Version 8 IMK/IAA MIPAS measurements of CFC-11, CFC-12, and HCFC-22

被引:0
|
作者
Stiller, Gabriele P. [1 ]
von Clarmann, Thomas [1 ]
Glatthor, Norbert [1 ]
Grabowski, Udo [1 ]
Kellmann, Sylvia [1 ]
Kiefer, Michael [1 ]
Laeng, Alexandra [1 ]
Linden, Andrea [1 ]
Funke, Bernd [2 ]
Garcia-Comas, Maya [2 ]
Lopez-Puertas, Manuel [2 ]
机构
[1] Karlsruhe Inst Technol, Inst Meteorol & Climate Res, Karlsruhe, Germany
[2] CSIC, Inst Astrofis Andalucia, Granada, Spain
关键词
ABSORPTION CROSS-SECTIONS; LIMB EMISSION-SPECTRA; ATMOSPHERIC SOUNDING MIPAS; IN-SITU MEASUREMENTS; LIVED TRACE GASES; LEVEL; PROCESSOR; LOWER STRATOSPHERE; MICHELSON INTERFEROMETER; CCL2F2; MEASUREMENTS; INTEGRAL EQUATIONS;
D O I
10.5194/amt-17-1759-2024
中图分类号
P4 [大气科学(气象学)];
学科分类号
0706 ; 070601 ;
摘要
The Michelson Interferometer for Passive Atmospheric Sounding (MIPAS) on Envisat provided infrared limb emission spectra, which were used to infer global distributions of CFC-11, CFC-12, and HCFC-22. Spectra were analysed using constrained non-linear least-squares fitting. Changes with respect to earlier data versions refer to the use of version 8 spectra, the altitude range where the background continuum is considered, details of the regularization and microwindow selection, and the occasional joint fitting of interfering species, the use of new spectroscopic data, the joint fit of a tangent-height-dependent spectral offset, and the use of 2D temperature fields. In the lower stratosphere the error budget is dominated by uncertainties in spectroscopic data, while above this measurement noise is the leading error source. The vertical resolution of CFC-11 and CFC-12 is 2-3 km near the tropopause, about 4 km at 30 km altitude, and 6-10 km at 50 km . The vertical resolution of HCFC-22 is somewhat coarser, 3-4 km at the tropopause and 10-12 km at 35 km altitude. In the altitude range of interest, the horizontal resolution is typically limited by the horizontal sampling of the measurements, not by the smearing of the retrievals. Horizontal information displacement does not exceed 150 km , which can become an issue only for comparisons with model simulations with high horizontal resolution or localized in situ observations. Along with the regular data product, an alternative representation of the data on a coarser vertical grid is offered. These data can be used without consideration of the averaging kernels. The new data version provides improvement with respect to reduction of biases and improved consistency between the full- and reduced-resolution mission period of MIPAS.
引用
收藏
页码:1759 / 1789
页数:31
相关论文
共 50 条
  • [11] DUPONT PLANT QUITS PRODUCING CFC-11, CFC-12
    不详
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1995, 37 (08): : 16 - 16
  • [12] Retrieval of CFC-11 and CFC-12 from Envisat MIPAS observations by means of rapid radiative transfer calculations
    Hoffmann, L
    Spang, R
    Kaufmann, M
    Riese, M
    ATMOSPHERIC REMOTE SENSING: EARTH'S SURFACE, TROPOSPHERE, STRATOSPHERE AND MESOSPHERE - I, 2005, 36 (05): : 915 - 921
  • [13] Estimating emissions of HCFC-22 and CFC-11 in China by atmospheric observations and inverse modeling
    XingQin An
    Stephan Henne
    Bo Yao
    Martin K. Vollmer
    LingXi Zhou
    Yan Li
    Science China Chemistry, 2012, 55 : 2233 - 2241
  • [14] CONSUMPTION OF FREONS CFC-11 AND CFC-12 BY ANAEROBIC SEDIMENTS AND SOILS
    LOVLEY, DR
    WOODWARD, JC
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1992, 26 (05) : 925 - 929
  • [15] A REEXAMINATION OF THE GREENHOUSE-EFFECT DUE TO CFC-11 AND CFC-12
    KRATZ, DP
    VARANASI, P
    JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 1992, 48 (03): : 245 - 254
  • [16] Estimating emissions of HCFC-22 and CFC-11 in China by atmospheric observations and inverse modeling
    HENNE Stephan
    VOLLMER Martin K
    Science China(Chemistry), 2012, 55 (10) : 2233 - 2241
  • [17] Estimating emissions of HCFC-22 and CFC-11 in China by atmospheric observations and inverse modeling
    HENNE Stephan
    VOLLMER Martin K
    Science China(Chemistry), 2012, (10) : 2233 - 2241
  • [18] Estimating emissions of HCFC-22 and CFC-11 in China by atmospheric observations and inverse modeling
    An XingQin
    Henne, Stephan
    Yao Bo
    Vollmer, Martin K.
    Zhou LingXi
    Li Yan
    SCIENCE CHINA-CHEMISTRY, 2012, 55 (10) : 2233 - 2241
  • [19] 制冷系统中CFC-12的替代物-HCFC-22
    陈玖伟
    浙江水产学院学报, 1990, 9 (01) : 57 - 61
  • [20] Releases of refrigerant gases (CFC-12, HCFC-22 and HFC-134a) to the atmosphere
    McCulloch, A
    Midgley, PM
    Ashford, P
    ATMOSPHERIC ENVIRONMENT, 2003, 37 (07) : 889 - 902