A Fiber-Optical Dosimetry Sensor for Gamma-Ray Irradiation Measurement in Biological Applications

被引:1
|
作者
Elsharkawi, Adel Shaaban Awad [1 ,2 ]
Alazab, Huda A. [3 ]
Sayed, Mahmoud [1 ]
Askar, Mostafa A. [4 ]
Abdelrahman, Ibrahim Y. [4 ]
Arafa, Amany A. [1 ]
Saleh, Hassan I. [1 ]
Gomaa, Lotfy R. [5 ]
Du, Yi-Chun [6 ,7 ]
机构
[1] Egyptian Atom Energy Author EAEA, Natl Ctr Radiat Res & Technol NCRRT, Dept Radiat Engn, Cairo 11787, Egypt
[2] Natl Cheng Kung Univ, Adv Optoelect Technol Ctr, Tainan 70101, Taiwan
[3] Egyptian Atom Energy Author, Nucl & Radiol Safety Res Ctr, Cairo, Egypt
[4] Egyptian Atom Energy Author EAEA, Natl Ctr Radiat Res & Technol NCRRT, Radiat Biol Dept, Cairo 11787, Egypt
[5] Banha Univ, Fac Engn Shoubra, Cairo 11672, Egypt
[6] Natl Cheng Kung Univ, Dept Biomed Engn, Tainan 70101, Taiwan
[7] Natl Cheng Kung Univ, Med Device Innovat Ctr, Tainan 70101, Taiwan
来源
BIOSENSORS-BASEL | 2023年 / 13卷 / 12期
关键词
fiber-optical dosimeter (FOD); two-dimensional distribution; in vivo animal models; thermo-luminescence detector; SIO2; OPTICAL-FIBERS; RADIATION-INDUCED ATTENUATION; THERMOLUMINESCENCE RESPONSE; HIGH-ENERGY; PHOTON;
D O I
10.3390/bios13121010
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this paper, we propose a novel fiber-optical dosimetry sensor for radiation measurement in biological applications. A two-dimensional (2D) fiber-optical dosimeter (FOD) for radiation measurement is considered. The sensors are arranged as a 2D array in a tailored holder. This FOD targets accurate industrial and medical applications which seek more tolerant radiation dosimeters. In this paper, the FOD sensors are subjected to gamma-ray radiation facilities from the 137Cs gamma-ray irradiator type for low doses and 60Co gamma-ray irradiator for high doses. For better evaluation of radiation effects on the FOD sample, the measurements are performed using eight sensors (hollow cylinder shape) with two samples in each dose. The sensors were measured before and after each irradiation. To the author's knowledge, the measurements of FOD transplanted inside animals are presented for the first time in this paper. A 2D simulation program has been implemented for numerical simulation based on the attenuation factors from the absorbed dose inside the in vivo models. A comparison between the FOD and the standard thermo-luminescence detector is presented based on the test of in vivo animal models. The results indicate that the proposed FOD sensor is more stable and has higher sensitivity.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] CYCLOTRON NEUTRON AND GAMMA-RAY DOSIMETRY FOR ANIMAL IRRADIATION STUDIES
    TOCHILIN, E
    ROSS, SW
    SHUMWAY, BW
    RADIATION RESEARCH, 1954, 1 (06) : 564 - 564
  • [2] CYCLOTRON NEUTRON AND GAMMA-RAY DOSIMETRY FOR ANIMAL IRRADIATION STUDIES
    TOCHILIN, E
    ROSS, SW
    SHUMWAY, BW
    KOHLER, GD
    GOLDEN, R
    RADIATION RESEARCH, 1956, 4 (02) : 158 - 173
  • [3] Fiber-optical biofilm sensor
    不详
    INTERNATIONAL BIODETERIORATION & BIODEGRADATION, 2005, 56 (02) : 124 - 124
  • [4] Effect of Gamma-Ray and Neutron Heating as Interfering Input for the Measurement of Temperature Using Optical Fiber Sensor System
    Blue, Thomas E.
    Wilson, Brandon Augustus
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2017, 64 (11) : 2774 - 2781
  • [5] BASIC GAMMA-RAY DOSIMETRY
    ATTIX, FH
    HEALTH PHYSICS, 1968, 15 (01): : 49 - +
  • [6] SONGS sensor for measurement of GAMMA ray irradiation
    Hsieh Wen-Ching
    Hao-Tien, Daniel Lee
    Xu Hong-Sheng
    HARD X-RAY AND GAMMA-RAY DETECTOR PHYSICS AND PENETRATING RADIATION SYSTEMS VIII, 2006, 6319
  • [7] SELECTION OF FIBER-OPTICAL COMPONENTS FOR TEMPERATURE MEASUREMENT FOR SATELLITE APPLICATIONS
    Putzer, P.
    Chami, N. Kuhenuri
    Koch, A. W.
    Hurni, A.
    Roner, M.
    Obermaier, J.
    Lemke, N. M. K.
    INTERNATIONAL CONFERENCE ON SPACE OPTICS-ICSO 2014, 2014, 10563
  • [8] A NEW CIRCUIT WITH SPECIAL APPLICATIONS IN GAMMA-RAY AND X-RAY DOSIMETRY
    KEMP, LAW
    BRITISH JOURNAL OF RADIOLOGY, 1945, 18 (208): : 107 - 112
  • [9] Manufacture and Characterization of an Extrinsic Elementary Fiber-Optical Sensor for Temperature Measurement
    Trautner, Ralph
    Schmauss, Bernhard
    Shamonin, Mikhail
    TM-TECHNISCHES MESSEN, 2008, 75 (10) : 565 - 570
  • [10] ENHANCED BIOLOGICAL ACTIVITIES OF LAMINARIN DEGRADED BY GAMMA-RAY IRRADIATION
    Choi, Jong-Il
    Kim, Hyun-Joo
    Kim, Jae-Hun
    Lee, Ju-Woon
    JOURNAL OF FOOD BIOCHEMISTRY, 2012, 36 (04) : 465 - 469