Comprehensive analysis of the influence of magnetic field gradients on single-beam SERF atomic magnetometer

被引:2
|
作者
Li, Jiajie [1 ]
Liu, Ying [1 ,2 ,3 ]
Li, Renjie [1 ]
Cao, Qian [1 ]
Zhou, Tianwei [5 ]
Zhai, Yueyang [1 ,2 ,3 ,4 ]
机构
[1] Beihang Univ, Sch Instrumentat & Optoelect Engn, Key Lab Ultraweak Magnet Field Measurement Technol, Minist Educ, Beijing 100191, Peoples R China
[2] Natl Inst Extremely Weak Magnet Field Infrastructu, Hangzhou 310051, Peoples R China
[3] Beihang Univ, Inst Large scale Sci Facil, Ctr Zero Magnet Field Sci, Beijing 100191, Peoples R China
[4] Natl Lab, Hefei 230088, Peoples R China
[5] Univ Florence, Dept Phys & Astron, I-50019 Sesto Fiorentino, Italy
基金
中国国家自然科学基金;
关键词
Magnetic field gradient; Relaxation rate; Spin polarization; Scale factor; RELAXATION; INHOMOGENEITIES; DIFFUSION;
D O I
10.1016/j.rinp.2023.107231
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Magnetic field gradients interfere with the coherence of the atomic ensemble and degrade the performance of the spin-exchange relaxation-free (SERF) atomic magnetometer. In this paper, the influence of magnetic field gradients is incorporated into the response model of single-beam atomic magnetometer, and the theoretical models of transverse relaxation rate, spin polarization and scale factor are established. Based on this model, we find that magnetic field gradients in different directions can cause varying degrees of degradation in the performance parameters of the magnetometer. The magnetic linewidths under different light power and magnetic field gradients are measured using the designed dedicated magnetic field gradients coils, and the spin polarization and magnetic field gradients relaxation rate are obtained through fitting. An unevenness and deviation of the curve are also observed in the experiments, indicating the presence of the magnetic field gradient of approximately 2 nT/cm in the magnetic shields. Furthermore, in a magnetic field gradient environment of 20 nT/cm, the mean of the long-term sensitivity decreased by 3.5 times and the standard deviation increased by 11 times. It shows that the magnetic field gradients will not only affect the signal-to-noise ratio, but also make the magnetometer more vulnerable to external interference when working. The sensitivity and stability of magnetometer will be greatly reduced. The research in this article provides a theoretical and experimental basis for eliminating the influence of magnetic field gradients and improving the accuracy of magnetic field measurements.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Portable single-beam cesium zero-field magnetometer for magnetocardiography
    Dawson, Rach
    O'Dwyer, Carolyn
    Mrozowski, Marcin S.
    Irwin, Edward
    Mcgilligan, James P.
    Burt, David P.
    Hunter, Dominic
    Ingleby, Stuart
    Rea, Molly
    Holmes, Niall
    Brookes, Matthew J.
    Griffin, Paul. F.
    Riis, Erling
    JOURNAL OF OPTICAL MICROSYSTEMS, 2023, 3 (04):
  • [32] Micro-fabricated SERF Atomic Magnetometer for Weak Gradient Magnetic Field Detection
    Yue, Xiang
    Shang, Jintang
    Ye, Chen
    2019 IEEE 69TH ELECTRONIC COMPONENTS AND TECHNOLOGY CONFERENCE (ECTC), 2019, : 522 - 527
  • [33] Single beam Cs-Ne SERF atomic magnetometer with the laser power differential method
    Chen, Yao
    Zhao, Libo
    Zhang, Ning
    Yu, Mingzhi
    Ma, Yintao
    Han, Xiangguang
    Zhao, Man
    Lin, Qijing
    Yang, Ping
    Jiang, Zhuangde
    OPTICS EXPRESS, 2022, 30 (10) : 16541 - 16552
  • [34] Zero Magnetic Field Calibration for Single-Beam Atomic Magnetometers Using Second Harmonics
    Saenyot, Khanuengchat
    Shoji, Yuya
    Takahashi, Shunya
    Daibo, Masahiro
    IEEE MAGNETICS LETTERS, 2019, 10
  • [35] Triaxial precise magnetic field compensation of a zero-field optically pumped magnetometer based on a single-beam configuration
    Zhang, Shaowen
    Zhang, Kaixuan
    Zhou, Ying
    Ye, Mao
    Lu, Jixi
    OPTICS EXPRESS, 2022, 30 (14): : 24579 - 24588
  • [36] Single-Beam Double-Pass Miniaturized Atomic Magnetometer for Biomagnetic Imaging Systems
    Li, Xiaojie
    Guo, Zhihao
    Yang, Rui
    Feng, Yanying
    IEEE SENSORS JOURNAL, 2023, 23 (12) : 12433 - 12440
  • [37] Single-Beam Room-Temperature Atomic Magnetometer with Large Bandwidth and Dynamic Range
    Kurian, K. K. George
    Sahoo, Sushree S.
    Madhu, P. K.
    Rajalakshmi, G.
    PHYSICAL REVIEW APPLIED, 2023, 19 (05)
  • [38] Comprehensive influence of modulated and bias magnetic fields on an atomic magnetometer
    Yin, Yan
    Zhou, Binquan
    Yin, Kaifeng
    Tang, Junjian
    Ning, Xiaolin
    Han, Bangcheng
    Fang, Jiancheng
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2021, 32 (05)
  • [39] Chip-scale SERF atomic magnetometer without magnetic shield
    Lu, Lin
    Shang, Jintang
    Pan, Zhihua
    Ji, Yu
    2017 IEEE 67TH ELECTRONIC COMPONENTS AND TECHNOLOGY CONFERENCE (ECTC 2017), 2017, : 1900 - 1905
  • [40] The Influence of Spin-Destruction Collisions on The Precision of Atomic SERF Magnetometer
    Liu, Lijun
    Cheng, Shuming
    Xi, Zairong
    Qi, Bo
    2014 33RD CHINESE CONTROL CONFERENCE (CCC), 2014, : 5890 - 5894