A Fiber-Optical Dosimetry Sensor for Gamma-Ray Irradiation Measurement in Biological Applications

被引:1
|
作者
Elsharkawi, Adel Shaaban Awad [1 ,2 ]
Alazab, Huda A. [3 ]
Sayed, Mahmoud [1 ]
Askar, Mostafa A. [4 ]
Abdelrahman, Ibrahim Y. [4 ]
Arafa, Amany A. [1 ]
Saleh, Hassan I. [1 ]
Gomaa, Lotfy R. [5 ]
Du, Yi-Chun [6 ,7 ]
机构
[1] Egyptian Atom Energy Author EAEA, Natl Ctr Radiat Res & Technol NCRRT, Dept Radiat Engn, Cairo 11787, Egypt
[2] Natl Cheng Kung Univ, Adv Optoelect Technol Ctr, Tainan 70101, Taiwan
[3] Egyptian Atom Energy Author, Nucl & Radiol Safety Res Ctr, Cairo, Egypt
[4] Egyptian Atom Energy Author EAEA, Natl Ctr Radiat Res & Technol NCRRT, Radiat Biol Dept, Cairo 11787, Egypt
[5] Banha Univ, Fac Engn Shoubra, Cairo 11672, Egypt
[6] Natl Cheng Kung Univ, Dept Biomed Engn, Tainan 70101, Taiwan
[7] Natl Cheng Kung Univ, Med Device Innovat Ctr, Tainan 70101, Taiwan
来源
BIOSENSORS-BASEL | 2023年 / 13卷 / 12期
关键词
fiber-optical dosimeter (FOD); two-dimensional distribution; in vivo animal models; thermo-luminescence detector; SIO2; OPTICAL-FIBERS; RADIATION-INDUCED ATTENUATION; THERMOLUMINESCENCE RESPONSE; HIGH-ENERGY; PHOTON;
D O I
10.3390/bios13121010
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this paper, we propose a novel fiber-optical dosimetry sensor for radiation measurement in biological applications. A two-dimensional (2D) fiber-optical dosimeter (FOD) for radiation measurement is considered. The sensors are arranged as a 2D array in a tailored holder. This FOD targets accurate industrial and medical applications which seek more tolerant radiation dosimeters. In this paper, the FOD sensors are subjected to gamma-ray radiation facilities from the 137Cs gamma-ray irradiator type for low doses and 60Co gamma-ray irradiator for high doses. For better evaluation of radiation effects on the FOD sample, the measurements are performed using eight sensors (hollow cylinder shape) with two samples in each dose. The sensors were measured before and after each irradiation. To the author's knowledge, the measurements of FOD transplanted inside animals are presented for the first time in this paper. A 2D simulation program has been implemented for numerical simulation based on the attenuation factors from the absorbed dose inside the in vivo models. A comparison between the FOD and the standard thermo-luminescence detector is presented based on the test of in vivo animal models. The results indicate that the proposed FOD sensor is more stable and has higher sensitivity.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] Fiber-optical sensor for measuring concentration of solution
    2005, North China Institute of Technology, Taiyun, China (26):
  • [32] Development of a Field Emission Image Sensor Tolerant to Gamma-Ray Irradiation
    Gotoh, Yasuhito
    Tsuji, Hiroshi
    Nagao, Masayoshi
    Masuzawa, Tomoaki
    Neo, Yoichiro
    Mimura, Hidenori
    Okamoto, Tamotsu
    Igari, Tomoya
    Akiyoshi, Masafumi
    Sato, Nobuhiro
    Takagi, Ikuji
    IEEE TRANSACTIONS ON ELECTRON DEVICES, 2020, 67 (04) : 1660 - 1665
  • [33] Precision digital accelerometer with fiber-optical sensor
    Demyanenko, PA
    Zinkovskii, YF
    Prokofev, MI
    IZVESTIYA VYSSHIKH UCHEBNYKH ZAVEDENII RADIOELEKTRONIKA, 1997, 40 (1-2): : 39 - 47
  • [34] FIBER-OPTICAL SENSOR OF SPATIAL COHERENCE OF LIGHT
    BARANOV, DV
    BELOVOLOV, MI
    JURILOVA, IV
    ISAEV, SK
    KRYUKOV, AP
    KUZNETSOV, AV
    VESTNIK MOSKOVSKOGO UNIVERSITETA SERIYA 3 FIZIKA ASTRONOMIYA, 1989, 30 (04): : 61 - 64
  • [35] Modeling of the fiber-optical water salinity sensor
    Khotiaintsev, S.
    Khotiaintsev, K.
    Garcia-Moreno, A.
    LFNM 2006: 8TH INTERNATIONAL CONFERENCE ON LASER AND FIBER-OPTICAL NETWORKS MODELING, PROCEEDINGS, 2006, : 36 - +
  • [36] Dosimetry Equivalence Between X-Ray and Gamma-Ray Irradiation with Validated Monte Carlo Simulations
    Rodriguez, J.
    Peter, R.
    Yang, J.
    Serrano, J.
    Nostrand, C.
    Steri, V.
    Gunther, C.
    Seo, Y.
    MEDICAL PHYSICS, 2022, 49 (06) : E977 - E977
  • [37] SOME COMMENTS ON GAMMA-RAY IMPLANT DOSIMETRY
    KIM, YS
    RADIOLOGY, 1976, 120 (02) : 413 - 416
  • [38] A NEW PHOTOGRAPHIC MATERIAL FOR GAMMA-RAY DOSIMETRY
    WHIPPLE, HO
    HORNBERGER, CS
    HOFFMAN, JG
    NOLAN, JF
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1948, 60 (02) : 175 - 181
  • [39] MIXED RECOIL PROTON AND GAMMA-RAY DOSIMETRY
    HART, EJ
    RADIATION RESEARCH, 1958, 9 (01) : 127 - 127
  • [40] Optical fiber sensor for low dose gamma irradiation monitoring
    de Andres, Ana I.
    Esteban, Oscar
    Embid, Miguel
    SIXTH EUROPEAN WORKSHOP ON OPTICAL FIBRE SENSORS, 2016, 9916