Force-Controlled Biomechanical Simulation of Orthodontic Tooth Movement with Torque Archwires Using HOSEA (Hexapod for Orthodontic Simulation, Evaluation and Analysis)

被引:3
|
作者
Haas, Ellen [1 ]
Schmid, Andreas [1 ]
Stocker, Thomas [1 ]
Wichelhaus, Andrea [1 ]
Sabbagh, Hisham [1 ]
机构
[1] Ludwig Maximilians Univ Munchen, LMU Univ Hosp, Dept Orthodont & Dentofacial Orthoped, Goethestr 70, D-80336 Munich, Germany
来源
BIOENGINEERING-BASEL | 2023年 / 10卷 / 09期
关键词
orthodontics; 3D measurement; force control; biomechanics; hexapod;
D O I
10.3390/bioengineering10091055
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
This study aimed to investigate the dynamic behavior of different torque archwires for fixed orthodontic treatment using an automated, force-controlled biomechanical simulation system. A novel biomechanical simulation system (HOSEA) was used to simulate dynamic tooth movements and measure torque expression of four different archwire groups: 0.017 '' x 0.025 '' torque segmented archwires (TSA) with 30 degrees torque bending, 0.018 '' x 0.025 '' TSA with 45 degrees torque bending, 0.017 '' x 0.025 '' stainless steel (SS) archwires with 30 degrees torque bending and 0.018 '' x 0.025 '' SS with 30 degrees torque bending (n = 10/group) used with 0.022 '' self-ligating brackets. The Kruskal-Wallis test was used for statistical analysis (p < 0.050). The 0.018 '' x 0.025 '' SS archwires produced the highest initial rotational torque moment (M-y) of -9.835 Nmm. The reduction in rotational moment per degree (M-y/R-y) was significantly lower for TSA compared to SS archwires (p < 0.001). TSA 0.018 '' x 0.025 '' was the only group in which all archwires induced a min. 10 degrees rotation in the simulation. Collateral forces and moments, especially F-x, F-z and M-x, occurred during torque application. The measured forces and moments were within a suitable range for the application of palatal root torque to incisors for the 0.018 '' x 0.025 '' archwires. The 0.018 '' x 0.025 '' TSA reliably achieved at least 10 degrees incisal rotation without reactivation.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Early tooth movement pattern after application of a controlled continuous orthodontic force. A human experimental model
    Lundgren, D
    OwmanMoll, P
    Kurol, J
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1996, 110 (03) : 287 - 295
  • [22] Numeric simulation model for long-term orthodontic tooth movement with contact boundary conditions using the finite element method
    Hamanaka, Ryo
    Yamaoka, Satoshi
    Tuan Nguyen Anh
    Tominaga, Jun-ya
    Koga, Yoshiyuki
    Yoshida, Noriaki
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2017, 152 (05) : 601 - 612
  • [23] A new system for 3D planning of orthodontic treatment and 3D tooth movement simulation
    Alcañiz, M
    Chinesta, F
    Albalat, S
    Grau, V
    Monserrat, C
    COMPUTER METHODS IN BIOMECHANICS & BIOMEDICAL ENGINEERING - 2, 1998, : 645 - 654
  • [24] Computer simulation of orthodontic tooth movement using CT image-based voxel finite element models with the level set method
    Hasegawa, Masakazu
    Adachi, Taiji
    Takano-Yamamoto, Teruko
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2016, 19 (05) : 474 - 483
  • [25] In Vitro Investigation Using a New Biomechanical Force-Torque Analysis System: Comparison of Conventional and CAD/CAM-Fixed Orthodontic Retainers
    Thaden, Francesca
    Hoetzel, Linus
    Sabbagh, Hisham
    Mertmann, Matthias
    Wichelhaus, Andrea
    MATERIALS, 2024, 17 (19)
  • [26] Simulation of orthodontic force of archwire applied to full dentition using virtual bracket displacement method
    Zhou, Xinwen
    Gan, Yangzhou
    Zhao, Qunfei
    Xiong, Jing
    Xia, Zeyang
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2019, 35 (05)
  • [27] Precision Orthodontic Force Simulation Using Nodal Displacement-Based Archwire Loading Approach
    Ahmad, Waheed
    Liang, Kanhui
    Xiong, Jing
    Dai, Juan
    Cao, Jun
    Xia, Zeyang
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2024, 40 (12)
  • [28] Interleukin-1β levels, pain intensity, and tooth movement using two different magnitudes of continuous orthodontic force
    Luppanapornlarp, Suwannee
    Kajii, Takashi S.
    Surarit, Rudee
    Iida, Junichiro
    EUROPEAN JOURNAL OF ORTHODONTICS, 2010, 32 (05) : 596 - 601
  • [29] Effectiveness of using a vibrating device in accelerating orthodontic tooth movement: A systematic review and meta-analysis
    Abd Elmotaleb, Mohamed Atfy
    Elnamrawy, Manal M.
    Sharaby, Foud
    Elbeialy, Amr R.
    ElDakroury, Amr
    JOURNAL OF INTERNATIONAL SOCIETY OF PREVENTIVE AND COMMUNITY DENTISTRY, 2019, 9 (01): : 5 - 12
  • [30] Evaluation of exaggerated claims in the abstracts of systematic reviews reporting accelerated orthodontic tooth movement: a meta research analysis
    Shyagali, Tarulatha R.
    Rathore, Ayesha
    Kapoor, Shanya
    Gupta, Abhishek
    Tiwari, Anil
    Patidar, Rahul
    AUSTRALASIAN ORTHODONTIC JOURNAL, 2022, 38 (02): : 268 - 277