Effects of Non-invasive Keratograph Break-Up Time on the Repeatability of Keratometry Measurements

被引:1
|
作者
Shin, Haeeun [1 ]
Jung, Soyeon [1 ]
Jung, Ji Won [1 ,2 ]
机构
[1] Inha Univ, Sch Med, Dept Ophthalmol, Incheon, South Korea
[2] Inha Univ, Sch Med, Dept Ophthalmol, 27 Inhang RO, Incheon 22332, South Korea
来源
关键词
Dry eye syndrome; Keratometry; Keratograph; 5M; Noninvasive keratograph break-up time; INTRAOCULAR-LENS POWER; FILM;
D O I
10.3341/jkos.2023.64.2.99
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the effects of the non-invasive keratograph break-up time on the repeatability of keratometric measure-ments derived using the Keratograph 5M in patients with dry eye syndrome. Methods: Thirty-six patients with dry eye and 30 controls were enrolled. We measured keratometric values twice in all subjects and explored whether the two measurements differed by more than 0.5 diopter (D) (the absolute value). We also evaluated the relationship between the absolute difference and the non-invasive keratograph break-up time (NIKBUT). Results: The intraclass correlation coefficients for astigmatism, flat keratometry (K), steep K, and mean K were all higher than 0.95 in patients, thus lower than in controls. The proportion of eyes with absolute differences over 0.5 D between the two kerato-metric values differed significantly between the dry eye and control groups in terms of the flat K and Kmax values (p = 0.033, 0.037). The average NIKBUT was negatively correlated with the absolute differences in Kmax and astigmatism (p = 0.030, R2 = 0.134 and p = 0.017, R2 = 0.160). Conclusions: In patients with dry eye syndrome, keratometric measurements are reliably repeatable, but slightly less so than in normal controls. The proportions of eyes exhibiting absolute keratometric differences over 0.5 D (two measurements) differed in the dry eye and control groups. The lower the non-invasive keratograph break-up time, the poorer the repeatability of kerato-metric measurements in the dry eye group. Therefore, care is required when obtaining keratometric values for such patients. J Korean Ophthalmol Soc 2023;64(2):99-107
引用
收藏
页码:99 / 107
页数:9
相关论文
共 50 条
  • [31] Modelling non-invasive tear break-up times of soft lenses using a sophisticated in vitroblink platform
    Walther, Hendrik
    Chan, Vivian W. Y.
    Chau-Minh Phan
    Jones, Lyndon William
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [32] Tear break-up time: clinical procedures and their effects
    Cho, P
    Leung, L
    Lam, A
    Choi, A
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 1998, 18 (04) : 319 - 324
  • [33] A novel method of evaluating the non-invasive tear film break-up time and progression of corneal opacification in dogs using imaging video
    Lee, Suk Jun
    Han, Myeong Gyun
    Yang, Su-Jung
    Choi, Yun-Soo
    Kim, Joon Young
    FRONTIERS IN VETERINARY SCIENCE, 2024, 11
  • [34] All-in one automated measurement of ocular surface parameters: interferometry, tear meniscus, non-invasive break-up time and meibography
    Courrier, E.
    Trone, M. C.
    Renault, D.
    Lambert, V.
    Lazreg, S.
    Thuret, G.
    Gain, P.
    ACTA OPHTHALMOLOGICA, 2018, 96 : 25 - 25
  • [35] Location and pattern of non-invasive keratographic tear film break-up according to dry eye disease subtypes
    Kim, Jieun
    Kim, Jung Yong
    Seo, Kyoung Yul
    Kim, Tae-im
    Chin, Hee Seung
    Jung, Ji Won
    ACTA OPHTHALMOLOGICA, 2019, 97 (08) : E1089 - E1097
  • [36] Assessing the relationship between non-invasive tear break-up time and maximum blink interval values among young adults at Mzuzu University
    Mzumara, Thokozani
    Afonne, Joseph
    CLINICAL OPTOMETRY, 2018, 10 : 87 - 91
  • [37] Nichtinvasive Keratographen-Tränenfilmaufreißzeit im Vergleich zur Fluoreszein-TränenfilmaufreißzeitComparison of non-invasive tear film break-up time assessed by keratography with conventional fluorescein tear film break-up time
    Bujar Berisha
    Johannes Nepp
    Dieter Franz Rabensteiner
    Georg Wagner
    Ingrid Boldin
    Haleh Aminfar
    Jutta Horwath-Winter
    Spektrum der Augenheilkunde, 2022, 36 : 139 - 144
  • [38] Analysis of Prosthetic Replacement of the Ocular Surface Ecosystem Anterior Surface Condition Using Noninvasive Keratograph Break-Up Time
    Nodecker, Kayla
    Madabhushi, Sankirth
    Brocks, Daniel
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2024, 50 (01): : 52 - 55
  • [39] Comparison of repeatability of non-invasive and invasive urodynamics
    van Mastrigt, R
    Chung, JWNCHF
    NEUROUROLOGY AND URODYNAMICS, 2004, 23 (04) : 317 - 321
  • [40] Correlation of the thickness of the lipid layer measured by interferometry with the of non-invasive tear break up time
    Garza Leon, Manuel
    Garduno, Fernando
    Salinas, Anna
    Quintanilla, Patricio
    Mendoza, Cesar
    Contreras, Katia
    Rios, Yadira
    Manzano, Marcela
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (07)