.
    Guzman, Hilda
    Martins, Livia C.
    Carvalho, Valeria L.
    Tesh, Robert B.
    Vasconcelos, Pedro F. C.
    JOURNAL OF VIROLOGICAL METHODS, 2015, 226 : 40 - 51
  • [27] Rapid detection of HIV-1 by reverse-transcription, loop-mediated isothermal amplification (RT-LAMP)
    Curtis, Kelly A.
    Rudolph, Donna L.
    Owen, S. Michele
    JOURNAL OF VIROLOGICAL METHODS, 2008, 151 (02) : 264 - 270
  • [28] Rapid detection of Akabane virus by a novel reverse transcription loop-mediated isothermal amplification assay (RT-LAMP)
    Jun Qiao
    Junwei Wang
    Qingling Meng
    Guochao Wang
    Yucheng Liu
    Zhihao He
    Haibo Yang
    Zaichao Zhang
    Xuepeng Cai
    Chuangfu Chen
    Virology Journal, 10
  • [29] Rapid and sensitive detection of porcine torovirus by a reverse transcription loop-mediated isothermal amplification assay (RT-LAMP)
    Liu, Xiaowan
    Zhou, Yuancheng
    Yang, Fan
    Liu, Pengjuan
    Cai, Yuhan
    Huang, Jianbo
    Zhu, Ling
    Xu, Zhiwen
    JOURNAL OF VIROLOGICAL METHODS, 2016, 228 : 103 - 107
  • [30] Rapid detection of Akabane virus by a novel reverse transcription loop-mediated isothermal amplification assay (RT-LAMP)
    Qiao, Jun
    Wang, Junwei
    Meng, Qingling
    Wang, Guochao
    Liu, Yucheng
    He, Zhihao
    Yang, Haibo
    Zhang, Zaichao
    Cai, Xuepeng
    Chen, Chuangfu
    VIROLOGY JOURNAL, 2013, 10