共 50 条
Comprehensive analysis of the influence of magnetic field gradients on single-beam SERF atomic magnetometer
被引:2
|作者:
Li, Jiajie
[1
]
Liu, Ying
[1
,2
,3
]
Li, Renjie
[1
]
Cao, Qian
[1
]
Zhou, Tianwei
[5
]
Zhai, Yueyang
[1
,2
,3
,4
]
机构:
[1] Beihang Univ, Sch Instrumentat & Optoelect Engn, Key Lab Ultraweak Magnet Field Measurement Technol, Minist Educ, Beijing 100191, Peoples R China
[2] Natl Inst Extremely Weak Magnet Field Infrastructu, Hangzhou 310051, Peoples R China
[3] Beihang Univ, Inst Large scale Sci Facil, Ctr Zero Magnet Field Sci, Beijing 100191, Peoples R China
[4] Natl Lab, Hefei 230088, Peoples R China
[5] Univ Florence, Dept Phys & Astron, I-50019 Sesto Fiorentino, Italy
基金:
中国国家自然科学基金;
关键词:
Magnetic field gradient;
Relaxation rate;
Spin polarization;
Scale factor;
RELAXATION;
INHOMOGENEITIES;
DIFFUSION;
D O I:
10.1016/j.rinp.2023.107231
中图分类号:
T [工业技术];
学科分类号:
08 ;
摘要:
Magnetic field gradients interfere with the coherence of the atomic ensemble and degrade the performance of the spin-exchange relaxation-free (SERF) atomic magnetometer. In this paper, the influence of magnetic field gradients is incorporated into the response model of single-beam atomic magnetometer, and the theoretical models of transverse relaxation rate, spin polarization and scale factor are established. Based on this model, we find that magnetic field gradients in different directions can cause varying degrees of degradation in the performance parameters of the magnetometer. The magnetic linewidths under different light power and magnetic field gradients are measured using the designed dedicated magnetic field gradients coils, and the spin polarization and magnetic field gradients relaxation rate are obtained through fitting. An unevenness and deviation of the curve are also observed in the experiments, indicating the presence of the magnetic field gradient of approximately 2 nT/cm in the magnetic shields. Furthermore, in a magnetic field gradient environment of 20 nT/cm, the mean of the long-term sensitivity decreased by 3.5 times and the standard deviation increased by 11 times. It shows that the magnetic field gradients will not only affect the signal-to-noise ratio, but also make the magnetometer more vulnerable to external interference when working. The sensitivity and stability of magnetometer will be greatly reduced. The research in this article provides a theoretical and experimental basis for eliminating the influence of magnetic field gradients and improving the accuracy of magnetic field measurements.