Effects of Non-invasive Keratograph Break-Up Time on the Repeatability of Keratometry Measurements

被引:1
|
作者
Shin, Haeeun [1 ]
Jung, Soyeon [1 ]
Jung, Ji Won [1 ,2 ]
机构
[1] Inha Univ, Sch Med, Dept Ophthalmol, Incheon, South Korea
[2] Inha Univ, Sch Med, Dept Ophthalmol, 27 Inhang RO, Incheon 22332, South Korea
来源
关键词
Dry eye syndrome; Keratometry; Keratograph; 5M; Noninvasive keratograph break-up time; INTRAOCULAR-LENS POWER; FILM;
D O I
10.3341/jkos.2023.64.2.99
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the effects of the non-invasive keratograph break-up time on the repeatability of keratometric measure-ments derived using the Keratograph 5M in patients with dry eye syndrome. Methods: Thirty-six patients with dry eye and 30 controls were enrolled. We measured keratometric values twice in all subjects and explored whether the two measurements differed by more than 0.5 diopter (D) (the absolute value). We also evaluated the relationship between the absolute difference and the non-invasive keratograph break-up time (NIKBUT). Results: The intraclass correlation coefficients for astigmatism, flat keratometry (K), steep K, and mean K were all higher than 0.95 in patients, thus lower than in controls. The proportion of eyes with absolute differences over 0.5 D between the two kerato-metric values differed significantly between the dry eye and control groups in terms of the flat K and Kmax values (p = 0.033, 0.037). The average NIKBUT was negatively correlated with the absolute differences in Kmax and astigmatism (p = 0.030, R2 = 0.134 and p = 0.017, R2 = 0.160). Conclusions: In patients with dry eye syndrome, keratometric measurements are reliably repeatable, but slightly less so than in normal controls. The proportions of eyes exhibiting absolute keratometric differences over 0.5 D (two measurements) differed in the dry eye and control groups. The lower the non-invasive keratograph break-up time, the poorer the repeatability of kerato-metric measurements in the dry eye group. Therefore, care is required when obtaining keratometric values for such patients. J Korean Ophthalmol Soc 2023;64(2):99-107
引用
收藏
页码:99 / 107
页数:9
相关论文
共 50 条
  • [1] Repeatability of Non-invasive Keratograph Break-Up Time measurements obtained using Oculus Keratograph 5M
    José Vicente García-Marqués
    Noelia Martínez-Albert
    Cristian Talens-Estarelles
    Santiago García-Lázaro
    Alejandro Cerviño
    International Ophthalmology, 2021, 41 : 2473 - 2483
  • [2] Repeatability of Non-invasive Keratograph Break-Up Time measurements obtained using Oculus Keratograph 5M
    Garcia-Marques, Jose Vicente
    Martinez-Albert, Noelia
    Talens-Estarelles, Cristian
    Garcia-Lazaro, Santiago
    Cervino, Alejandro
    INTERNATIONAL OPHTHALMOLOGY, 2021, 41 (07) : 2473 - 2483
  • [3] Reliability of a New Non-invasive Tear Film Break-up Time Measurement Using a Keratograph
    Jeong, Seongyong
    Lee, Sang Bumm
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2016, 57 (09): : 1354 - 1360
  • [4] Repeatability of non-invasive break-up time measures with a new automated dry eye platform in healthy eyes
    Molina-Martin, Ainhoa
    de Fez, Dolores
    Pinero, David P.
    INTERNATIONAL OPHTHALMOLOGY, 2020, 40 (11) : 2855 - 2864
  • [5] Repeatability of non-invasive break-up time measures with a new automated dry eye platform in healthy eyes
    Ainhoa Molina-Martín
    Dolores de Fez
    David P. Piñero
    International Ophthalmology, 2020, 40 : 2855 - 2864
  • [6] The utility of software-detected non-invasive tear break-up in comparison to fluorescein tear break-up measurements
    Pflugfelder, Stephen C.
    Kikukawa, Yasushi
    Tanaka, Shin
    Kosugi, Takuya
    FRONTIERS IN MEDICINE, 2024, 11
  • [7] The non-invasive tear film break-up time in normal children
    Jones, Sophie M.
    Nischal, Ken K.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2013, 97 (09) : 1129 - 1133
  • [8] Reliability and agreement of subjective and objective non-invasive break-up time measurements in contact lens wearers
    Valencia-Nieto, Laura
    Lopez-de la Rosa, Alberto
    Gonzalez-Garcia, Maria J.
    Lopez-Miguel, Alberto
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2024, 44 (01) : 124 - 130
  • [9] Effects of wearing swimming goggles on non-invasive tear break-up time in a laboratory setting
    Vera, Jesus
    Redondo, Beatriz
    Molina, Ruben
    Jimenez, Raimundo
    JOURNAL OF OPTOMETRY, 2022, 15 (02) : 154 - 159
  • [10] Comparison of non-invasive tear film break-up time assessed by keratography with conventional fluorescein tear film break-up time
    Berisha, Bujar
    Nepp, Johannes
    Rabensteiner, Dieter Franz
    Wagner, Georg
    Boldin, Ingrid
    Aminfar, Haleh
    Horwath-Winter, Jutta
    SPEKTRUM DER AUGENHEILKUNDE, 2022, 36 (06) : 139 - 144