A Fiber-Optical Dosimetry Sensor for Gamma-Ray Irradiation Measurement in Biological Applications

被引:1
|
作者
Elsharkawi, Adel Shaaban Awad [1 ,2 ]
Alazab, Huda A. [3 ]
Sayed, Mahmoud [1 ]
Askar, Mostafa A. [4 ]
Abdelrahman, Ibrahim Y. [4 ]
Arafa, Amany A. [1 ]
Saleh, Hassan I. [1 ]
Gomaa, Lotfy R. [5 ]
Du, Yi-Chun [6 ,7 ]
机构
[1] Egyptian Atom Energy Author EAEA, Natl Ctr Radiat Res & Technol NCRRT, Dept Radiat Engn, Cairo 11787, Egypt
[2] Natl Cheng Kung Univ, Adv Optoelect Technol Ctr, Tainan 70101, Taiwan
[3] Egyptian Atom Energy Author, Nucl & Radiol Safety Res Ctr, Cairo, Egypt
[4] Egyptian Atom Energy Author EAEA, Natl Ctr Radiat Res & Technol NCRRT, Radiat Biol Dept, Cairo 11787, Egypt
[5] Banha Univ, Fac Engn Shoubra, Cairo 11672, Egypt
[6] Natl Cheng Kung Univ, Dept Biomed Engn, Tainan 70101, Taiwan
[7] Natl Cheng Kung Univ, Med Device Innovat Ctr, Tainan 70101, Taiwan
来源
BIOSENSORS-BASEL | 2023年 / 13卷 / 12期
关键词
fiber-optical dosimeter (FOD); two-dimensional distribution; in vivo animal models; thermo-luminescence detector; SIO2; OPTICAL-FIBERS; RADIATION-INDUCED ATTENUATION; THERMOLUMINESCENCE RESPONSE; HIGH-ENERGY; PHOTON;
D O I
10.3390/bios13121010
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this paper, we propose a novel fiber-optical dosimetry sensor for radiation measurement in biological applications. A two-dimensional (2D) fiber-optical dosimeter (FOD) for radiation measurement is considered. The sensors are arranged as a 2D array in a tailored holder. This FOD targets accurate industrial and medical applications which seek more tolerant radiation dosimeters. In this paper, the FOD sensors are subjected to gamma-ray radiation facilities from the 137Cs gamma-ray irradiator type for low doses and 60Co gamma-ray irradiator for high doses. For better evaluation of radiation effects on the FOD sample, the measurements are performed using eight sensors (hollow cylinder shape) with two samples in each dose. The sensors were measured before and after each irradiation. To the author's knowledge, the measurements of FOD transplanted inside animals are presented for the first time in this paper. A 2D simulation program has been implemented for numerical simulation based on the attenuation factors from the absorbed dose inside the in vivo models. A comparison between the FOD and the standard thermo-luminescence detector is presented based on the test of in vivo animal models. The results indicate that the proposed FOD sensor is more stable and has higher sensitivity.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Effect of Temperature and Gamma-Ray Irradiation on Optical Characteristics of Fiber Bragg Grating Inscribed Radiation-Resistant Optical Fiber
    Seongmin Ju
    Youngwoong Kim
    Kadathala Linganna
    Yune Hyoun Kim
    Won-Taek Han
    Photonic Sensors, 2020, 10 : 16 - 33
  • [22] The effect of gamma-ray irradiation on bulk optical plastic materials
    Prajzler, Vaclav
    Chlupaty, Vaclav
    Sarsounova, Zuzana
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN ELECTRONICS, 2020, 31 (24) : 22599 - 22615
  • [23] The effect of gamma-ray irradiation on bulk optical plastic materials
    Václav Prajzler
    Václav Chlupatý
    Zuzana Šaršounová
    Journal of Materials Science: Materials in Electronics, 2020, 31 : 22599 - 22615
  • [24] A RADIATION DETECTOR CONSTRUCTED WITH GSO SCINTILLATOR AND PLASTIC OPTICAL FIBER COMBINATION FOR REMOTE DOSIMETRY OF GAMMA-RAY FIELDS
    Seo, Min Woo
    Park, Jae Woo
    NUCLEAR TECHNOLOGY, 2009, 168 (03) : 938 - 942
  • [25] PHOTOGRAPHIC X-RAY AND GAMMA-RAY DOSIMETRY
    EHRLICH, M
    FITCH, SH
    NUCLEONICS, 1951, 9 (03): : 5 - 17
  • [26] Application of bistable optical device in fiber-optical sensor
    Yang, Qimin
    Zhong, Liyun
    Zhang, Wenbi
    Wang, Chongzhen
    Jiguang Zazhi/Laser Journal, 1996, 17 (03): : 137 - 140
  • [27] BASIS OF X-RAY AND GAMMA-RAY DOSIMETRY
    DAY, MJ
    PHYSICS IN MEDICINE AND BIOLOGY, 1969, 14 (01): : 153 - &
  • [28] Development of a neutron and gamma-ray flux distribution measurement system with scintillator and optical fiber combination
    Mori, C
    Uritani, A
    Iguchi, T
    Hayashi, S
    Kobayashi, H
    Takami, Y
    Kimura, I
    Katagiri, M
    Kakuta, T
    REACTOR DOSIMETRY: RADIATION METROLOGY AND ASSESSMENT, 2001, 1398 : 769 - 774
  • [29] Use of fiber-optical reflected sensor for rapid measurement of aluminum in drinking water
    Huang, Xiao-Chen
    Wei, He-Ping
    Zhongguo Jishui Paishui/China Water & Wastewater, 2001, 17 (12):
  • [30] SIMULTANEOUS OPTICAL GAMMA-RAY OBSERVATIONS OF GAMMA-RAY BURSTS
    GREINER, J
    ASTRONOMY FROM WIDE-FIELD IMAGING, 1994, (161): : 57 - 59