Comprehensive analysis of the influence of magnetic field gradients on single-beam SERF atomic magnetometer

被引:2
|
作者
Li, Jiajie [1 ]
Liu, Ying [1 ,2 ,3 ]
Li, Renjie [1 ]
Cao, Qian [1 ]
Zhou, Tianwei [5 ]
Zhai, Yueyang [1 ,2 ,3 ,4 ]
机构
[1] Beihang Univ, Sch Instrumentat & Optoelect Engn, Key Lab Ultraweak Magnet Field Measurement Technol, Minist Educ, Beijing 100191, Peoples R China
[2] Natl Inst Extremely Weak Magnet Field Infrastructu, Hangzhou 310051, Peoples R China
[3] Beihang Univ, Inst Large scale Sci Facil, Ctr Zero Magnet Field Sci, Beijing 100191, Peoples R China
[4] Natl Lab, Hefei 230088, Peoples R China
[5] Univ Florence, Dept Phys & Astron, I-50019 Sesto Fiorentino, Italy
基金
中国国家自然科学基金;
关键词
Magnetic field gradient; Relaxation rate; Spin polarization; Scale factor; RELAXATION; INHOMOGENEITIES; DIFFUSION;
D O I
10.1016/j.rinp.2023.107231
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Magnetic field gradients interfere with the coherence of the atomic ensemble and degrade the performance of the spin-exchange relaxation-free (SERF) atomic magnetometer. In this paper, the influence of magnetic field gradients is incorporated into the response model of single-beam atomic magnetometer, and the theoretical models of transverse relaxation rate, spin polarization and scale factor are established. Based on this model, we find that magnetic field gradients in different directions can cause varying degrees of degradation in the performance parameters of the magnetometer. The magnetic linewidths under different light power and magnetic field gradients are measured using the designed dedicated magnetic field gradients coils, and the spin polarization and magnetic field gradients relaxation rate are obtained through fitting. An unevenness and deviation of the curve are also observed in the experiments, indicating the presence of the magnetic field gradient of approximately 2 nT/cm in the magnetic shields. Furthermore, in a magnetic field gradient environment of 20 nT/cm, the mean of the long-term sensitivity decreased by 3.5 times and the standard deviation increased by 11 times. It shows that the magnetic field gradients will not only affect the signal-to-noise ratio, but also make the magnetometer more vulnerable to external interference when working. The sensitivity and stability of magnetometer will be greatly reduced. The research in this article provides a theoretical and experimental basis for eliminating the influence of magnetic field gradients and improving the accuracy of magnetic field measurements.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Fast In-Situ Triaxial Remanent Magnetic Field Measurement for Single-Beam SERF Atomic Magnetometer Based on Trisection Algorithm
    Long, Tengyue
    Han, Bangcheng
    Song, Xinda
    Suo, Yuchen
    Jia, Le
    PHOTONIC SENSORS, 2023, 13 (03)
  • [2] Fast In-Situ Triaxial Remanent Magnetic Field Measurement for Single-Beam SERF Atomic Magnetometer Based on Trisection Algorithm
    Tengyue Long
    Bangcheng Han
    Xinda Song
    Yuchen Suo
    Le Jia
    Photonic Sensors, 2023, 13
  • [3] Suppression of Optical Frequency Shift Based on Single-Beam Compact SERF Atomic Magnetometer
    Miao, Kexuan
    Hu, Tao
    Guo, Qingqian
    Feng, Xiaoyu
    Zhang, Yin
    Chang, Yan
    Yang, Xiaodong
    CHINESE JOURNAL OF LASERS-ZHONGGUO JIGUANG, 2024, 51 (15): : 15074011 - 15074019
  • [4] Single-Beam Triaxial Atomic Magnetometer Based on Cross Bias Magnetic Field
    Wu Zinan
    Zhang Jialong
    He Mengyang
    Ren Bokang
    Wang Zilong
    Ou Zhonghua
    Yue Huimin
    Zhou Xiaojun
    Liu Yong
    LASER & OPTOELECTRONICS PROGRESS, 2024, 61 (05)
  • [5] Analysis and suppression of magnetic field interference for SERF atomic magnetometer
    Jia, Le
    Li, Jianli
    Song, Xinda
    Qi, Shengjie
    Suo, Yuchen
    Long, Tengyue
    Dai, Yan
    Ning, Xiaolin
    MEASUREMENT, 2024, 227
  • [6] Single-beam three-axis SERF atomic magnetometer based on coordinate system rotation
    Zhang, Jialong
    Chen, Tianpeng
    Wei, Chen
    Ou, Zhonghua
    Yue, Huimin
    Liu, Yong
    OPTICS EXPRESS, 2024, 32 (10): : 17165 - 17172
  • [7] Comprehensive analysis of the magnetic field closed-loop control system in SERF atomic magnetometer
    Jia, Le
    Song, Xinda
    Li, Jianli
    Suo, Yuchen
    Long, Tengyue
    Wu, Zhendong
    Ning, Xiaolin
    SENSORS AND ACTUATORS A-PHYSICAL, 2024, 367
  • [8] The influence of modulated magnetic field on light absorption in SERF atomic magnetometer
    Yin, Yan
    Zhou, Binquan
    Wang, Yaxiang
    Ye, Mao
    Ning, Xiaolin
    Han, Bangcheng
    Fang, Jiancheng
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2022, 93 (01):
  • [9] Interaxial time-domain interference in single-beam SERF magnetometer
    Lin, Shudong
    Yuan, Ziqi
    Tang, Junjian
    Lu, Jixi
    Cao, Qian
    Zhai, Yueyang
    MEASUREMENT, 2023, 215
  • [10] Response signal enhancement for single-beam SERF atomic magnetometer with magneto-optical misalignment phenomenon
    Li, Renjie
    Liu, Ying
    Li, Jiajie
    Cao, Qian
    Huang, Binyue
    Zhai, Yueyang
    OPTICS AND LASER TECHNOLOGY, 2024, 178