Simulation of orthodontic force of archwire applied to full dentition using virtual bracket displacement method

被引:11
|
作者
Zhou, Xinwen [1 ]
Gan, Yangzhou [2 ,3 ]
Zhao, Qunfei [1 ]
Xiong, Jing [2 ]
Xia, Zeyang [2 ,3 ]
机构
[1] Shanghai Jiao Tong Univ, Dept Automat, Shanghai 200240, Peoples R China
[2] Chinese Acad Sci, Shenzhen Inst Adv Technol, 1068 Xueyuan Ave, Shenzhen 518055, Peoples R China
[3] Shenzhen Inst Adv Technol, CAS Key Lab Human Machine Intelligence Synergy Sy, Shenzhen 518055, Peoples R China
基金
中国国家自然科学基金;
关键词
appliance loading; continuous archwire; finite element method; full dentition; orthodontic force; virtual bracket; FINITE-ELEMENT-ANALYSIS; NUMERICAL-SIMULATION; MAXILLARY ARCH; FORCE/COUPLE SYSTEMS; TOOTH MOVEMENT; PERIODONTAL-LIGAMENT; STRESS-DISTRIBUTION; SPACE CLOSURE; CANINE; ALIGNMENT;
D O I
10.1002/cnm.3189
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
ObjectiveOrthodontic force simulation of tooth provides important guidance for clinical orthodontic treatment. However, previous studies did not involve the simulation of orthodontic force of archwire applied to full dentition. This study aimed to develop a method to simulate orthodontic force of tooth produced by loading a continuous archwire to full dentition using finite element method. MethodA three-dimensional tooth-periodontal ligament-bone complex model of mandible was reconstructed from computed tomography images, and models of brackets and archwire were built. The simulation was completed through two steps. First, node displacements of archwire before and after loading were estimated through moving virtual brackets to drive archwire deformation. Second, the obtained node displacements were loaded to implement the loading of archwire, and orthodontic force was calculated. An orthodontic force tester (OFT) was used to measure orthodontic force in vitro for the validation. ResultsAfter the simulation convergence, archwire was successfully loaded to brackets, and orthodontic force of teeth was obtained. Compared with the measured orthodontic force using the OFT, the absolute difference of the simulation results ranged from 0.5 to 22.7cN for force component and ranged from 2.2 to 80.0cN center dot mm for moment component, respectively. The relative difference of the simulation results ranged from 2.5% to 11.0% for force component, and ranged from 0.6% to 14.7% for moment component, respectively. ConclusionsThe developed orthodontic force simulation method based on virtual bracket displacement can be used to simulate orthodontic force provided by the archwire applied to full dentition.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Precision Orthodontic Force Simulation Using Nodal Displacement-Based Archwire Loading Approach
    Ahmad, Waheed
    Liang, Kanhui
    Xiong, Jing
    Dai, Juan
    Cao, Jun
    Xia, Zeyang
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2024, 40 (12)
  • [2] Modeling and Experimental Study of Friction Force between Orthodontic Archwire and Bracket
    Jiang, Jingang
    Wu, Dianhao
    Wang, Lei
    Zhang, Yongde
    Liu, Yi
    Yao, Liang
    Mocaxue Xuebao/Tribology, 2022, 42 (03): : 520 - 531
  • [3] The comparison of the frictional force by the type and angle of orthodontic bracket and the coated or non-coated feature of archwire
    Jang, Tae-Ho
    Kim, Sang-Cheol
    Cho, Jin-Hyoung
    Chae, Jong-Moon
    Chang, Na-Young
    Kang, Kyung Hwa
    KOREAN JOURNAL OF ORTHODONTICS, 2011, 41 (06): : 399 - 410
  • [4] Orthodontic Force Simulation of Tooth-PDL-Bone Complex under Archwire Loading
    Zhou, Xinwen
    Xia, Zeyang
    Gan, Yangzhou
    Zhang, Dongxia
    Xiong, Jing
    Fang, Peng
    Li, Guanglin
    Zhao, Qunfei
    2016 38TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2016, : 6030 - 6033
  • [5] Orthodontic simulation system with force feedback for training complete bracket placement procedures
    Ye F.
    Liu L.
    Yan B.
    Zhao X.
    Hao A.
    Virtual Reality and Intelligent Hardware, 2021, 3 (04): : 261 - 273
  • [6] Orthodontic simulation system with force feedback for training complete bracket placement procedures
    Fan YE
    Luwei LIU
    Bin YAN
    Xiaohan ZHAO
    Aimin HAO
    虚拟现实与智能硬件(中英文), 2021, 3 (04) : 261 - 273
  • [7] Development of Regression Models for the Prediction of NiTi Archwire Forces in an Orthodontic Bracket System Using Response Surface Methodology
    Seman, Sareh Aiman Hilmi Abu
    Ng, Ching Wei
    Razali, Muhammad Fauzinizam
    Mahmud, Abdus Samad
    PERTANIKA JOURNAL OF SCIENCE AND TECHNOLOGY, 2022, 30 (04): : 2377 - 2391
  • [8] Validation and reliability of a prototype orthodontic bracket debonding device equipped with force-sensitive resistor (FSR): a novel method of measuring orthodontic bracket debonding force in vivo
    Tamzid Ahmed
    Norma Ab Rahman
    Mohammad Khursheed Alam
    Progress in Orthodontics, 20
  • [9] Validation and reliability of a prototype orthodontic bracket debonding device equipped with force-sensitive resistor (FSR): a novel method of measuring orthodontic bracket debonding force in vivo
    Ahmed, Tamzid
    Ab Rahman, Norma
    Alam, Mohammad Khursheed
    PROGRESS IN ORTHODONTICS, 2019, 20 (1)
  • [10] VIRTUAL-DISPLACEMENT PRINCIPLE APPLIED TO FORCE-MULTIPLYING DEVICES
    CHALENKO, NS
    MEASUREMENT TECHNIQUES USSR, 1984, 27 (10): : 923 - 925