Sutureless and Equipment-Free Technique for Contact Lens Viewing System During Vitreoretinal Surgery

被引:1
|
作者
Silpa-Archa, Sukhum [1 ,2 ]
机构
[1] Rangsit Univ, Rajavithi Hosp, Fac Med, Dept Ophthalmol, Bangkok, Thailand
[2] Rajavithi Hosp, Fac Med, Dept Ophthalmol, Bangkok 10400, Thailand
关键词
sutureless vitrectomy; equipment-free; contact lens viewing system; RING-SYSTEM;
D O I
10.1097/IAE.0000000000002933
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose:To report a sutureless and equipment-free technique for contact lens wide-angle viewing system during vitreoretinal surgery.Methods:A step-by-step procedure and a surgical video using this technique were proposed.Results:This technique needs only three-finger control of contact lens either by the left hand (for the right-handed surgeon) or right hand (for the left-handed surgeon). The contact lens is not fixed to the environment (lid speculums, cannulas, corneoscleral limbus); therefore, it allows the surgeon to move and tilt the contact lens freely while keeping a clear view of the retina.Conclusion:The sutureless and equipment-free technique for contact lens viewing system during vitreoretinal surgery has been tried and tested, and it is practical and effective in the real world.
引用
收藏
页码:1204 / 1206
页数:3
相关论文
共 50 条
  • [41] New adjustable arm and magnifying lens for non-contact wide-field viewing system
    Lee, PJ
    Peyman, GA
    Ratnakaram, R
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U91 - U91
  • [42] New type of antidrying lens for vitreous surgery with a noncontact wide-angle viewing system
    Chihara, Tomoyuki
    Kita, Mihori
    CLINICAL OPHTHALMOLOGY, 2013, 7 : 353 - 355
  • [44] The Preliminary Experiences with Three-Dimensional Heads-Up Display Viewing System for Vitreoretinal Surgery under Various Status
    Zhang, Zhaotian
    Wang, Li
    Wei, Yantao
    Fang, Dong
    Fan, Shuxin
    Zhang, Shaochong
    CURRENT EYE RESEARCH, 2019, 44 (01) : 102 - 109
  • [45] A novel drip-irrigative technique for enhanced epiretinal perfluorocarbon liquid clearance during vitreoretinal surgery
    Guo, Jingli
    Gu, Victoria Y.
    Zhou, Yuhan
    Zhao, Peiquan
    Zhao, Dongsheng
    INTERNATIONAL JOURNAL OF RETINA AND VITREOUS, 2024, 10 (01)
  • [46] CONTACT, COAGULATION AND PLATELET INTERACTION WITH HEPARIN TREATED EQUIPMENT DURING HEART-SURGERY
    VANDERKAMP, KWHJ
    VANOEVEREN, W
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1993, 16 (12): : 836 - 842
  • [47] Removal of lens material dropped into the vitreous cavity during cataract surgery using an optical fiber-free intravitreal surgery system
    Horiguchi, M
    Kojima, Y
    Shimada, Y
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (07): : 1256 - 1259
  • [48] A modified-simple technique of removing the lens cortex during cataract surgery
    Han, Kyung Eun
    Han, Se Hoon
    Lim, Dongkwon
    Shin, Min Chul
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2017, 65 (01) : 59 - 61
  • [49] Use of the phaco tip technique for lens cleavage and removal during cataract surgery
    Masuda, Yoichiro
    Oki, Kotaro
    Iwaki, Hisaharu
    Okamoto, Toshinori
    Tsuneoka, Hiroshi
    CLINICAL OPHTHALMOLOGY, 2016, 10 : 1925 - 1929
  • [50] Problems associated with the 25-gauge transconjunctival sutureless vitrectomy system during and after surgery
    Byeon, Suk Ho
    Chu, Young Kwang
    Lee, Sung Chul
    Koh, Hyoung Jun
    Kim, Sung Soo
    Kwon, Oh Woong
    OPHTHALMOLOGICA, 2006, 220 (04) : 259 - 265