Releases of refrigerant gases (CFC-12, HCFC-22 and HFC-134a) to the atmosphere

被引:118
|
作者
McCulloch, A
Midgley, PM
Ashford, P
机构
[1] Univ Bristol, Sch Chem, Bristol BS8 1TS, Avon, England
[2] M&D Consulting, D-70771 Leinfelden Musberg, Germany
[3] Caleb Management Serv, Almondsbury BS32 4JT, England
关键词
dichlorodifluoromethane; chlorodifluoromethane; tetrafluoroethane; Montreal Protocol; atmospheric concentration; atmospheric lifetime;
D O I
10.1016/S1352-2310(02)00975-5
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Two of the gases, CFC-12 (dichlorodifluoromethane, CF2Cl2)and HCFC-22 (chlorodifluoromethane, CHCIF2) have long histories of emission from refrigeration and other uses. Production and sales records show the expected fall in the amounts of CFC-12 used in refrigeration after the Montreal Protocol came into effect but this does not seem to have been accompanied by significant substitution by HCFC-22, demand for which appears governed by organic growth. HFC-134a (1.1,1,2-tetrafluoroethane, CH2FCF3) is a relative newcomer that has partially substituted for CFC-12. After developing a single data set for the global use of each substance in refrigeration, foam blowing and aerosol propulsion. and other promptly emissive uses, annual releases of the compounds were estimated by applying emission functions derived from surveying both the producers of the chemicals and the principal industrial users. For CFC-12 and HFC-134a. atmospheric concentrations calculated from the emissions estimated here are in good agreement with observations, verifying that the emission functions adequately describe the relationship between the quantities in use, the atmospheric lifetimes of 100 and 14.6 years, respectively, and the extent of release into the atmosphere. The agreement between observation and calculation is poorer for HCFC-22, if its atmospheric lifetime is 12 years, but becomes much closer with a lifetime of 10 years. An 80% reduction in CFC requirement has been substituted only to the extent of 25% by HFC-134a. This is consistent with improved technology to curtail leakage and so enable lower system charges that, in turn, translate into less demand. For the same reason, the refrigeration emission function for HFC-134a over the period 1990-2000 was not significantly different from that of CFC-12. The lower absolute rate of leakage and lower absolute charge sizes combining to maintain a similar relative rate of loss.,(C) 2003 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:889 / 902
页数:14
相关论文
共 50 条
  • [1] HCFC-22 AS A REPLACEMENT FOR CFC-12
    SULEIMAN, YM
    SAID, SAM
    ISMAIL, B
    [J]. APPLIED ENERGY, 1994, 49 (01) : 1 - 8
  • [2] COMPARISON OF THE REFRIGERANTS HFC-134A AND CFC-12
    PETERSSON, B
    THORSELL, H
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1990, 13 (03): : 176 - 180
  • [3] Emissions of the refrigerants HFC-134a, HCFC-22, and CFC-12 from road traffic: Results from a tunnel study (Gubrist Tunnel, Switzerland)
    Stemmler, K
    O'Doherty, S
    Buchmann, B
    Reimann, S
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2004, 38 (07) : 1998 - 2004
  • [4] HFC 134A AS A SUBSTITUTE REFRIGERANT FOR CFC-12
    SPAUSCHUS, HO
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1988, 11 (06): : 389 - 392
  • [5] THERMODYNAMIC ANALYSES OF THE CFC-12 AND HFC-134A REFRIGERATION CYCLES
    KHAN, SH
    ZUBAIR, SM
    [J]. ENERGY, 1993, 18 (07) : 717 - 726
  • [6] Evaluation of capillary tube performance for CFC-12 and HFC-134A
    Wong, TN
    Ooi, KT
    [J]. INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 1996, 23 (07) : 993 - 1001
  • [7] HCFC-22/HFC-152a混合工质替代冰箱CFC-12的应用
    邱桂民
    [J]. 精细与专用化学品, 1999, (22) : 57 - 57
  • [8] Global emissions of refrigerants HCFC-22 and HFC-134a: Unforeseen seasonal contributions
    Xiang, Bin
    Patra, Prabir K.
    Montzka, Stephen A.
    Miller, Scot M.
    Elkins, James W.
    Moore, Fred L.
    Atlas, Elliot L.
    Miller, Ben R.
    Weiss, Ray F.
    Prinn, Ronald G.
    Wofsy, Steven C.
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2014, 111 (49) : 17379 - 17384
  • [9] Thermodynamic analyses of the CFC-12 and HFC-134A refrigeration cycles - Response
    Zubair, SM
    [J]. ENERGY, 1996, 21 (06) : 519 - 519
  • [10] NAVY INVESTIGATIONS OF HFC-134A AS A REPLACEMENT FOR CFC-12 IN SHIPBOARD APPLICATIONS
    WYLIE, JD
    NICKENS, AD
    BRUNNER, GP
    HAMILTON, DL
    [J]. NAVAL ENGINEERS JOURNAL, 1992, 104 (04) : 93 - 94