Sutureless and Equipment-Free Technique for Contact Lens Viewing System During Vitreoretinal Surgery

被引:1
|
作者
Silpa-Archa, Sukhum [1 ,2 ]
机构
[1] Rangsit Univ, Rajavithi Hosp, Fac Med, Dept Ophthalmol, Bangkok, Thailand
[2] Rajavithi Hosp, Fac Med, Dept Ophthalmol, Bangkok 10400, Thailand
关键词
sutureless vitrectomy; equipment-free; contact lens viewing system; RING-SYSTEM;
D O I
10.1097/IAE.0000000000002933
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose:To report a sutureless and equipment-free technique for contact lens wide-angle viewing system during vitreoretinal surgery.Methods:A step-by-step procedure and a surgical video using this technique were proposed.Results:This technique needs only three-finger control of contact lens either by the left hand (for the right-handed surgeon) or right hand (for the left-handed surgeon). The contact lens is not fixed to the environment (lid speculums, cannulas, corneoscleral limbus); therefore, it allows the surgeon to move and tilt the contact lens freely while keeping a clear view of the retina.Conclusion:The sutureless and equipment-free technique for contact lens viewing system during vitreoretinal surgery has been tried and tested, and it is practical and effective in the real world.
引用
收藏
页码:1204 / 1206
页数:3
相关论文
共 50 条
  • [31] Combining a Contact Lens and Wide-Angle Viewing System for a Wider Fundus View
    Ohji, Masahito
    Tada, Eijiroh
    Futamura, Hideyuki
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2011, 31 (09): : 1958 - 1960
  • [32] A new, non-contact wide field viewing system for vitreous surgery
    Landers, MB
    Peyman, GA
    Wessels, IF
    Whalen, P
    Morales, V
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2003, 136 (01) : 199 - 201
  • [33] Treatment of persistent corneal epithelial defects after vitreoretinal surgery: Autologous serum eye drops or a bandage contact lens?
    Rajabi, Mohammad Taher
    CORNEA, 2008, 27 (09) : 1097 - 1098
  • [34] Combined use of high-reflective index vitrectomy meniscus contact lens and a noncontact wide-angle viewing system in vitreous surgery
    Ohno, Hisato
    CLINICAL OPHTHALMOLOGY, 2011, 5 : 1109 - 1111
  • [35] Combining Magnifying Prismatic Lens With Wide-Angle Viewing System to Enhance View of Peripheral Retina During Vitreous Surgery
    Ohtsuki, Masanori
    Inoue, Makoto
    Uda, Shigekazu
    Tada, Eijiroh
    Hirakata, Akito
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2012, 32 (09): : 1983 - 1987
  • [36] Combined vitrectomy lens and contact electrode for ERG recording during surgery
    Montezuma, SR
    Rizzo, JF
    Ziv, OR
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2002, 22 (06): : 828 - 829
  • [37] Commercially available rigid gas-permeable contact lens for protecting the cornea from drying during vitrectomy with a wide viewing system
    Kamei, Motohiro
    Matsumura, Nagakazu
    Sakaguchi, Hirokazu
    Oshima, Yusuke
    Ikuno, Yasushi
    Nishida, Kohji
    CLINICAL OPHTHALMOLOGY, 2012, 6 : 1321 - 1324
  • [38] New modified iris suture technique for pupillary dilation in aphakic eyes during vitreoretinal surgery
    Han, Feng-Mei
    Han, Quan-Hong
    Chu, Yan-Hua
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2010, 3 (04) : 356 - 357
  • [39] A new, non-contact wide-field viewing system for vitreous surgery
    Hawkins, WR
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2003, 136 (06) : 1191 - 1192
  • [40] Evaluation of single use disposable miniaturized high-resolution wide-field contact lens for vitreoretinal surgery.
    Ahmed, Harris
    Subramanian, Sam
    Chalam, Kakarla
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)